<?xml version="1.0" encoding="UTF-8"?>
<!DOCTYPE article PUBLIC "-//NLM//DTD Journal Publishing with OASIS Tables v3.0 20080202//EN" "https://jats.nlm.nih.gov/nlm-dtd/publishing/3.0/journalpub-oasis3.dtd">
<article xmlns:xlink="http://www.w3.org/1999/xlink" xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:oasis="http://docs.oasis-open.org/ns/oasis-exchange/table" xml:lang="en" dtd-version="3.0" article-type="research-article">
  <front>
    <journal-meta><journal-id journal-id-type="publisher">AR</journal-id><journal-title-group>
    <journal-title>Aerosol Research</journal-title>
    <abbrev-journal-title abbrev-type="publisher">AR</abbrev-journal-title><abbrev-journal-title abbrev-type="nlm-ta">Aerosol Research</abbrev-journal-title>
  </journal-title-group><issn pub-type="epub">2940-3391</issn><publisher>
    <publisher-name>Copernicus Publications</publisher-name>
    <publisher-loc>Göttingen, Germany</publisher-loc>
  </publisher></journal-meta>
    <article-meta>
      <article-id pub-id-type="doi">10.5194/ar-4-121-2026</article-id><title-group><article-title>Evaluation of mass measurement techniques for soot with different size distributions and OC <inline-formula><mml:math id="M1" display="inline"><mml:mo>/</mml:mo></mml:math></inline-formula> TC contents</article-title><alt-title>Evaluation of soot mass measurement techniques</alt-title>
      </title-group>
      <contrib-group>
        <contrib contrib-type="author" corresp="yes" rid="aff1">
          <name><surname>Sagot</surname><given-names>Benoît</given-names></name>
          <email>benoit.sagot@estaca.fr</email>
        <ext-link>https://orcid.org/0000-0001-8957-9503</ext-link></contrib>
        <contrib contrib-type="author" corresp="no" rid="aff2">
          <name><surname>Pailloux</surname><given-names>Guillaume</given-names></name>
          
        </contrib>
        <contrib contrib-type="author" corresp="no" rid="aff2">
          <name><surname>Kort</surname><given-names>Amel</given-names></name>
          
        </contrib>
        <aff id="aff1"><label>1</label><institution>ESTACA, ESTACA'Lab – Paris Saclay, Montigny-Le-Bretonneux, 78180, France</institution>
        </aff>
        <aff id="aff2"><label>2</label><institution>Autorité de Sûreté Nucléaire et de Radioprotection (ASNR), PSN-RES/SCA/LPMA, 91400, Saclay, France</institution>
        </aff>
      </contrib-group>
      <author-notes><corresp id="corr1">Benoît Sagot (benoit.sagot@estaca.fr)</corresp></author-notes><pub-date><day>3</day><month>March</month><year>2026</year></pub-date>
      
      <volume>4</volume>
      <issue>1</issue>
      <fpage>121</fpage><lpage>131</lpage>
      <history>
        <date date-type="received"><day>19</day><month>May</month><year>2025</year></date>
           <date date-type="rev-request"><day>28</day><month>May</month><year>2025</year></date>
           <date date-type="rev-recd"><day>30</day><month>January</month><year>2026</year></date>
           <date date-type="accepted"><day>10</day><month>February</month><year>2026</year></date>
      </history>
      <permissions>
        <copyright-statement>Copyright: © 2026 Benoît Sagot et al.</copyright-statement>
        <copyright-year>2026</copyright-year>
      <license license-type="open-access"><license-p>This work is licensed under the Creative Commons Attribution 4.0 International License. To view a copy of this licence, visit <ext-link ext-link-type="uri" xlink:href="https://creativecommons.org/licenses/by/4.0/">https://creativecommons.org/licenses/by/4.0/</ext-link></license-p></license></permissions><self-uri xlink:href="https://ar.copernicus.org/articles/4/121/2026/ar-4-121-2026.html">This article is available from https://ar.copernicus.org/articles/4/121/2026/ar-4-121-2026.html</self-uri><self-uri xlink:href="https://ar.copernicus.org/articles/4/121/2026/ar-4-121-2026.pdf">The full text article is available as a PDF file from https://ar.copernicus.org/articles/4/121/2026/ar-4-121-2026.pdf</self-uri>
      <abstract><title>Abstract</title>

      <p id="d2e112">This study focuses on measuring the mass concentration of soot aggregates generated with a Mini-CAST burner. The experiments were performed in a test bench able to generate soot particles with different size distributions and different organic to total carbon (<inline-formula><mml:math id="M2" display="inline"><mml:mrow class="chem"><mml:mi mathvariant="normal">OC</mml:mi><mml:mo>/</mml:mo><mml:mi mathvariant="normal">TC</mml:mi></mml:mrow></mml:math></inline-formula>) ratios. With this soot production, we assessed the mass concentration measurements obtained with four online instruments, based on different methods: oscillating microbalance, aerosol electrical charging, filter photometry, and aerosol mobility, as well as an offline gravimetric measurement. The <inline-formula><mml:math id="M3" display="inline"><mml:mrow class="chem"><mml:mi mathvariant="normal">OC</mml:mi><mml:mo>/</mml:mo><mml:mi mathvariant="normal">TC</mml:mi></mml:mrow></mml:math></inline-formula> ratio was determined by the thermal–optical method. The findings demonstrate that the oscillating microbalance measurements were performed within acceptable limits of 10 % in comparison to the gravimetric measurements, over a wide range of <inline-formula><mml:math id="M4" display="inline"><mml:mrow class="chem"><mml:mi mathvariant="normal">OC</mml:mi><mml:mo>/</mml:mo><mml:mi mathvariant="normal">TC</mml:mi></mml:mrow></mml:math></inline-formula> ratio, mass concentration, and size distribution. The oscillating microbalance measurements were therefore considered to be the reference. The mass concentration measurement based on the aerosol electrical charging is calibrated for a reference size distribution, and we suggested a correction of the mass concentration measurement based on the aerosol Fuchs active surface, which proved to be efficient within the limits of this study. Finally, we confirmed that the mass concentration measurements obtained with the filter photometry method are <inline-formula><mml:math id="M5" display="inline"><mml:mrow class="chem"><mml:mi mathvariant="normal">OC</mml:mi><mml:mo>/</mml:mo><mml:mi mathvariant="normal">TC</mml:mi></mml:mrow></mml:math></inline-formula> ratio and wavelength dependent, and we were able to establish <inline-formula><mml:math id="M6" display="inline"><mml:mrow class="chem"><mml:mi mathvariant="normal">OC</mml:mi><mml:mo>/</mml:mo><mml:mi mathvariant="normal">TC</mml:mi></mml:mrow></mml:math></inline-formula> limits for the overall mass concentration evaluation with the infrared and ultraviolet wavelengths.</p>
  </abstract>
    </article-meta>
  </front>
<body>
      

<sec id="Ch1.S1" sec-type="intro">
  <label>1</label><title>Introduction</title>
      <p id="d2e184">In the context of studies on airborne dispersion of soot particles emitted during fire scenarios and monitoring and quantification of emissions from thermal engines, it is important to have a robust measurement of the mass concentration of emitted soot. These measurements are needed to assess the consequences of fires in basic nuclear installations (Kort et al., 2022), as soot is responsible for clogging the last containment barrier made by HEPA filters and for the metrology of conventional engine PM emissions (Aakko-Saksa et al., 2022). Dynamic real-time monitoring of mass emissions can be performed using various types of instruments based on different measurement principles, such as the Aethalometer-type  real-time filter photometry  measurement method (MA300), tapered element oscillating microbalance (TEOM), or the electrical-charging-based Pegasor particle sensor (PPS). These instruments allow for the study of aerosols across a wide range of concentrations, from ambient air quality monitoring to highly concentrated exhaust emissions. The quantification performed by the PPS is based on the electrical charge on the surface of aerosols, making it extremely dynamic. However, it requires calibration that primarily depends on the mobility median diameter of the aerosol particle size distribution, measured using a scanning mobility particle sizer (SMPS). Similarly, the Aethalometer is an instrument based on optical transmission through a soot cake collected on a filter, and its mass quantification is influenced by the physical nature of the soot, particularly the elemental carbon to organic carbon ratio. For time-stable emission sources, it is also possible to perform measurements using filter sampling, which allows mass concentration quantification by weighing (gravimetric measurement) and organic carbon to total carbon (<inline-formula><mml:math id="M7" display="inline"><mml:mrow class="chem"><mml:mi mathvariant="normal">OC</mml:mi><mml:mo>/</mml:mo><mml:mi mathvariant="normal">TC</mml:mi></mml:mrow></mml:math></inline-formula>) ratio determination using a Sunset Laboratory analyzer. All these mass concentration measurement techniques, usually used in different contexts, need to be qualified to provide reliable and robust measurements.</p>
      <p id="d2e199">For this purpose, soot was generated by a mini-CAST JING 5201C burner through the combustion of propane. Different studies have demonstrated that this mini-CAST generator can produce soot with a wide range of sizes and properties and is regarded as a relevant tool to produce soot similar to that emitted by different combustion processes, such as aircraft engines (Marhaba et al., 2019) or fire situations (Kort et al., 2021). It has been extensively used for soot characterization and as a time-stable soot production source: by varying the gas flow rates supplied to this generator, it is possible to adjust the mass concentration over a wide range, as well as the particle size distribution and the elemental carbon to organic carbon ratio of the produced soot particles. The concentrations of generated soot are then either collected on a filter for ex situ measurements or diluted using a double-stage ejector-type diluter, such as the Dekati eDiluter, which delivers concentrations compatible with the measurement ranges of the instruments used.</p>
      <p id="d2e202">The mass concentrations evaluated by the online devices (MA300, PPS Pegasor, SMPS) and the offline direct gravimetric measurement were studied as a function of the reference mass concentration evaluated by the TEOM. The evaluation of the <inline-formula><mml:math id="M8" display="inline"><mml:mrow class="chem"><mml:mi mathvariant="normal">OC</mml:mi><mml:mo>/</mml:mo><mml:mi mathvariant="normal">TC</mml:mi></mml:mrow></mml:math></inline-formula> ratio done from the filters and the size distributions of the produced soot particles are also necessary for the interpretation of the instrument responses.</p>
</sec>
<sec id="Ch1.S2">
  <label>2</label><title>Experimental setup</title>
      <p id="d2e225">For this experimental study, we developed a test bench (Fig. 1) dedicated to the mass concentration intercomparison. This setup includes the soot generation source and the mini-CAST, followed by two lines. One line, maintained at 180 °C, is used for filter sampling. This standard method will  initially be regarded as the reference. The other line feeds a dilution system that distributes the diluted and cooled aerosol to various measurement instruments: the TEOM, PPS, MA300, and SMPS. The standard filter sampling reference method will allow for the verification of the diluter performance and the evaluation of losses along the different branches. The sampling system was designed and operated in accordance with ISO 8178 requirements, which specify standardized procedures for measuring exhaust emissions from internal combustion engines with a target temperature of 180 °C for the sampling line and a maximum residence time of 3 <inline-formula><mml:math id="M9" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">s</mml:mi></mml:mrow></mml:math></inline-formula>. With a sampling flow rate of 7.7 <inline-formula><mml:math id="M10" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">L</mml:mi><mml:mspace width="0.125em" linebreak="nobreak"/><mml:msup><mml:mi mathvariant="normal">min</mml:mi><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:msup></mml:mrow></mml:math></inline-formula> and a line length of 1 <inline-formula><mml:math id="M11" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">m</mml:mi></mml:mrow></mml:math></inline-formula> (inner diameter of 6 <inline-formula><mml:math id="M12" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">mm</mml:mi></mml:mrow></mml:math></inline-formula>), the aerosol residence time is approximately 0.22 <inline-formula><mml:math id="M13" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">s</mml:mi></mml:mrow></mml:math></inline-formula>. The following sections detail the operating principles and implementation conditions of each component of this test setup.</p>

      <fig id="F1" specific-use="star"><label>Figure 1</label><caption><p id="d2e279">Configuration of the experimental bench for intercomparison of mass concentration measurements.</p></caption>
        <graphic xlink:href="https://ar.copernicus.org/articles/4/121/2026/ar-4-121-2026-f01.jpg"/>

      </fig>

      <p id="d2e288">The aerosol source is a Mini-CAST 5201C soot generator, which produces polydisperse soot particles by propane combustion. The principle of soot generation by the Mini-CAST involves an axial laminar diffusion flame, which is quenched by a cold, dry nitrogen flow to stop the combustion process and prevent soot oxidation. A rapid dilution with clean, dry air reduces the soot concentration, thereby limiting particle coagulation. By varying the flow rates of fuel, oxidizing air, and mixing nitrogen, it is possible to modify the characteristics of the flame, particularly its temperature, which affects both the quantity and the properties of the produced soot particles (Moore et al., 2014). As in the study by Marhaba et al. (2019), propane flow is maintained at 60 <inline-formula><mml:math id="M14" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">mL</mml:mi><mml:mspace width="0.125em" linebreak="nobreak"/><mml:msup><mml:mi mathvariant="normal">min</mml:mi><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:msup></mml:mrow></mml:math></inline-formula>, nitrogen flow at 0 <inline-formula><mml:math id="M15" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">mL</mml:mi><mml:mspace linebreak="nobreak" width="0.125em"/><mml:msup><mml:mi mathvariant="normal">min</mml:mi><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:msup></mml:mrow></mml:math></inline-formula>, dilution airflow at 20 <inline-formula><mml:math id="M16" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">L</mml:mi><mml:mspace linebreak="nobreak" width="0.125em"/><mml:msup><mml:mi mathvariant="normal">min</mml:mi><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:msup></mml:mrow></mml:math></inline-formula>, and quenching nitrogen flow at 7 <inline-formula><mml:math id="M17" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">L</mml:mi><mml:mspace linebreak="nobreak" width="0.125em"/><mml:msup><mml:mi mathvariant="normal">min</mml:mi><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:msup></mml:mrow></mml:math></inline-formula>. Variations in  soot production were obtained by varying the oxidation airflow rate from 0.9 up to 1.5 <inline-formula><mml:math id="M18" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">L</mml:mi><mml:mspace linebreak="nobreak" width="0.125em"/><mml:msup><mml:mi mathvariant="normal">min</mml:mi><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:msup></mml:mrow></mml:math></inline-formula> (0.9, 1, 1.15, 1.2, 1.25, 1.3, 1.35, and 1.5 <inline-formula><mml:math id="M19" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">L</mml:mi><mml:mspace linebreak="nobreak" width="0.125em"/><mml:msup><mml:mi mathvariant="normal">min</mml:mi><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:msup></mml:mrow></mml:math></inline-formula>). The measurement points with oxidation airflow rate at 1, 1.15, and 1.5 <inline-formula><mml:math id="M20" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">L</mml:mi><mml:mspace width="0.125em" linebreak="nobreak"/><mml:msup><mml:mi mathvariant="normal">min</mml:mi><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:msup></mml:mrow></mml:math></inline-formula> correspond  to the CAST3, CAST2, and CAST1 operating points, respectively, in the study of Marhaba et al. (2019). These specific operating points were also chosen for different studies (Bescond et al., 2016; Ouf et al., 2016). During the tests, stable generation points were sought, and before initiating filter sampling, the stability of the concentration production was ensured through measurements taken with online instruments such as the PPS and TEOM. Each measurement point was repeated three times, and the error bars represent the standard deviation of these measurements.</p>
      <p id="d2e412">A flexible heated line (1 <inline-formula><mml:math id="M21" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">m</mml:mi></mml:mrow></mml:math></inline-formula> long with 6 <inline-formula><mml:math id="M22" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">mm</mml:mi></mml:mrow></mml:math></inline-formula> internal diameter) connects the mini-CAST soot generator to the filter sampler and is maintained at 180 °C. This line is dedicated to sampling on quartz fiber filters (Whatman quartz filter, grade QM-H, diam. 47 <inline-formula><mml:math id="M23" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">mm</mml:mi></mml:mrow></mml:math></inline-formula>) for ex situ gravimetric measurements and for later <inline-formula><mml:math id="M24" display="inline"><mml:mrow class="chem"><mml:mi mathvariant="normal">OC</mml:mi><mml:mo>/</mml:mo><mml:mi mathvariant="normal">TC</mml:mi></mml:mrow></mml:math></inline-formula> analysis. These filters are used for mass quantification of soot concentration during stable generation conditions. Quartz filters are preconditioned by heating at 180 °C in an oven for 1 h to eliminate moisture. They are then weighed and stored with desiccant to prevent reabsorption of humidity. During measurements, the filters are placed in the 47 <inline-formula><mml:math id="M25" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">mm</mml:mi></mml:mrow></mml:math></inline-formula> sampler with a 180 °C-temperature-regulated heating jacket surrounding it. The collected mass is determined using a precision balance (Kern ABT 100-5M). The volume of gas passing through the filter is measured using a Gallus gas volumetric counter (see Fig. 1). Between the mass sampler and this Gallus volumetric counter, a heat exchanger cools the gas down to ambient temperature, maintained at 20 °C in the laboratory. By combining the collected mass with the measured gas volume, the soot mass concentration is calculated. This measurement is referred to as “gravimetric mass concentration” in the study.</p>
      <p id="d2e459">The Sunset Lab OC/EC field instrument (Sunset Laboratory) has been used for the measurement of the <inline-formula><mml:math id="M26" display="inline"><mml:mrow class="chem"><mml:mi mathvariant="normal">OC</mml:mi><mml:mo>/</mml:mo><mml:mi mathvariant="normal">TC</mml:mi></mml:mrow></mml:math></inline-formula> ratio. Filters were analyzed based on the IMPROVE_A thermal protocol (Chow et al., 2001). In this instrument, to separate the organic fraction of carbon (OC) from the elemental fraction (EC), the samples are subjected to various temperature plateaus (up to 850 °C) in a helium inert atmosphere for the OC fraction and in an oxidizing atmosphere for the EC fraction. The formed gases are then transported by the helium flow to a catalytic furnace, where they are oxidized to <inline-formula><mml:math id="M27" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">CO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula>, then reduced to <inline-formula><mml:math id="M28" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">CH</mml:mi><mml:mn mathvariant="normal">4</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> for more accurate measurement by a calibrated flame-ionization detector (FID). A thermal–optical correction is applied to separate OC from EC. <inline-formula><mml:math id="M29" display="inline"><mml:mrow class="chem"><mml:mi mathvariant="normal">OC</mml:mi><mml:mo>/</mml:mo><mml:mi mathvariant="normal">TC</mml:mi></mml:mrow></mml:math></inline-formula> measurements have been performed on quartz fiber filters. Three punches of 1.5 <inline-formula><mml:math id="M30" display="inline"><mml:mrow class="unit"><mml:msup><mml:mi mathvariant="normal">cm</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msup></mml:mrow></mml:math></inline-formula> were analyzed for each sample.</p>
      <p id="d2e519">The second sampling line, after dilution, feeds real-time measurement instruments. The Dekati eDiluter Pro dilution system enables two-stage dilution with a dilution factor set at 100. The first dilution stage is heated, while the second dilution stage operates at room temperature, where the aerosol sample is also cooled in a controlled manner. Both dilution stages are ejector type, with a complementary sweep airflow in the duct. Concentrations downstream of the dilution system are compatible with the measurement ranges of the instruments used: a TEOM for  robust measurement of mass concentration, a PPS, and an MA300 Aethalometer for real-time mass concentration measurement, as well as an SMPS for measurement of particle size distribution. The SMPS is composed of a differential mobility analyzer (DMA 3080, TSI), which provides a mobility diameter size selection of particles, and a condensation particle counter (CNC 3775, TSI).</p>
      <p id="d2e522">The TEOM (Thermo Scientific 1405) can continuously measure the mass of PM accumulating on a filter mounted upon an inertial microbalance using the tapered element oscillating method at its natural frequency (at 200 <inline-formula><mml:math id="M31" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">Hz</mml:mi></mml:mrow></mml:math></inline-formula>). Aerosol is drawn in by a pump connected to the base of the microbalance. Sampled particles retained by the filter increase the mass of the oscillating system, producing a decrease in the natural frequency of vibration. Changes in the frequency of oscillation, which are related to the mass of material accumulating on the filter, are detected in quasi-real-time and converted by a microprocessor into an equivalent PM mass concentration (Allen et al., 1997). The sampled particles are heated at a temperature of 50 °C.</p>
      <p id="d2e533">The PPS is a real-time sensor that can be used to provide the mass and number concentration of aerosols in the exhaust of car engines based on electrical measurement. Figure 2 presents the operating principle of the PPS: the device is supplied with clean, dry compressed air. In the first phase, the clean air is ionized by the corona effect and ejected through an orifice (Ntziachristos et al., 2013). Particles are electrically charged by the binding of ions within a zone isolated by a Faraday cage. Only the small number of ions that charge the particle surface are lost to the sensor outlet, where an electrometer is used to measure the “compensation” electrical current. It is related to the particle number concentration and particle size, and Ntziachristos et al. (2004) demonstrated that this instrument provides a measure of the active surface area of the studied aerosol (Rostedt et al., 2014).</p>

      <fig id="F2"><label>Figure 2</label><caption><p id="d2e539">PPS operating principle.</p></caption>
        <graphic xlink:href="https://ar.copernicus.org/articles/4/121/2026/ar-4-121-2026-f02.png"/>

      </fig>

      <p id="d2e548">The raw current measurement is then used to determine the mass or number concentrations of sampled particles using calibration coefficients dependent on particle size. The remaining free ions with  high electrical mobility are eliminated by an ion trap. In addition, the injector design protects the corona needle, and the charged particles are sensed with no need for contact with the sensor, which can be beneficial in these polluted environments (Maricq, 2013). Despite the PPS's ability to track emissions dynamically (at hertz frequency) under high number and mass concentrations, which can be useful for real-time emission monitoring in fire situations, the PPS mass calibration factor was essentially established on automobile emissions with a relatively limited range of size distribution in number (Ntziachristos et al., 2013) and <inline-formula><mml:math id="M32" display="inline"><mml:mrow class="chem"><mml:mi mathvariant="normal">OC</mml:mi><mml:mo>/</mml:mo><mml:mi mathvariant="normal">TC</mml:mi></mml:mrow></mml:math></inline-formula> ratios which were not indicated in their study.</p>
      <p id="d2e563">The MA300 Aethalometer (AethLabs, San Francisco) is a real-time portable analyzer that uses the filter-based light absorption principle: the mass concentration measurement is based on the optical attenuation ATN of a light beam passing through a cake of particles collected on a filtering fiber tape. The instrument has five analytical channels that operate at different wavelengths (375, 470, 528, 625, and 880 <inline-formula><mml:math id="M33" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">nm</mml:mi></mml:mrow></mml:math></inline-formula>), and the measurement of absorption at 880 <inline-formula><mml:math id="M34" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">nm</mml:mi></mml:mrow></mml:math></inline-formula> is interpreted as black carbon (Hansen et al., 1984). The MA300 draws a controlled flow through the collection spot on the filter tape, and when the light attenuation reaches a threshold value, the tape advances automatically.</p>
      <p id="d2e582">The ATN is defined (Gundel et al., 1984) as ATN <inline-formula><mml:math id="M35" display="inline"><mml:mo>=</mml:mo></mml:math></inline-formula> <inline-formula><mml:math id="M36" display="inline"><mml:mo>-</mml:mo></mml:math></inline-formula>100 <inline-formula><mml:math id="M37" display="inline"><mml:mrow><mml:mo>×</mml:mo><mml:mi>ln⁡</mml:mi><mml:mo>(</mml:mo><mml:mi>I</mml:mi><mml:mo>/</mml:mo><mml:msub><mml:mi>I</mml:mi><mml:mn mathvariant="normal">0</mml:mn></mml:msub><mml:mo>)</mml:mo></mml:mrow></mml:math></inline-formula>, with <inline-formula><mml:math id="M38" display="inline"><mml:mi>I</mml:mi></mml:math></inline-formula> and <inline-formula><mml:math id="M39" display="inline"><mml:mrow><mml:msub><mml:mi>I</mml:mi><mml:mn mathvariant="normal">0</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> being the measured intensity through the loaded spot signal and the reference signal through the empty filter, respectively (see Fig. 3). The instrument measures the transmission of light through the particle-loaded filter, from which the ATN is derived based on its rate of change over time. This attenuation is then converted into an absorption coefficient. Finally, the equivalent black carbon mass concentration is obtained by dividing the absorption coefficient by <inline-formula><mml:math id="M40" display="inline"><mml:mrow><mml:msub><mml:mi mathvariant="italic">σ</mml:mi><mml:mtext>MAC</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula>, the mass absorption coefficient (MAC) specific to black carbon (Drinovec et al., 2015). With this definition and for the 880 <inline-formula><mml:math id="M41" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">nm</mml:mi></mml:mrow></mml:math></inline-formula> wavelength, the deposited equivalent black carbon (eBC) mass concentration is then evaluated as

          <disp-formula id="Ch1.E1" content-type="numbered"><label>1</label><mml:math id="M42" display="block"><mml:mrow><mml:mtext>eBC</mml:mtext><mml:mo>=</mml:mo><mml:mstyle displaystyle="true"><mml:mfrac style="display"><mml:mrow><mml:mi>S</mml:mi><mml:mo>⋅</mml:mo><mml:mo>(</mml:mo><mml:mi mathvariant="normal">Δ</mml:mi><mml:mtext>ATN</mml:mtext><mml:mo>/</mml:mo><mml:mn mathvariant="normal">100</mml:mn><mml:mo>)</mml:mo></mml:mrow><mml:mrow><mml:mi>Q</mml:mi><mml:mo>⋅</mml:mo><mml:msub><mml:mi mathvariant="italic">σ</mml:mi><mml:mtext>MAC</mml:mtext></mml:msub><mml:mo>⋅</mml:mo><mml:msub><mml:mi>C</mml:mi><mml:mtext>ref</mml:mtext></mml:msub><mml:mo>⋅</mml:mo><mml:mo>(</mml:mo><mml:mn mathvariant="normal">1</mml:mn><mml:mo>-</mml:mo><mml:mi>k</mml:mi><mml:mo>⋅</mml:mo><mml:mtext>ATN</mml:mtext><mml:mo>)</mml:mo><mml:mo>⋅</mml:mo><mml:mi mathvariant="normal">Δ</mml:mi><mml:mi>t</mml:mi></mml:mrow></mml:mfrac></mml:mstyle><mml:mo>,</mml:mo></mml:mrow></mml:math></disp-formula>

        where <inline-formula><mml:math id="M43" display="inline"><mml:mi>S</mml:mi></mml:math></inline-formula> is the collection spot area, <inline-formula><mml:math id="M44" display="inline"><mml:mrow><mml:mi mathvariant="normal">Δ</mml:mi><mml:mtext>ATN</mml:mtext></mml:mrow></mml:math></inline-formula> the change in attenuation during interval <inline-formula><mml:math id="M45" display="inline"><mml:mrow><mml:mi mathvariant="normal">Δ</mml:mi><mml:mi>t</mml:mi></mml:mrow></mml:math></inline-formula>, <inline-formula><mml:math id="M46" display="inline"><mml:mi>Q</mml:mi></mml:math></inline-formula> the measured flow rate after accounting for the instrument's internal leakage, <inline-formula><mml:math id="M47" display="inline"><mml:mrow><mml:mi mathvariant="normal">Δ</mml:mi><mml:mi>t</mml:mi></mml:mrow></mml:math></inline-formula> the time interval between two measurements, <inline-formula><mml:math id="M48" display="inline"><mml:mrow><mml:msub><mml:mi>C</mml:mi><mml:mtext>ref</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> the multiple scattering correction factor, and <inline-formula><mml:math id="M49" display="inline"><mml:mi>k</mml:mi></mml:math></inline-formula> a compensation parameter for the filter loading effect correction. Since the airflow is measured downstream of the filter, potential leakage may occur and should be accounted for. However, recent studies using the MA300 and MA350 Aethalometers (Chakraborty et al., 2023; Elomaa et al., 2025) considered these leakages to be negligible, as we did in this study.</p>

      <fig id="F3"><label>Figure 3</label><caption><p id="d2e796">MA300 operating principle with dual-spot concept.</p></caption>
        <graphic xlink:href="https://ar.copernicus.org/articles/4/121/2026/ar-4-121-2026-f03.png"/>

      </fig>

      <p id="d2e806">The filter-based light absorption techniques are subject to measurement artifacts due to scattering on the filter (Weingartner et al., 2003). These empirical parameters are related to the instrument design and filter material (Wu et al., 2024). The <inline-formula><mml:math id="M50" display="inline"><mml:mrow><mml:msub><mml:mi>C</mml:mi><mml:mtext>ref</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> parameter considers a multiple-scattering correction factor, which mainly depends on the properties of the filter substrate and  the optical characteristics of the aerosol deposited on the filter, with no significant spectral dependence (Drinovec et al., 2015). For the MA300 Aethalometer, the sampling filter tape is composed of polytetrafluoroethylene (PTFE), and the manufacturer calibrated a value of <inline-formula><mml:math id="M51" display="inline"><mml:mrow><mml:msub><mml:mi>C</mml:mi><mml:mtext>ref</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> <inline-formula><mml:math id="M52" display="inline"><mml:mo>=</mml:mo></mml:math></inline-formula> 1.3. The mass absorption coefficient <inline-formula><mml:math id="M53" display="inline"><mml:mrow><mml:msub><mml:mi mathvariant="italic">σ</mml:mi><mml:mtext>MAC</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> at 880 <inline-formula><mml:math id="M54" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">nm</mml:mi></mml:mrow></mml:math></inline-formula> wavelength is <inline-formula><mml:math id="M55" display="inline"><mml:mrow><mml:msub><mml:mi mathvariant="italic">σ</mml:mi><mml:mtext>MAC</mml:mtext></mml:msub><mml:mo>=</mml:mo><mml:msub><mml:mi mathvariant="italic">σ</mml:mi><mml:mtext>ATN</mml:mtext></mml:msub><mml:mo>/</mml:mo><mml:msub><mml:mi>C</mml:mi><mml:mtext>ref</mml:mtext></mml:msub><mml:mo>=</mml:mo><mml:mn mathvariant="normal">10.12</mml:mn><mml:mo>/</mml:mo><mml:mn mathvariant="normal">1.3</mml:mn></mml:mrow></mml:math></inline-formula> <inline-formula><mml:math id="M56" display="inline"><mml:mo>=</mml:mo></mml:math></inline-formula> 7.8 <inline-formula><mml:math id="M57" display="inline"><mml:mrow class="unit"><mml:msup><mml:mi mathvariant="normal">m</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msup><mml:mspace width="0.125em" linebreak="nobreak"/><mml:msup><mml:mi mathvariant="normal">g</mml:mi><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:msup></mml:mrow></mml:math></inline-formula>. The specific attenuation cross-section <inline-formula><mml:math id="M58" display="inline"><mml:mrow><mml:msub><mml:mi mathvariant="italic">σ</mml:mi><mml:mtext>ATN</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> is wavelength dependent and was taken from the instrument manufacturer's specifications, with values ranging from <inline-formula><mml:math id="M59" display="inline"><mml:mrow><mml:msub><mml:mi mathvariant="italic">σ</mml:mi><mml:mtext>ATN</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> <inline-formula><mml:math id="M60" display="inline"><mml:mo>=</mml:mo></mml:math></inline-formula> 10.12 <inline-formula><mml:math id="M61" display="inline"><mml:mrow class="unit"><mml:msup><mml:mi mathvariant="normal">m</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msup><mml:mspace width="0.125em" linebreak="nobreak"/><mml:msup><mml:mi mathvariant="normal">g</mml:mi><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:msup></mml:mrow></mml:math></inline-formula> for IR at <inline-formula><mml:math id="M62" display="inline"><mml:mi mathvariant="italic">λ</mml:mi></mml:math></inline-formula> <inline-formula><mml:math id="M63" display="inline"><mml:mo>=</mml:mo></mml:math></inline-formula> 880 <inline-formula><mml:math id="M64" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">nm</mml:mi></mml:mrow></mml:math></inline-formula> up to <inline-formula><mml:math id="M65" display="inline"><mml:mrow><mml:msub><mml:mi mathvariant="italic">σ</mml:mi><mml:mtext>ATN</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> <inline-formula><mml:math id="M66" display="inline"><mml:mo>=</mml:mo></mml:math></inline-formula> 24.069 <inline-formula><mml:math id="M67" display="inline"><mml:mrow class="unit"><mml:msup><mml:mi mathvariant="normal">m</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msup><mml:mspace linebreak="nobreak" width="0.125em"/><mml:msup><mml:mi mathvariant="normal">g</mml:mi><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:msup></mml:mrow></mml:math></inline-formula> for UV at <inline-formula><mml:math id="M68" display="inline"><mml:mi mathvariant="italic">λ</mml:mi></mml:math></inline-formula> <inline-formula><mml:math id="M69" display="inline"><mml:mo>=</mml:mo></mml:math></inline-formula> 375 <inline-formula><mml:math id="M70" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">nm</mml:mi></mml:mrow></mml:math></inline-formula>. The fixed MAC values used in the Aethalometers may not accurately represent the true MAC of the sampled soot aerosol, as MAC can vary with aerosol composition (Chakraborty et al., 2023), including the <inline-formula><mml:math id="M71" display="inline"><mml:mrow class="chem"><mml:mi mathvariant="normal">OC</mml:mi><mml:mo>/</mml:mo><mml:mi mathvariant="normal">TC</mml:mi></mml:mrow></mml:math></inline-formula> ratio, thus introducing uncertainty in the reported eBC concentrations. Sipkens et al. (2025) cite several mechanisms that can explain the variability of MAC between aerosol samples, including intraparticle scattering (the “lensing effect”), the condensation of semi-volatile materials on soot, and variations in particle size. This recent study evaluated operational uncertainties through an intercomparison of five Aethalometers. The results showed that these uncertainties scale with mass concentration, with inter-device multiplicative errors of around 10 % under favorable conditions (Sipkens et al., 2025), such as extended measurement periods or high aerosol loadings. One of the identified drawbacks of Aethalometers is the overestimation of BC concentration on a new filter and the underestimation of it when the loading is high, with the most accurate concentrations being obtained on slightly loaded filters (Arnott et al., 2005; Collaud Coen et al., 2010). Several models have been proposed to correct this loading effect when processing Aethalometers data, such as the Weingartner et al. (2003) and Virkkula et al. (2007) models, which have  most frequently been used for loading effect compensation. Drinovec et al. (2015) developed a real-time method to compensate for nonlinearity with a high time resolution by using a double collection on two spots in parallel at different flow rates. In this method, the <inline-formula><mml:math id="M72" display="inline"><mml:mi>k</mml:mi></mml:math></inline-formula> constant is evaluated for each wavelength, and this so-called “dual-spot technology” permits users to eliminate the data artifact due to filter loading. In this study, the MA300 Aethalometer employs the dual-spot technology to eliminate data distortions caused by filter loading. The sensor applies a variant of the dual-spot correction (Chakraborty et al., 2023; Mendoza et al., 2024), with the parameter <inline-formula><mml:math id="M73" display="inline"><mml:mi>k</mml:mi></mml:math></inline-formula> evaluated using Eq. (2):

          <disp-formula id="Ch1.E2" content-type="numbered"><label>2</label><mml:math id="M74" display="block"><mml:mrow><mml:mi>k</mml:mi><mml:mo>=</mml:mo><mml:mstyle displaystyle="true"><mml:mfrac style="display"><mml:mrow><mml:msub><mml:mtext>eBC</mml:mtext><mml:mi mathvariant="normal">L</mml:mi></mml:msub><mml:mo>-</mml:mo><mml:msub><mml:mtext>eBC</mml:mtext><mml:mi mathvariant="normal">H</mml:mi></mml:msub></mml:mrow><mml:mrow><mml:mo>(</mml:mo><mml:msub><mml:mtext>eBC</mml:mtext><mml:mi mathvariant="normal">L</mml:mi></mml:msub><mml:mo>×</mml:mo><mml:msub><mml:mtext>ATN</mml:mtext><mml:mi mathvariant="normal">H</mml:mi></mml:msub><mml:mo>)</mml:mo><mml:mo>-</mml:mo><mml:mo>(</mml:mo><mml:msub><mml:mtext>eBC</mml:mtext><mml:mi mathvariant="normal">H</mml:mi></mml:msub><mml:mo>×</mml:mo><mml:msub><mml:mtext>ATN</mml:mtext><mml:mi mathvariant="normal">L</mml:mi></mml:msub><mml:mo>)</mml:mo></mml:mrow></mml:mfrac></mml:mstyle><mml:mo>,</mml:mo></mml:mrow></mml:math></disp-formula></p>
      <p id="d2e1139">where L and H represent the low and high flow rates used in this dual-spot technology, respectively.</p>
      <p id="d2e1142">Aethalometers have been used to monitor black carbon concentrations in urban areas (Blanco-Donado et al., 2022), assess biomass burning contribution to emissions in urban areas (Favez et al., 2007), and measure personal exposure in working environments (Gren et al., 2022). However, the ability of Aethalometers to accurately quantify soot emissions remains an active research topic. The recent study by Aakko-Saksa et al. (2022) over a wide ship exhaust test matrix, obtained with different fuels, engines, and emission control devices, showed that measurement with an Aethalometer could lead to overestimation of BC emissions.</p>
</sec>
<sec id="Ch1.S3">
  <label>3</label><title>Results and discussion</title>
      <p id="d2e1153">Figure 4 shows the evolution of the reference (TEOM) mass concentration (left) and the number size distribution measured by the SMPS (right) as a function of oxidation air. When changing the oxidation airflow rate, the main parameter that varies is the fuel–air equivalence ratio <inline-formula><mml:math id="M75" display="inline"><mml:mi mathvariant="normal">Φ</mml:mi></mml:math></inline-formula>, describing the flame in terms of fuel-lean (<inline-formula><mml:math id="M76" display="inline"><mml:mrow><mml:mi mathvariant="normal">Φ</mml:mi><mml:mo>&lt;</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:math></inline-formula>), stoichiometric (<inline-formula><mml:math id="M77" display="inline"><mml:mrow><mml:mi mathvariant="normal">Φ</mml:mi><mml:mo>=</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:math></inline-formula>), and fuel-rich (<inline-formula><mml:math id="M78" display="inline"><mml:mrow><mml:mi mathvariant="normal">Φ</mml:mi><mml:mo>&gt;</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:math></inline-formula>) conditions (Marhaba et al., 2019).</p>

      <fig id="F4" specific-use="star"><label>Figure 4</label><caption><p id="d2e1201">Evolution of the reference (TEOM) mass concentration (left) and the number size distribution (right) as a function of oxidation air.</p></caption>
        <graphic xlink:href="https://ar.copernicus.org/articles/4/121/2026/ar-4-121-2026-f04.png"/>

      </fig>

<table-wrap id="T1" specific-use="star"><label>Table 1</label><caption><p id="d2e1213">Main characteristics of the number size distributions for each of the operating points studied.</p></caption><oasis:table frame="topbot"><oasis:tgroup cols="5">
     <oasis:colspec colnum="1" colname="col1" align="left"/>
     <oasis:colspec colnum="2" colname="col2" align="left"/>
     <oasis:colspec colnum="3" colname="col3" align="left"/>
     <oasis:colspec colnum="4" colname="col4" align="left"/>
     <oasis:colspec colnum="5" colname="col5" align="right"/>
     <oasis:thead>
       <oasis:row>
         <oasis:entry colname="col1">Oxidation air</oasis:entry>
         <oasis:entry colname="col2">Nature of the</oasis:entry>
         <oasis:entry colname="col3">Mode 1 (<inline-formula><mml:math id="M79" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">nm</mml:mi></mml:mrow></mml:math></inline-formula>)</oasis:entry>
         <oasis:entry colname="col4">Mode 2 (<inline-formula><mml:math id="M80" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">nm</mml:mi></mml:mrow></mml:math></inline-formula>)</oasis:entry>
         <oasis:entry colname="col5">Number median</oasis:entry>
       </oasis:row>
       <oasis:row rowsep="1">
         <oasis:entry colname="col1">(<inline-formula><mml:math id="M81" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">L</mml:mi><mml:mspace linebreak="nobreak" width="0.125em"/><mml:msup><mml:mi mathvariant="normal">min</mml:mi><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:msup></mml:mrow></mml:math></inline-formula>)</oasis:entry>
         <oasis:entry colname="col2">distribution</oasis:entry>
         <oasis:entry colname="col3"/>
         <oasis:entry colname="col4"/>
         <oasis:entry colname="col5">diameter (<inline-formula><mml:math id="M82" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">nm</mml:mi></mml:mrow></mml:math></inline-formula>)</oasis:entry>
       </oasis:row>
     </oasis:thead>
     <oasis:tbody>
       <oasis:row>
         <oasis:entry colname="col1">0.9</oasis:entry>
         <oasis:entry colname="col2">monomodal</oasis:entry>
         <oasis:entry colname="col3">24.5 <inline-formula><mml:math id="M83" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">nm</mml:mi></mml:mrow></mml:math></inline-formula> – 100 %</oasis:entry>
         <oasis:entry colname="col4">(–)</oasis:entry>
         <oasis:entry colname="col5">23.3</oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1">1</oasis:entry>
         <oasis:entry colname="col2">bimodal</oasis:entry>
         <oasis:entry colname="col3">33.3 <inline-formula><mml:math id="M84" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">nm</mml:mi></mml:mrow></mml:math></inline-formula> – 93 %</oasis:entry>
         <oasis:entry colname="col4">90.5 <inline-formula><mml:math id="M85" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">nm</mml:mi></mml:mrow></mml:math></inline-formula> – 7 %</oasis:entry>
         <oasis:entry colname="col5">33.4</oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1">1.15</oasis:entry>
         <oasis:entry colname="col2">bimodal</oasis:entry>
         <oasis:entry colname="col3">49.9 <inline-formula><mml:math id="M86" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">nm</mml:mi></mml:mrow></mml:math></inline-formula> – 92 %</oasis:entry>
         <oasis:entry colname="col4">126.6 <inline-formula><mml:math id="M87" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">nm</mml:mi></mml:mrow></mml:math></inline-formula> – 8 %</oasis:entry>
         <oasis:entry colname="col5">51.4</oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1">1.2</oasis:entry>
         <oasis:entry colname="col2">bimodal</oasis:entry>
         <oasis:entry colname="col3">29.8 <inline-formula><mml:math id="M88" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">nm</mml:mi></mml:mrow></mml:math></inline-formula> – 9 %</oasis:entry>
         <oasis:entry colname="col4">64.7 <inline-formula><mml:math id="M89" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">nm</mml:mi></mml:mrow></mml:math></inline-formula> – 91 %</oasis:entry>
         <oasis:entry colname="col5">59.4</oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1">1.25</oasis:entry>
         <oasis:entry colname="col2">bimodal</oasis:entry>
         <oasis:entry colname="col3">31 <inline-formula><mml:math id="M90" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">nm</mml:mi></mml:mrow></mml:math></inline-formula> – 25 %</oasis:entry>
         <oasis:entry colname="col4">93.7 <inline-formula><mml:math id="M91" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">nm</mml:mi></mml:mrow></mml:math></inline-formula> – 75 %</oasis:entry>
         <oasis:entry colname="col5">73.7</oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1">1.3</oasis:entry>
         <oasis:entry colname="col2">bimodal</oasis:entry>
         <oasis:entry colname="col3">26 <inline-formula><mml:math id="M92" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">nm</mml:mi></mml:mrow></mml:math></inline-formula> – 13 %</oasis:entry>
         <oasis:entry colname="col4">105.2 <inline-formula><mml:math id="M93" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">nm</mml:mi></mml:mrow></mml:math></inline-formula> – 87 %</oasis:entry>
         <oasis:entry colname="col5">94.7</oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1">1.35</oasis:entry>
         <oasis:entry colname="col2">monomodal</oasis:entry>
         <oasis:entry colname="col3">(–)</oasis:entry>
         <oasis:entry colname="col4">113 <inline-formula><mml:math id="M94" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">nm</mml:mi></mml:mrow></mml:math></inline-formula> – 100 %</oasis:entry>
         <oasis:entry colname="col5">109.4</oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1">1.5</oasis:entry>
         <oasis:entry colname="col2">monomodal</oasis:entry>
         <oasis:entry colname="col3">(–)</oasis:entry>
         <oasis:entry colname="col4">117.3 <inline-formula><mml:math id="M95" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">nm</mml:mi></mml:mrow></mml:math></inline-formula> – 100 %</oasis:entry>
         <oasis:entry colname="col5">113.4</oasis:entry>
       </oasis:row>
     </oasis:tbody>
   </oasis:tgroup></oasis:table></table-wrap>

      <p id="d2e1563">For oxidation air of 0.9 <inline-formula><mml:math id="M96" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">L</mml:mi><mml:mspace linebreak="nobreak" width="0.125em"/><mml:msup><mml:mi mathvariant="normal">min</mml:mi><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:msup></mml:mrow></mml:math></inline-formula>, the size distribution of generated soot particles is monomodal with a number median diameter of 23.3 <inline-formula><mml:math id="M97" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">nm</mml:mi></mml:mrow></mml:math></inline-formula> and the lowest mass concentration of 5.44 <inline-formula><mml:math id="M98" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">mg</mml:mi><mml:mspace width="0.125em" linebreak="nobreak"/><mml:msup><mml:mi mathvariant="normal">m</mml:mi><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">3</mml:mn></mml:mrow></mml:msup></mml:mrow></mml:math></inline-formula>. Moore et al. (2014) showed that by continuously increasing the oxidation airflow rate, the volumetric soot production reaches a maximum at a value close to 1.3 <inline-formula><mml:math id="M99" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">L</mml:mi><mml:mspace linebreak="nobreak" width="0.125em"/><mml:msup><mml:mi mathvariant="normal">min</mml:mi><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:msup></mml:mrow></mml:math></inline-formula> when the adiabatic temperature of the flame reaches its maximum, with a strong impact on the <inline-formula><mml:math id="M100" display="inline"><mml:mrow class="chem"><mml:mi mathvariant="normal">OC</mml:mi><mml:mo>/</mml:mo><mml:mi mathvariant="normal">TC</mml:mi></mml:mrow></mml:math></inline-formula>  ratio. In our experiments, intermediate values of the oxidation air were thus added. When increasing the oxidation airflow rate, the produced mass concentration increases up to a maximum of 106.39 <inline-formula><mml:math id="M101" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">mg</mml:mi><mml:mspace width="0.125em" linebreak="nobreak"/><mml:msup><mml:mi mathvariant="normal">m</mml:mi><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">3</mml:mn></mml:mrow></mml:msup></mml:mrow></mml:math></inline-formula> for  generated soot, corresponding to an oxidation airflow rate of 1.3 <inline-formula><mml:math id="M102" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">L</mml:mi><mml:mspace linebreak="nobreak" width="0.125em"/><mml:msup><mml:mi mathvariant="normal">min</mml:mi><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:msup></mml:mrow></mml:math></inline-formula>. For this generation point, a bimodal size distribution is obtained. For higher-oxidation air, a decrease in the mass concentration is then observed. When reaching 1.5 <inline-formula><mml:math id="M103" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">L</mml:mi><mml:mspace linebreak="nobreak" width="0.125em"/><mml:msup><mml:mi mathvariant="normal">min</mml:mi><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:msup></mml:mrow></mml:math></inline-formula>, the size distribution becomes monomodal again, with the highest modal median diameter of 113.4 <inline-formula><mml:math id="M104" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">nm</mml:mi></mml:mrow></mml:math></inline-formula> and a mass concentration of 85.68 <inline-formula><mml:math id="M105" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">mg</mml:mi><mml:mspace width="0.125em" linebreak="nobreak"/><mml:msup><mml:mi mathvariant="normal">m</mml:mi><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">3</mml:mn></mml:mrow></mml:msup></mml:mrow></mml:math></inline-formula>. The measured particle size distributions were fitted with the sum of two lognormal distributions that correspond to an ultrafine and a fine mode. We describe in Table 1 the nature of the distribution and report, for each operating point, the median diameters of the two modes and their respective intensities expressed as a percentage. We also indicate the number median diameter of the measured distribution.</p>
      <p id="d2e1714">Figure 5 shows a parity curve of the mass concentrations measured by the TEOM as a function of the gravimetric reference measurements. Over a 2-decade-long mass concentration range, mass concentrations measured by the TEOM remain within a 10 % interval of the gravimetric reference for all eight tested oxidation airflow rates (values indicated next to each data point, in <inline-formula><mml:math id="M106" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">L</mml:mi><mml:mspace width="0.125em" linebreak="nobreak"/><mml:msup><mml:mi mathvariant="normal">min</mml:mi><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:msup></mml:mrow></mml:math></inline-formula>). Based on ISO 16450, we evaluated the slope and offset of the orthogonal assessment. The linear regression established between the reference and tested measurements satisfies the ISO 16450 validation criteria, with the slope <inline-formula><mml:math id="M107" display="inline"><mml:mi>b</mml:mi></mml:math></inline-formula> statistically compatible with unity (<inline-formula><mml:math id="M108" display="inline"><mml:mrow><mml:mo>|</mml:mo><mml:mi>b</mml:mi><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn><mml:mo>|</mml:mo><mml:mo>&lt;</mml:mo><mml:mn mathvariant="normal">2</mml:mn><mml:msub><mml:mi>u</mml:mi><mml:mi>b</mml:mi></mml:msub></mml:mrow></mml:math></inline-formula>) and the intercept  close to zero and statistically compatible with it (<inline-formula><mml:math id="M109" display="inline"><mml:mrow><mml:mo>|</mml:mo><mml:mi>a</mml:mi><mml:mo>|</mml:mo><mml:mo>&lt;</mml:mo><mml:mn mathvariant="normal">2</mml:mn><mml:msub><mml:mi>u</mml:mi><mml:mi>a</mml:mi></mml:msub></mml:mrow></mml:math></inline-formula>), where <inline-formula><mml:math id="M110" display="inline"><mml:mrow><mml:msub><mml:mi>u</mml:mi><mml:mi>b</mml:mi></mml:msub></mml:mrow></mml:math></inline-formula> and <inline-formula><mml:math id="M111" display="inline"><mml:mrow><mml:msub><mml:mi>u</mml:mi><mml:mi>a</mml:mi></mml:msub></mml:mrow></mml:math></inline-formula> are the standard uncertainties associated with the slope and intercept, respectively. Therefore, we have established the equivalence between the TEOM and the gravimetric measurement. This shows that the measurement protocol, including the 180 °C sampling line for the standard filter method and the dilution upstream of the tested instruments, does not significantly affect the mass measurements in either branch of the experiment. Finally, we concluded that the TEOM should be considered  the reference measurement, being online in the exact same conditions downstream of the dilution system. For this uncertainty evaluation, we followed ISO 15767 to assess the uncertainty related to weighing; evaluated the uncertainty on the sampled volume; and applied uncertainty propagation to estimate the overall uncertainty, which combines measurement uncertainty with the uncertainty associated with repeatability based on the three repetitions. The error bars shown in Fig. 5 for gravimetric mass concentration result from this analysis.</p>

      <fig id="F5"><label>Figure 5</label><caption><p id="d2e1812">Parity curve of measured TEOM mass concentrations as a function of the gravimetric reference measurements, with the corresponding interpolation.</p></caption>
        <graphic xlink:href="https://ar.copernicus.org/articles/4/121/2026/ar-4-121-2026-f05.png"/>

      </fig>

      <fig id="F6" specific-use="star"><label>Figure 6</label><caption><p id="d2e1823">Mass concentrations measured by the PPS as a function of the TEOM reference measurements (left) and ratio of mass concentration measured by PPS and TEOM as a function of the median diameter (right).</p></caption>
        <graphic xlink:href="https://ar.copernicus.org/articles/4/121/2026/ar-4-121-2026-f06.png"/>

      </fig>

      <p id="d2e1832">Figure 6 (left) shows the mass concentrations measured by the PPS as a function of those measured by the TEOM for soot produced with the different oxidation airflow rates tested. Figure 6 (right) shows the evolution of the mass concentration ratio measured by the PPS and by the TEOM as a function of the SMPS-measured number median diameter. This ratio logically increases as the median diameter decreases. Indeed, the PPS estimates the particle mass based on its active surface area (Ntziachristos et al., 2004). For spherical particles with a constant diameter, the mass is proportional to the cube of the particle diameter, while the surface area scales with the square of the diameter, resulting in a surface to mass ratio that varies as <inline-formula><mml:math id="M112" display="inline"><mml:mrow class="chem"><mml:mn mathvariant="normal">1</mml:mn><mml:mo>/</mml:mo><mml:mi mathvariant="normal">diameter</mml:mi></mml:mrow></mml:math></inline-formula>. With the calibration performed on polydisperse soot aerosol produced by an engine, the mass is correctly estimated for median diameters close to 80 <inline-formula><mml:math id="M113" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">nm</mml:mi></mml:mrow></mml:math></inline-formula>.</p>
      <p id="d2e1856">The raw PPS measurement becomes reliable for soot generated with an oxidation airflow rate in the limited range of 1.3 to 1.5 <inline-formula><mml:math id="M114" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">L</mml:mi><mml:mspace width="0.125em" linebreak="nobreak"/><mml:msup><mml:mi mathvariant="normal">min</mml:mi><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:msup></mml:mrow></mml:math></inline-formula>, where the mass concentration ratio between the PPS and the TEOM reference method remains nearly constant and close to 1, regardless of the measured median diameter. The mass concentration <inline-formula><mml:math id="M115" display="inline"><mml:mrow><mml:msub><mml:mi>C</mml:mi><mml:mrow><mml:mi mathvariant="normal">m</mml:mi><mml:mo>,</mml:mo><mml:mtext>PPS  raw</mml:mtext></mml:mrow></mml:msub></mml:mrow></mml:math></inline-formula> results have been corrected using Eq. (3) (Pandis et al., 1991):

          <disp-formula id="Ch1.E3" content-type="numbered"><label>3</label><mml:math id="M116" display="block"><mml:mrow><mml:msub><mml:mi>C</mml:mi><mml:mrow><mml:mi mathvariant="normal">m</mml:mi><mml:mo>,</mml:mo><mml:mtext>PPS  corrected</mml:mtext></mml:mrow></mml:msub><mml:mo>=</mml:mo><mml:msub><mml:mi>C</mml:mi><mml:mrow><mml:mi mathvariant="normal">m</mml:mi><mml:mo>,</mml:mo><mml:mtext>PPS  raw</mml:mtext></mml:mrow></mml:msub><mml:msup><mml:mfenced open="(" close=")"><mml:mstyle displaystyle="true"><mml:mfrac style="display"><mml:mrow><mml:msub><mml:mi>d</mml:mi><mml:mrow><mml:mi mathvariant="normal">s</mml:mi><mml:mo>,</mml:mo><mml:mtext>Fuchs</mml:mtext></mml:mrow></mml:msub></mml:mrow><mml:mrow><mml:msub><mml:mi>d</mml:mi><mml:mn mathvariant="normal">0</mml:mn></mml:msub></mml:mrow></mml:mfrac></mml:mstyle></mml:mfenced><mml:mrow><mml:mi>x</mml:mi><mml:mo>(</mml:mo><mml:msub><mml:mi>d</mml:mi><mml:mi mathvariant="normal">p</mml:mi></mml:msub><mml:mo>)</mml:mo></mml:mrow></mml:msup><mml:mo>.</mml:mo></mml:mrow></mml:math></disp-formula></p>

<table-wrap id="T2" specific-use="star"><label>Table 2</label><caption><p id="d2e1958">Properties, true density, and effective density <inline-formula><mml:math id="M117" display="inline"><mml:mrow><mml:msub><mml:mi mathvariant="italic">ρ</mml:mi><mml:mrow><mml:mi mathvariant="normal">eff</mml:mi><mml:mo>,</mml:mo><mml:mn mathvariant="normal">100</mml:mn></mml:mrow></mml:msub></mml:mrow></mml:math></inline-formula> of considered emitted soot particles.</p></caption><oasis:table frame="topbot"><oasis:tgroup cols="5">
     <oasis:colspec colnum="1" colname="col1" align="left"/>
     <oasis:colspec colnum="2" colname="col2" align="right"/>
     <oasis:colspec colnum="3" colname="col3" align="right"/>
     <oasis:colspec colnum="4" colname="col4" align="right"/>
     <oasis:colspec colnum="5" colname="col5" align="right"/>
     <oasis:thead>
       <oasis:row>
         <oasis:entry colname="col1">Oxidation air</oasis:entry>
         <oasis:entry colname="col2"><inline-formula><mml:math id="M118" display="inline"><mml:mrow class="chem"><mml:mi mathvariant="normal">OC</mml:mi><mml:mo>/</mml:mo><mml:mi mathvariant="normal">TC</mml:mi></mml:mrow></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col3"><inline-formula><mml:math id="M119" display="inline"><mml:mrow><mml:msub><mml:mi>d</mml:mi><mml:mrow><mml:mi mathvariant="normal">s</mml:mi><mml:mo>,</mml:mo><mml:mi mathvariant="normal">Fuchs</mml:mi></mml:mrow></mml:msub></mml:mrow></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col4">True density (<inline-formula><mml:math id="M120" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">kg</mml:mi><mml:mspace width="0.125em" linebreak="nobreak"/><mml:msup><mml:mi mathvariant="normal">m</mml:mi><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">3</mml:mn></mml:mrow></mml:msup></mml:mrow></mml:math></inline-formula>),</oasis:entry>
         <oasis:entry colname="col5"><inline-formula><mml:math id="M121" display="inline"><mml:mrow><mml:msub><mml:mi mathvariant="italic">ρ</mml:mi><mml:mrow><mml:mtext>eff</mml:mtext><mml:mo>,</mml:mo><mml:mn mathvariant="normal">100</mml:mn></mml:mrow></mml:msub></mml:mrow></mml:math></inline-formula> (<inline-formula><mml:math id="M122" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">kg</mml:mi><mml:mspace linebreak="nobreak" width="0.125em"/><mml:msup><mml:mi mathvariant="normal">m</mml:mi><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">3</mml:mn></mml:mrow></mml:msup></mml:mrow></mml:math></inline-formula>),</oasis:entry>
       </oasis:row>
       <oasis:row rowsep="1">
         <oasis:entry colname="col1">(<inline-formula><mml:math id="M123" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">L</mml:mi><mml:mspace width="0.125em" linebreak="nobreak"/><mml:msup><mml:mi mathvariant="normal">min</mml:mi><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:msup></mml:mrow></mml:math></inline-formula>)</oasis:entry>
         <oasis:entry colname="col2">(%)</oasis:entry>
         <oasis:entry colname="col3">(<inline-formula><mml:math id="M124" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">nm</mml:mi></mml:mrow></mml:math></inline-formula>)</oasis:entry>
         <oasis:entry colname="col4">calculated with Eq. (4)</oasis:entry>
         <oasis:entry colname="col5">calculated with Eq. (6)</oasis:entry>
       </oasis:row>
     </oasis:thead>
     <oasis:tbody>
       <oasis:row>
         <oasis:entry colname="col1">0.9</oasis:entry>
         <oasis:entry colname="col2">68.2</oasis:entry>
         <oasis:entry colname="col3">28</oasis:entry>
         <oasis:entry colname="col4">1420</oasis:entry>
         <oasis:entry colname="col5">1382</oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1">1</oasis:entry>
         <oasis:entry colname="col2">56.7</oasis:entry>
         <oasis:entry colname="col3">42</oasis:entry>
         <oasis:entry colname="col4">1476</oasis:entry>
         <oasis:entry colname="col5">1306</oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1">1.15</oasis:entry>
         <oasis:entry colname="col2">46.0</oasis:entry>
         <oasis:entry colname="col3">62</oasis:entry>
         <oasis:entry colname="col4">1533</oasis:entry>
         <oasis:entry colname="col5">1235</oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1">1.2</oasis:entry>
         <oasis:entry colname="col2">43.3</oasis:entry>
         <oasis:entry colname="col3">71</oasis:entry>
         <oasis:entry colname="col4">1548</oasis:entry>
         <oasis:entry colname="col5">1217</oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1">1.25</oasis:entry>
         <oasis:entry colname="col2">37.7</oasis:entry>
         <oasis:entry colname="col3">83</oasis:entry>
         <oasis:entry colname="col4">1580</oasis:entry>
         <oasis:entry colname="col5">1180</oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1">1.3</oasis:entry>
         <oasis:entry colname="col2">24.3</oasis:entry>
         <oasis:entry colname="col3">97</oasis:entry>
         <oasis:entry colname="col4">1662</oasis:entry>
         <oasis:entry colname="col5">1092</oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1">1.35</oasis:entry>
         <oasis:entry colname="col2">22.7</oasis:entry>
         <oasis:entry colname="col3">110</oasis:entry>
         <oasis:entry colname="col4">1672</oasis:entry>
         <oasis:entry colname="col5">1081</oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1">1.5</oasis:entry>
         <oasis:entry colname="col2">6.2</oasis:entry>
         <oasis:entry colname="col3">113</oasis:entry>
         <oasis:entry colname="col4">1787</oasis:entry>
         <oasis:entry colname="col5">972</oasis:entry>
       </oasis:row>
     </oasis:tbody>
   </oasis:tgroup></oasis:table></table-wrap>

      <p id="d2e2278">Here, <inline-formula><mml:math id="M125" display="inline"><mml:mrow><mml:msub><mml:mi>d</mml:mi><mml:mrow><mml:mi mathvariant="normal">s</mml:mi><mml:mo>,</mml:mo><mml:mtext>Fuchs</mml:mtext></mml:mrow></mml:msub></mml:mrow></mml:math></inline-formula> is the diameter of the Fuchs active surface, evaluated from the size distribution for each measurement point (evaluated values are reported in Table 2), <inline-formula><mml:math id="M126" display="inline"><mml:mrow><mml:mi>x</mml:mi><mml:mo>(</mml:mo><mml:msub><mml:mi>d</mml:mi><mml:mi mathvariant="normal">p</mml:mi></mml:msub><mml:mo>)</mml:mo><mml:mo>=</mml:mo><mml:mn mathvariant="normal">1.39</mml:mn></mml:mrow></mml:math></inline-formula> in the transition regime (30 to 150 <inline-formula><mml:math id="M127" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">nm</mml:mi></mml:mrow></mml:math></inline-formula>) (Jung and Kittelson, 2005), and <inline-formula><mml:math id="M128" display="inline"><mml:mrow><mml:msub><mml:mi>d</mml:mi><mml:mn mathvariant="normal">0</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> is a reference diameter taken arbitrarily equal to 100 <inline-formula><mml:math id="M129" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">nm</mml:mi></mml:mrow></mml:math></inline-formula>.</p>
      <p id="d2e2345">We also calculated the mass concentration based on the number size distribution measured by the SMPS. For this evaluation, we initially considered a constant so-called “true density”, independent of the particle mobility diameter but varying with the <inline-formula><mml:math id="M130" display="inline"><mml:mrow class="chem"><mml:mi mathvariant="normal">OC</mml:mi><mml:mo>/</mml:mo><mml:mi mathvariant="normal">TC</mml:mi></mml:mrow></mml:math></inline-formula> ratio and therefore dependent on the selected operating point of the Mini-CAST. Indeed, as reported by several studies (Ouf et al., 2019; Park et al., 2004), the density of combustion soot particles decreases when the organic fraction increases from the value of the elemental carbon density <inline-formula><mml:math id="M131" display="inline"><mml:mrow><mml:msub><mml:mi mathvariant="italic">ρ</mml:mi><mml:mtext>EC</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> (close to 2000 <inline-formula><mml:math id="M132" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">kg</mml:mi><mml:mspace width="0.125em" linebreak="nobreak"/><mml:msup><mml:mi mathvariant="normal">m</mml:mi><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">3</mml:mn></mml:mrow></mml:msup></mml:mrow></mml:math></inline-formula>) down to the value of the organic carbon density <inline-formula><mml:math id="M133" display="inline"><mml:mrow><mml:msub><mml:mi mathvariant="italic">ρ</mml:mi><mml:mtext>OC</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula>. For diesel soot particles, Park et al. (2004) proposed the evaluation of the true aggregate density through a mixing law based on the mass fraction of organic carbon (<inline-formula><mml:math id="M134" display="inline"><mml:mrow><mml:mi>x</mml:mi><mml:mo>=</mml:mo><mml:msub><mml:mi>M</mml:mi><mml:mtext>OC</mml:mtext></mml:msub><mml:mo>/</mml:mo><mml:mo>(</mml:mo><mml:msub><mml:mi>M</mml:mi><mml:mtext>OC</mml:mtext></mml:msub><mml:mo>+</mml:mo><mml:msub><mml:mi>M</mml:mi><mml:mtext>EC</mml:mtext></mml:msub><mml:mo>)</mml:mo></mml:mrow></mml:math></inline-formula>), where <inline-formula><mml:math id="M135" display="inline"><mml:mrow><mml:msub><mml:mi mathvariant="italic">ρ</mml:mi><mml:mtext>EC</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> and <inline-formula><mml:math id="M136" display="inline"><mml:mrow><mml:msub><mml:mi mathvariant="italic">ρ</mml:mi><mml:mtext>OC</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> are the densities of elemental and organic carbon, respectively, and expressed as

          <disp-formula id="Ch1.E4" content-type="numbered"><label>4</label><mml:math id="M137" display="block"><mml:mrow><mml:msub><mml:mi mathvariant="italic">ρ</mml:mi><mml:mtext>true</mml:mtext></mml:msub><mml:mo>=</mml:mo><mml:mstyle displaystyle="true"><mml:mfrac style="display"><mml:mn mathvariant="normal">1</mml:mn><mml:mrow><mml:mstyle displaystyle="false"><mml:mfrac style="text"><mml:mi>x</mml:mi><mml:mrow><mml:msub><mml:mi mathvariant="italic">ρ</mml:mi><mml:mtext>OC</mml:mtext></mml:msub></mml:mrow></mml:mfrac></mml:mstyle><mml:mo>+</mml:mo><mml:mstyle displaystyle="false"><mml:mfrac style="text"><mml:mrow><mml:mn mathvariant="normal">1</mml:mn><mml:mo>-</mml:mo><mml:mi>x</mml:mi></mml:mrow><mml:mrow><mml:msub><mml:mi mathvariant="italic">ρ</mml:mi><mml:mtext>EC</mml:mtext></mml:msub></mml:mrow></mml:mfrac></mml:mstyle></mml:mrow></mml:mfrac></mml:mstyle><mml:mo>.</mml:mo></mml:mrow></mml:math></disp-formula></p>
      <p id="d2e2501">Based on data from a wide range of liquid, gaseous, or solid fuel combustion soot, Ouf et al. (2019) suggested that a constant true density could be considered with a mean value of <inline-formula><mml:math id="M138" display="inline"><mml:mrow><mml:msub><mml:mi mathvariant="italic">ρ</mml:mi><mml:mtext>EC</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> <inline-formula><mml:math id="M139" display="inline"><mml:mo>=</mml:mo></mml:math></inline-formula> 1834 <inline-formula><mml:math id="M140" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">kg</mml:mi><mml:mspace width="0.125em" linebreak="nobreak"/><mml:msup><mml:mi mathvariant="normal">m</mml:mi><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">3</mml:mn></mml:mrow></mml:msup></mml:mrow></mml:math></inline-formula> for soot with OC contents below 5 %. In the absence of metallic compounds, which is the case for the Mini-CAST soot, they also proposed considering three different ranges of the true density as a function of <inline-formula><mml:math id="M141" display="inline"><mml:mi>x</mml:mi></mml:math></inline-formula>, the organic carbon to total carbon ratio: for low-OC contents (i.e., below 5 %) and high-OC contents (i.e., above 20 %), they consider the constant true density values <inline-formula><mml:math id="M142" display="inline"><mml:mrow><mml:msub><mml:mi mathvariant="italic">ρ</mml:mi><mml:mtext>EC</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> and <inline-formula><mml:math id="M143" display="inline"><mml:mrow><mml:msub><mml:mi mathvariant="italic">ρ</mml:mi><mml:mtext>OC</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula>, respectively. For intermediate-OC-content values between these two reference points, a linear mixing law as a function of <inline-formula><mml:math id="M144" display="inline"><mml:mi>x</mml:mi></mml:math></inline-formula> has been suggested by Ouf et al. (2019). Using this zone-based approach, we observed an underestimation of soot mass for almost all measurement points. Therefore, we considered using the Park mixing model (Eq. 4), with the values <inline-formula><mml:math id="M145" display="inline"><mml:mrow><mml:msub><mml:mi mathvariant="italic">ρ</mml:mi><mml:mtext>EC</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> <inline-formula><mml:math id="M146" display="inline"><mml:mo>=</mml:mo></mml:math></inline-formula> 1834 <inline-formula><mml:math id="M147" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">kg</mml:mi><mml:mspace width="0.125em" linebreak="nobreak"/><mml:msup><mml:mi mathvariant="normal">m</mml:mi><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">3</mml:mn></mml:mrow></mml:msup></mml:mrow></mml:math></inline-formula> for <inline-formula><mml:math id="M148" display="inline"><mml:mrow><mml:mi>x</mml:mi><mml:mo>=</mml:mo><mml:mn mathvariant="normal">0</mml:mn></mml:mrow></mml:math></inline-formula> and <inline-formula><mml:math id="M149" display="inline"><mml:mrow><mml:msub><mml:mi mathvariant="italic">ρ</mml:mi><mml:mtext>OC</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> <inline-formula><mml:math id="M150" display="inline"><mml:mo>=</mml:mo></mml:math></inline-formula> 1285 <inline-formula><mml:math id="M151" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">kg</mml:mi><mml:mspace linebreak="nobreak" width="0.125em"/><mml:msup><mml:mi mathvariant="normal">m</mml:mi><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">3</mml:mn></mml:mrow></mml:msup></mml:mrow></mml:math></inline-formula>, as suggested by Ouf et al. (2019). We report in Table 2 the values obtained for the <inline-formula><mml:math id="M152" display="inline"><mml:mrow class="chem"><mml:mi mathvariant="normal">OC</mml:mi><mml:mo>/</mml:mo><mml:mi mathvariant="normal">TC</mml:mi></mml:mrow></mml:math></inline-formula> ratios as determined by thermal–optical analysis and the corresponding true densities calculated with the Park mixing model (Eq. 4) that were used to evaluate the SMPS true density mass concentrations reported in Fig. 8. The measured values of the <inline-formula><mml:math id="M153" display="inline"><mml:mrow class="chem"><mml:mi mathvariant="normal">OC</mml:mi><mml:mo>/</mml:mo><mml:mi mathvariant="normal">TC</mml:mi></mml:mrow></mml:math></inline-formula> organic fraction contained in soot compare well with those obtained in Marhaba et al. (2019) for equivalent operating conditions of the Mini-CAST.</p>
      <p id="d2e2684">For the considered points named CAST1, CAST2, and CAST3 in Marhaba et al. (2019), they reported <inline-formula><mml:math id="M154" display="inline"><mml:mrow class="chem"><mml:mi mathvariant="normal">OC</mml:mi><mml:mo>/</mml:mo><mml:mi mathvariant="normal">TC</mml:mi></mml:mrow></mml:math></inline-formula> ratio values of 87 %, 46.8 %, and 4.1 %, respectively, with CAST3 corresponding to 1 <inline-formula><mml:math id="M155" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">L</mml:mi><mml:mspace linebreak="nobreak" width="0.125em"/><mml:msup><mml:mi mathvariant="normal">min</mml:mi><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:msup></mml:mrow></mml:math></inline-formula>, CAST2 to 1.15 <inline-formula><mml:math id="M156" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">L</mml:mi><mml:mspace width="0.125em" linebreak="nobreak"/><mml:msup><mml:mi mathvariant="normal">min</mml:mi><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:msup></mml:mrow></mml:math></inline-formula>, and CAST1 to 1.5 <inline-formula><mml:math id="M157" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">L</mml:mi><mml:mspace linebreak="nobreak" width="0.125em"/><mml:msup><mml:mi mathvariant="normal">min</mml:mi><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:msup></mml:mrow></mml:math></inline-formula> of oxidation airflow. In the same operating conditions, we measured corresponding <inline-formula><mml:math id="M158" display="inline"><mml:mrow class="chem"><mml:mi mathvariant="normal">OC</mml:mi><mml:mo>/</mml:mo><mml:mi mathvariant="normal">TC</mml:mi></mml:mrow></mml:math></inline-formula> values of 56.7 %, 46 %, and 6.2 %, respectively. For  CAST3, our measured value is significantly lower, while the two other points are coherent. However, as highlighted by Moore et al. (2014), soot production conditions can vary with parameters other than the overall <inline-formula><mml:math id="M159" display="inline"><mml:mrow class="chem"><mml:mi mathvariant="normal">carbon</mml:mi><mml:mo>/</mml:mo><mml:mi mathvariant="normal">oxygen</mml:mi></mml:mrow></mml:math></inline-formula> ratio of the flame, and variations in mode size or <inline-formula><mml:math id="M160" display="inline"><mml:mrow class="chem"><mml:mi mathvariant="normal">OC</mml:mi><mml:mo>/</mml:mo><mml:mi mathvariant="normal">TC</mml:mi></mml:mrow></mml:math></inline-formula> ratio have already been observed between different studies using different Cast or Mini-CAST generators. This makes it difficult to directly compare <inline-formula><mml:math id="M161" display="inline"><mml:mrow class="chem"><mml:mi mathvariant="normal">OC</mml:mi><mml:mo>/</mml:mo><mml:mi mathvariant="normal">TC</mml:mi></mml:mrow></mml:math></inline-formula> data between studies conducted with this type of generator and justifies the necessity of carrying out  thermal–optical analysis of the organic content of soot.</p>
      <p id="d2e2799">As can be observed in Fig. 8 (right), for the mass concentrations determined from SMPS size distributions and the true density, as well as for the evaluations based on the corrected PPS, we observe good agreement with the mass concentration obtained from the TEOM; except for a very limited number of points and at very low mass concentration measurements, both mass concentrations evaluated from the “SMPS, true density” and the PPS after correction fall within a 10 % interval of the TEOM reference mass concentration.</p>
      <p id="d2e2802">Furthermore, other approaches have been developed to estimate an “effective density” of soot particles, considering their fractal nature. These methods are based on so-called tandem techniques (Ghazi et al., 2013; Maricq and Xu, 2004; Tavakoli and Olfert, 2014) for evaluating this effective density. Based on an analysis of various data sets available in the literature, Olfert and Rogak (2019) proposed a model that expresses the effective density as a function of the mobility diameter:

          <disp-formula id="Ch1.E5" content-type="numbered"><label>5</label><mml:math id="M162" display="block"><mml:mrow><mml:msub><mml:mi mathvariant="italic">ρ</mml:mi><mml:mtext>eff</mml:mtext></mml:msub><mml:mo>=</mml:mo><mml:msub><mml:mi mathvariant="italic">ρ</mml:mi><mml:mrow><mml:mtext>eff</mml:mtext><mml:mo>,</mml:mo><mml:mn mathvariant="normal">100</mml:mn></mml:mrow></mml:msub><mml:msup><mml:mfenced close=")" open="("><mml:mstyle displaystyle="true"><mml:mfrac style="display"><mml:mrow><mml:msub><mml:mi>d</mml:mi><mml:mi mathvariant="normal">m</mml:mi></mml:msub></mml:mrow><mml:mn mathvariant="normal">100</mml:mn></mml:mfrac></mml:mstyle></mml:mfenced><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">0.52</mml:mn></mml:mrow></mml:msup><mml:mtext> and  with </mml:mtext><mml:mi>m</mml:mi><mml:mo>=</mml:mo><mml:msub><mml:mi mathvariant="italic">ρ</mml:mi><mml:mtext>eff</mml:mtext></mml:msub><mml:mo>⋅</mml:mo><mml:mi mathvariant="italic">π</mml:mi><mml:msubsup><mml:mi>d</mml:mi><mml:mi mathvariant="normal">m</mml:mi><mml:mn mathvariant="normal">3</mml:mn></mml:msubsup><mml:mo>/</mml:mo><mml:mn mathvariant="normal">6</mml:mn><mml:mo>,</mml:mo></mml:mrow></mml:math></disp-formula>

        with <inline-formula><mml:math id="M163" display="inline"><mml:mrow><mml:msub><mml:mi>d</mml:mi><mml:mi mathvariant="normal">m</mml:mi></mml:msub></mml:mrow></mml:math></inline-formula> being the aggregate mobility diameter, <inline-formula><mml:math id="M164" display="inline"><mml:mi>m</mml:mi></mml:math></inline-formula> its mass, and <inline-formula><mml:math id="M165" display="inline"><mml:mrow><mml:msub><mml:mi mathvariant="italic">ρ</mml:mi><mml:mrow><mml:mtext>eff</mml:mtext><mml:mo>,</mml:mo><mml:mn mathvariant="normal">100</mml:mn></mml:mrow></mml:msub></mml:mrow></mml:math></inline-formula> the effective density for aggregates with a 100 <inline-formula><mml:math id="M166" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">nm</mml:mi></mml:mrow></mml:math></inline-formula> reference scale. This model allows the evaluation of the decrease in effective density with the mobility diameter <inline-formula><mml:math id="M167" display="inline"><mml:mrow><mml:msub><mml:mi>d</mml:mi><mml:mi mathvariant="normal">m</mml:mi></mml:msub></mml:mrow></mml:math></inline-formula> of soot aggregates. The data used to develop this model originate primarily from studies of particles produced by internal combustion engines or gas turbines, and a value of 510 <inline-formula><mml:math id="M168" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">kg</mml:mi><mml:mspace linebreak="nobreak" width="0.125em"/><mml:msup><mml:mi mathvariant="normal">m</mml:mi><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">3</mml:mn></mml:mrow></mml:msup></mml:mrow></mml:math></inline-formula> for the effective density at 100 <inline-formula><mml:math id="M169" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">nm</mml:mi></mml:mrow></mml:math></inline-formula> was proposed by Olfert and Rogak (2019). However, Yon et al. (2015) reported higher effective density values at 100 <inline-formula><mml:math id="M170" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">nm</mml:mi></mml:mrow></mml:math></inline-formula> for the Mini-CAST, with values ranging from 1100 to 765 <inline-formula><mml:math id="M171" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">kg</mml:mi><mml:mspace linebreak="nobreak" width="0.125em"/><mml:msup><mml:mi mathvariant="normal">m</mml:mi><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">3</mml:mn></mml:mrow></mml:msup></mml:mrow></mml:math></inline-formula> for oxidation airflow rates between 1 and 1.5 <inline-formula><mml:math id="M172" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">L</mml:mi><mml:mspace width="0.125em" linebreak="nobreak"/><mml:msup><mml:mi mathvariant="normal">min</mml:mi><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:msup></mml:mrow></mml:math></inline-formula>. Although only three operating points were investigated, the decrease in effective density with increasing oxidation airflow rate was found to be linear. Additionally, we observed that the decay in <inline-formula><mml:math id="M173" display="inline"><mml:mrow class="chem"><mml:mi mathvariant="normal">OC</mml:mi><mml:mo>/</mml:mo><mml:mi mathvariant="normal">TC</mml:mi></mml:mrow></mml:math></inline-formula> with oxidation airflow rate is also linear. We therefore conducted a “best-fit” identification procedure to obtain the values of <inline-formula><mml:math id="M174" display="inline"><mml:mrow><mml:msub><mml:mi mathvariant="italic">ρ</mml:mi><mml:mrow><mml:mtext>eff</mml:mtext><mml:mo>,</mml:mo><mml:mn mathvariant="normal">100</mml:mn></mml:mrow></mml:msub></mml:mrow></mml:math></inline-formula>, the density at 100 <inline-formula><mml:math id="M175" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">nm</mml:mi></mml:mrow></mml:math></inline-formula> that would allow us to recover the TEOM reference mass concentrations from the SMPS analysis together with the Olfert and Rogak (2019) model. We obtained a set of values <inline-formula><mml:math id="M176" display="inline"><mml:mrow><mml:msub><mml:mi mathvariant="italic">ρ</mml:mi><mml:mrow><mml:mtext>eff</mml:mtext><mml:mo>,</mml:mo><mml:mn mathvariant="normal">100</mml:mn></mml:mrow></mml:msub></mml:mrow></mml:math></inline-formula> from the best-fit analysis (see Fig. 7) and observed that the change in this density at 100 <inline-formula><mml:math id="M177" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">nm</mml:mi></mml:mrow></mml:math></inline-formula> with the <inline-formula><mml:math id="M178" display="inline"><mml:mrow class="chem"><mml:mi mathvariant="normal">OC</mml:mi><mml:mo>/</mml:mo><mml:mi mathvariant="normal">TC</mml:mi></mml:mrow></mml:math></inline-formula> ratio can be represented by a linear interpolation, expressed as

          <disp-formula id="Ch1.E6" content-type="numbered"><label>6</label><mml:math id="M179" display="block"><mml:mrow><mml:msub><mml:mi mathvariant="italic">ρ</mml:mi><mml:mrow><mml:mtext>eff</mml:mtext><mml:mo>,</mml:mo><mml:mn mathvariant="normal">100</mml:mn></mml:mrow></mml:msub><mml:mo>(</mml:mo><mml:mi>x</mml:mi><mml:mo>)</mml:mo><mml:mo>=</mml:mo><mml:mn mathvariant="normal">932</mml:mn><mml:mo>+</mml:mo><mml:mn mathvariant="normal">661</mml:mn><mml:mo>⋅</mml:mo><mml:mi>x</mml:mi><mml:mo>,</mml:mo></mml:mrow></mml:math></disp-formula>

        with <inline-formula><mml:math id="M180" display="inline"><mml:mi>x</mml:mi></mml:math></inline-formula> being the <inline-formula><mml:math id="M181" display="inline"><mml:mrow class="chem"><mml:mi mathvariant="normal">OC</mml:mi><mml:mo>/</mml:mo><mml:mi mathvariant="normal">TC</mml:mi></mml:mrow></mml:math></inline-formula> ratio.</p>

      <fig id="F7"><label>Figure 7</label><caption><p id="d2e3126">Identification of <inline-formula><mml:math id="M182" display="inline"><mml:mrow><mml:msub><mml:mi mathvariant="italic">ρ</mml:mi><mml:mrow><mml:mtext>eff</mml:mtext><mml:mo>,</mml:mo><mml:mn mathvariant="normal">100</mml:mn></mml:mrow></mml:msub></mml:mrow></mml:math></inline-formula> as a function of the <inline-formula><mml:math id="M183" display="inline"><mml:mrow class="chem"><mml:mi mathvariant="normal">OC</mml:mi><mml:mo>/</mml:mo><mml:mi mathvariant="normal">TC</mml:mi></mml:mrow></mml:math></inline-formula> ratio.</p></caption>
        <graphic xlink:href="https://ar.copernicus.org/articles/4/121/2026/ar-4-121-2026-f07.png"/>

      </fig>

      <fig id="F8" specific-use="star"><label>Figure 8</label><caption><p id="d2e3165">Mass concentration evaluations as a function of the median diameter (left) and comparison of PPS and SMPS mass concentration evaluations with TEOM measurements (right).</p></caption>
        <graphic xlink:href="https://ar.copernicus.org/articles/4/121/2026/ar-4-121-2026-f08.png"/>

      </fig>

      <p id="d2e3175">From  Eq. (5), interpolated values of <inline-formula><mml:math id="M184" display="inline"><mml:mrow><mml:msub><mml:mi mathvariant="italic">ρ</mml:mi><mml:mrow><mml:mtext>eff</mml:mtext><mml:mo>,</mml:mo><mml:mn mathvariant="normal">100</mml:mn></mml:mrow></mml:msub></mml:mrow></mml:math></inline-formula> can be evaluated. These effective densities at 100 <inline-formula><mml:math id="M185" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">nm</mml:mi></mml:mrow></mml:math></inline-formula> determined through this procedure are reported in Table 2, and the corresponding mass concentrations, labeled “SMPS effective density”, are shown in Fig. 8: the use of this effective density model combined with the measured size distributions results in a good estimation of the mass concentration.</p>
      <p id="d2e3202">Figure 9 shows the mass concentrations measured by the MA300 for ultraviolet and infrared wavelengths as a function of those measured by the TEOM reference method for soot produced with the different oxidation airflow rates tested (value indicated next to each measuring point, in <inline-formula><mml:math id="M186" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">L</mml:mi><mml:mspace linebreak="nobreak" width="0.125em"/><mml:msup><mml:mi mathvariant="normal">min</mml:mi><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:msup></mml:mrow></mml:math></inline-formula>). For oxidation air of 0.9 <inline-formula><mml:math id="M187" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">L</mml:mi><mml:mspace linebreak="nobreak" width="0.125em"/><mml:msup><mml:mi mathvariant="normal">min</mml:mi><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:msup></mml:mrow></mml:math></inline-formula>, the generated soot is composed of  68 % organic carbon. This percentage drops to around 6 % for that generated with 1.5 <inline-formula><mml:math id="M188" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">L</mml:mi><mml:mspace width="0.125em" linebreak="nobreak"/><mml:msup><mml:mi mathvariant="normal">min</mml:mi><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:msup></mml:mrow></mml:math></inline-formula> oxidation air.</p>

      <fig id="F9"><label>Figure 9</label><caption><p id="d2e3258">Mass concentrations measured by the MA300 as a function of the TEOM reference measurements.</p></caption>
        <graphic xlink:href="https://ar.copernicus.org/articles/4/121/2026/ar-4-121-2026-f09.png"/>

      </fig>

      <p id="d2e3267">The equivalent black carbon (eBC) mass concentration evaluated by the MA300 with Eq. (1) is based on a constant value of the mass absorption coefficient <inline-formula><mml:math id="M189" display="inline"><mml:mrow><mml:msub><mml:mi mathvariant="italic">σ</mml:mi><mml:mtext>MAC</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> correction. We observe  good linearity of the measured mass concentration in the UV range for an oxidation airflow rate below 1.25 <inline-formula><mml:math id="M190" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">L</mml:mi><mml:mspace width="0.125em" linebreak="nobreak"/><mml:msup><mml:mi mathvariant="normal">min</mml:mi><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:msup></mml:mrow></mml:math></inline-formula>, thus corresponding to <inline-formula><mml:math id="M191" display="inline"><mml:mrow class="chem"><mml:mi mathvariant="normal">OC</mml:mi><mml:mo>/</mml:mo><mml:mi mathvariant="normal">TC</mml:mi></mml:mrow></mml:math></inline-formula> ratios above 38 %. In the same way, the IR mass concentration determination is linear for an oxidation airflow rate above 1.3 <inline-formula><mml:math id="M192" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">L</mml:mi><mml:mspace width="0.125em" linebreak="nobreak"/><mml:msup><mml:mi mathvariant="normal">min</mml:mi><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:msup></mml:mrow></mml:math></inline-formula>, corresponding to <inline-formula><mml:math id="M193" display="inline"><mml:mrow class="chem"><mml:mi mathvariant="normal">OC</mml:mi><mml:mo>/</mml:mo><mml:mi mathvariant="normal">TC</mml:mi></mml:mrow></mml:math></inline-formula> ratios below 24.3 %, which are soot particles predominantly made up of elemental carbon. In both UV and IR cases, the deviation from linearity may be a consequence of changes in the MAC value and the multiple-scattering parameter.</p>
</sec>
<sec id="Ch1.S4" sec-type="conclusions">
  <label>4</label><title>Conclusions</title>
      <p id="d2e3347">For this intercomparison of instruments and measurement techniques for the evaluation of  soot mass concentration, we used a Mini-CAST generator commonly employed in laboratory experiments to produce soot particles under stable and controlled conditions. This generator allows us to generate soot that is representative of that emitted by internal combustion engines,  in fire situations, or during biomass combustion. By significantly and continuously varying one of the Mini-CAST parameters, we were able to generate a set of eight soot particle measurement points, with significant variations in their organic to total carbon ratio (<inline-formula><mml:math id="M194" display="inline"><mml:mrow class="chem"><mml:mi mathvariant="normal">OC</mml:mi><mml:mo>/</mml:mo><mml:mi mathvariant="normal">TC</mml:mi></mml:mrow></mml:math></inline-formula>), ranging from 6 % to 68 %, and in their size distributions, while also achieving mass concentrations covering values from 7 to 96 <inline-formula><mml:math id="M195" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">mg</mml:mi><mml:mspace width="0.125em" linebreak="nobreak"/><mml:msup><mml:mi mathvariant="normal">m</mml:mi><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">3</mml:mn></mml:mrow></mml:msup></mml:mrow></mml:math></inline-formula>. Over a mass concentration range spanning almost 2 decades, we obtained a very good correlation between the gravimetric method using filter sampling, the real-time online methods with the reference TEOM instrument, and the offline thermal–optical analysis, which also provided access to the <inline-formula><mml:math id="M196" display="inline"><mml:mrow class="chem"><mml:mi mathvariant="normal">OC</mml:mi><mml:mo>/</mml:mo><mml:mi mathvariant="normal">TC</mml:mi></mml:mrow></mml:math></inline-formula> fraction. Based on the electrical charging of the aerosol particles, the Pegasor particle sensor (PPS) analyzer provides  real-time measurement of the mass concentration at 1 Hz frequency but with a response that depends on the particle size distribution. We established that with an appropriate correction based on the aerosol active surface, the PPS can also provide relevant quantitative information on the soot mass concentration. Finally, the MA300 Aethalometer was evaluated over a wide range of <inline-formula><mml:math id="M197" display="inline"><mml:mrow class="chem"><mml:mi mathvariant="normal">OC</mml:mi><mml:mo>/</mml:mo><mml:mi mathvariant="normal">TC</mml:mi></mml:mrow></mml:math></inline-formula> ratios. In this instrument, the measurement technique is based on the attenuation of a light beam with different wavelengths through a particle cake accumulating on a filter. This attenuation is dependent on the wavelength and the <inline-formula><mml:math id="M198" display="inline"><mml:mrow class="chem"><mml:mi mathvariant="normal">OC</mml:mi><mml:mo>/</mml:mo><mml:mi mathvariant="normal">TC</mml:mi></mml:mrow></mml:math></inline-formula> ratio. We were able to determine a limit in soot organic content, with a maximum value of <inline-formula><mml:math id="M199" display="inline"><mml:mrow class="chem"><mml:mi mathvariant="normal">OC</mml:mi><mml:mo>/</mml:mo><mml:mi mathvariant="normal">TC</mml:mi></mml:mrow></mml:math></inline-formula> <inline-formula><mml:math id="M200" display="inline"><mml:mo>=</mml:mo></mml:math></inline-formula> 24 % for which the infrared measurement allows quantification of the total mass concentration, rather than only the so-called black carbon fraction. We also established that the ultraviolet wavelength, usually used to quantify brown carbon, can also provide an evaluation of the total mass concentration when the organic carbon ratios are sufficiently high (at least higher than 38 %). For the analysis of soot mass concentration based on SMPS size distribution measurements, we applied two methods: one based on a “true density” constant for each operating point of the Mini-CAST and a second one that accounts for the effective density of the aggregates, considering both their mobility diameter and the <inline-formula><mml:math id="M201" display="inline"><mml:mrow class="chem"><mml:mi mathvariant="normal">OC</mml:mi><mml:mo>/</mml:mo><mml:mi mathvariant="normal">TC</mml:mi></mml:mrow></mml:math></inline-formula> ratio. Originally, in the considered model of Olfert and Rogak (2019), the effective density of aggregates is calculated based on their mobility diameter and a constant reference effective density at 100 <inline-formula><mml:math id="M202" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">nm</mml:mi></mml:mrow></mml:math></inline-formula>. In this work, we propose considering that this reference effective density is a function of the <inline-formula><mml:math id="M203" display="inline"><mml:mrow class="chem"><mml:mi mathvariant="normal">OC</mml:mi><mml:mo>/</mml:mo><mml:mi mathvariant="normal">TC</mml:mi></mml:mrow></mml:math></inline-formula> ratio. This approach – considering both the <inline-formula><mml:math id="M204" display="inline"><mml:mrow class="chem"><mml:mi mathvariant="normal">OC</mml:mi><mml:mo>/</mml:mo><mml:mi mathvariant="normal">TC</mml:mi></mml:mrow></mml:math></inline-formula> ratio and the mobility diameter – results in mass concentrations that are in good agreement with the reference TEOM measurements. The results of this study show that the selected operating points led to simultaneous variations in mass concentration, size distribution, and the <inline-formula><mml:math id="M205" display="inline"><mml:mrow class="chem"><mml:mi mathvariant="normal">OC</mml:mi><mml:mo>/</mml:mo><mml:mi mathvariant="normal">TC</mml:mi></mml:mrow></mml:math></inline-formula> ratio. It would be relevant, by varying other gas flow rates of the Mini-CAST or aerosol dilution conditions, to better decouple the parameters under investigation in future studies.</p>
</sec>

      
      </body>
    <back><notes notes-type="dataavailability"><title>Data availability</title>

      <p id="d2e3497">The raw data can be provided upon request to the authors.</p>
  </notes><notes notes-type="authorcontribution"><title>Author contributions</title>

      <p id="d2e3503">BS and AK planned the measurement campaign; BS, AK, and GP performed the measurements; BS, AK, and GP analyzed the data; BS and AK wrote the manuscript draft; and BS and AK reviewed and edited the paper.</p>
  </notes><notes notes-type="competinginterests"><title>Competing interests</title>

      <p id="d2e3509">The contact author has declared that none of the authors has any competing interests.</p>
  </notes><notes notes-type="disclaimer"><title>Disclaimer</title>

      <p id="d2e3515">Publisher's note: Copernicus Publications remains neutral with regard to jurisdictional claims made in the text, published maps, institutional affiliations, or any other geographical representation in this paper. The authors bear the ultimate responsibility for providing appropriate place names. Views expressed in the text are those of the authors and do not necessarily reflect the views of the publisher.</p>
  </notes><ack><title>Acknowledgements</title><p id="d2e3521">The authors thank the reviewers for their contributions, which improved this paper. They also thank François Gensdarmes for constructive discussions.</p></ack><notes notes-type="reviewstatement"><title>Review statement</title>

      <p id="d2e3526">This paper was edited by Attila Nagy and reviewed by three anonymous referees.</p>
  </notes><ref-list>
    <title>References</title>

      <ref id="bib1.bib1"><label>1</label><mixed-citation>Aakko-Saksa, P., Kuittinen, N., Murtonen, T., Koponen, P., Aurela, M., Järvinen, A., Teinilä, K., Saarikoski, S., Barreira, L. M. F., Salo, L., Karjalainen, P., Ortega, I. K., Delhaye, D., Lehtoranta, K., Vesala, H., Jalava, P., Rönkkö, T., and Timonen, H.: Suitability of different methods for measuring black carbon emissions from marine engines, Atmosphere (Basel), 13, <ext-link xlink:href="https://doi.org/10.3390/atmos13010031" ext-link-type="DOI">10.3390/atmos13010031</ext-link>, 2022.</mixed-citation></ref>
      <ref id="bib1.bib2"><label>2</label><mixed-citation>Allen, G., Sioutas, C., Koutrakis, P., Reiss, R., Lurmann, F. W., and Roberts, P. T.: Evaluation of the TEOM<sup>®</sup> Method for Measurement of Ambient Particulate Mass in Urban Areas, J. Air Waste Manage. Assoc., 47, 682–689, <ext-link xlink:href="https://doi.org/10.1080/10473289.1997.10463923" ext-link-type="DOI">10.1080/10473289.1997.10463923</ext-link>, 1997.</mixed-citation></ref>
      <ref id="bib1.bib3"><label>3</label><mixed-citation>Arnott, W. P., Hamasha, K., Moosmüller, H., Sheridan, P. J., and Ogren, J. A.: Towards Aerosol Light-Absorption Measurements with a 7-Wavelength Aethalometer: Evaluation with a Photoacoustic Instrument and 3-Wavelength Nephelometer, Aerosol Sci. Tech., 39, 17–29, <ext-link xlink:href="https://doi.org/10.1080/027868290901972" ext-link-type="DOI">10.1080/027868290901972</ext-link>, 2005.</mixed-citation></ref>
      <ref id="bib1.bib4"><label>4</label><mixed-citation>Bescond, A., Yon, J., Ouf, F. X., Rozé, C., Coppalle, A., Parent, P., Ferry, D., and Laffon, C.: Soot optical properties determined by analyzing extinction spectra in the visible near-UV: Toward an optical speciation according to constituents and structure, J. Aerosol Sci., 101, 118–132, <ext-link xlink:href="https://doi.org/10.1016/j.jaerosci.2016.08.001" ext-link-type="DOI">10.1016/j.jaerosci.2016.08.001</ext-link>, 2016.</mixed-citation></ref>
      <ref id="bib1.bib5"><label>5</label><mixed-citation>Blanco-Donado, E. P., Schneider, I. L., Artaxo, P., Lozano-Osorio, J., Portz, L., and Oliveira, M. L. S.: Source identification and global implications of black carbon, Geoscience Frontiers, 13, 101149, <ext-link xlink:href="https://doi.org/10.1016/J.GSF.2021.101149" ext-link-type="DOI">10.1016/J.GSF.2021.101149</ext-link>, 2022.</mixed-citation></ref>
      <ref id="bib1.bib6"><label>6</label><mixed-citation>Chakraborty, M., Giang, A., and Zimmerman, N.: Performance evaluation of portable dual-spot micro-aethalometers for source identification of black carbon aerosols: application to wildfire smoke and traffic emissions in the Pacific Northwest, Atmos. Meas. Tech., 16, 2333–2352, <ext-link xlink:href="https://doi.org/10.5194/amt-16-2333-2023" ext-link-type="DOI">10.5194/amt-16-2333-2023</ext-link>, 2023.</mixed-citation></ref>
      <ref id="bib1.bib7"><label>7</label><mixed-citation>Chow, J. C., Watson, J. G., Crow, D., Lowenthal, D. H., and Merrifield, T.: Comparison of IMPROVE and NIOSH Carbon Measurements, Aerosol Science and Technology, 34, 23–34, <ext-link xlink:href="https://doi.org/10.1080/02786820119073" ext-link-type="DOI">10.1080/02786820119073</ext-link>, 2001.</mixed-citation></ref>
      <ref id="bib1.bib8"><label>8</label><mixed-citation>Collaud Coen, M., Weingartner, E., Apituley, A., Ceburnis, D., Fierz-Schmidhauser, R., Flentje, H., Henzing, J. S., Jennings, S. G., Moerman, M., Petzold, A., Schmid, O., and Baltensperger, U.: Minimizing light absorption measurement artifacts of the Aethalometer: evaluation of five correction algorithms, Atmos. Meas. Tech., 3, 457–474, <ext-link xlink:href="https://doi.org/10.5194/amt-3-457-2010" ext-link-type="DOI">10.5194/amt-3-457-2010</ext-link>, 2010.</mixed-citation></ref>
      <ref id="bib1.bib9"><label>9</label><mixed-citation>Drinovec, L., Močnik, G., Zotter, P., Prévôt, A. S. H., Ruckstuhl, C., Coz, E., Rupakheti, M., Sciare, J., Müller, T., Wiedensohler, A., and Hansen, A. D. A.: The “dual-spot” Aethalometer: an improved measurement of aerosol black carbon with real-time loading compensation, Atmos. Meas. Tech., 8, 1965–1979, <ext-link xlink:href="https://doi.org/10.5194/amt-8-1965-2015" ext-link-type="DOI">10.5194/amt-8-1965-2015</ext-link>, 2015.</mixed-citation></ref>
      <ref id="bib1.bib10"><label>10</label><mixed-citation>Elomaa, J. T., Luoma, K., Harni, S. D., Virkkula, A., Timonen, H., and Petäjä, T.: The applicability and challenges of black carbon sensors in monitoring networks, Aerosol Research, 3, 293–314, <ext-link xlink:href="https://doi.org/10.5194/ar-3-293-2025" ext-link-type="DOI">10.5194/ar-3-293-2025</ext-link>, 2025.</mixed-citation></ref>
      <ref id="bib1.bib11"><label>11</label><mixed-citation>Favez, O., Cachier, H., Sciare, J., and Le Moullec, Y.: Characterization and contribution to <inline-formula><mml:math id="M206" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">PM</mml:mi><mml:mn mathvariant="normal">2.5</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> of semi-volatile aerosols in Paris (France), Atmos. Environ., 41, 7969–7976, <ext-link xlink:href="https://doi.org/10.1016/j.atmosenv.2007.09.031" ext-link-type="DOI">10.1016/j.atmosenv.2007.09.031</ext-link>, 2007.</mixed-citation></ref>
      <ref id="bib1.bib12"><label>12</label><mixed-citation>Ghazi, R., Tjong, H., Soewono, A., Rogak, S. N., and Olfert, J. S.: Mass, mobility, volatility, and morphology of soot particles generated by a mckenna and inverted burner, Aerosol Science and Technology, 47, 395–405, <ext-link xlink:href="https://doi.org/10.1080/02786826.2012.755259" ext-link-type="DOI">10.1080/02786826.2012.755259</ext-link>, 2013.</mixed-citation></ref>
      <ref id="bib1.bib13"><label>13</label><mixed-citation>Gren, L., Krais, A. M., Assarsson, E., Broberg, K., Engfeldt, M., Lindh, C., Strandberg, B., Pagels, J., and Hedmer, M.: Underground emissions and miners' personal exposure to diesel and renewable diesel exhaust in a Swedish iron ore mine, Int. Arch. Occup. Environ. Health, 95, 1369–1388, <ext-link xlink:href="https://doi.org/10.1007/s00420-022-01843-x" ext-link-type="DOI">10.1007/s00420-022-01843-x</ext-link>, 2022.</mixed-citation></ref>
      <ref id="bib1.bib14"><label>14</label><mixed-citation>Gundel, L. A., Dod, R. L., Rosen, H., and Novakov, T.: The relationship between optical attenuation and black carbon concentration for ambient and source particles, Science of The Total Environment, 36, 197–202, <ext-link xlink:href="https://doi.org/10.1016/0048-9697(84)90266-3" ext-link-type="DOI">10.1016/0048-9697(84)90266-3</ext-link>, 1984.</mixed-citation></ref>
      <ref id="bib1.bib15"><label>15</label><mixed-citation>Hansen, A. D. A., Rosen, H., and Novakov, T.: The aethalometer — An instrument for the real-time measurement of optical absorption by aerosol particles, Science of The Total Environment, 36, 191–196, <ext-link xlink:href="https://doi.org/10.1016/0048-9697(84)90265-1" ext-link-type="DOI">10.1016/0048-9697(84)90265-1</ext-link>, 1984.</mixed-citation></ref>
      <ref id="bib1.bib16"><label>16</label><mixed-citation>Jung, H. and Kittelson, D. B.: Characterization of aerosol surface instruments in transition regime, Aerosol Science and Technology, 39, 902–911, <ext-link xlink:href="https://doi.org/10.1080/02786820500295701" ext-link-type="DOI">10.1080/02786820500295701</ext-link>, 2005.</mixed-citation></ref>
      <ref id="bib1.bib17"><label>17</label><mixed-citation>Kort, A., Ouf, F. X., Gelain, T., Malet, J., Lakhmi, R., Breuil, P., and Viricelle, J. P.: Quantification of soot deposit on a resistive sensor: Proposal of an experimental calibration protocol, J. Aerosol Sci., 156, <ext-link xlink:href="https://doi.org/10.1016/j.jaerosci.2021.105783" ext-link-type="DOI">10.1016/j.jaerosci.2021.105783</ext-link>, 2021.</mixed-citation></ref>
      <ref id="bib1.bib18"><label>18</label><mixed-citation>Kort, A., Ouf, F. X., Lakhmi, R., Gelain, T., Malet, J., Breuil, P., and Viricelle, J. P.: An Innovative Method for Soot Deposit Quantification Using a CO2 Sensor: Application to Fire Studies in Research Facilities, J. Aerosol Sci., 164, <ext-link xlink:href="https://doi.org/10.1016/j.jaerosci.2022.106005" ext-link-type="DOI">10.1016/j.jaerosci.2022.106005</ext-link>, 2022.</mixed-citation></ref>
      <ref id="bib1.bib19"><label>19</label><mixed-citation>Marhaba, I., Ferry, D., Laffon, C., Regier, T. Z., Ouf, F. X., and Parent, P.: Aircraft and MiniCAST soot at the nanoscale, Combust. Flame, 204, 278–289, <ext-link xlink:href="https://doi.org/10.1016/j.combustflame.2019.03.018" ext-link-type="DOI">10.1016/j.combustflame.2019.03.018</ext-link>, 2019.</mixed-citation></ref>
      <ref id="bib1.bib20"><label>20</label><mixed-citation>Maricq, M. M.: Monitoring Motor vehicle pm emissions: An evaluation of three portable low-cost aerosol instruments, Aerosol Science and Technology, 47, 564–573, <ext-link xlink:href="https://doi.org/10.1080/02786826.2013.773394" ext-link-type="DOI">10.1080/02786826.2013.773394</ext-link>, 2013.</mixed-citation></ref>
      <ref id="bib1.bib21"><label>21</label><mixed-citation>Maricq, M. M. and Xu, N.: The effective density and fractal dimension of soot particles from premixed flames and motor vehicle exhaust, J. Aerosol Sci., 35, 1251–1274, <ext-link xlink:href="https://doi.org/10.1016/j.jaerosci.2004.05.002" ext-link-type="DOI">10.1016/j.jaerosci.2004.05.002</ext-link>, 2004.</mixed-citation></ref>
      <ref id="bib1.bib22"><label>22</label><mixed-citation>Mendoza, D. L., Hill, L. D., Blair, J., and Crosman, E. T.: A Long-Term Comparison between the AethLabs MA350 and Aerosol Magee Scientific AE33 Black Carbon Monitors in the Greater Salt Lake City Metropolitan Area, Sensors, 24, <ext-link xlink:href="https://doi.org/10.3390/s24030965" ext-link-type="DOI">10.3390/s24030965</ext-link>, 2024.</mixed-citation></ref>
      <ref id="bib1.bib23"><label>23</label><mixed-citation>Moore, R. H., Ziemba, L. D., Dutcher, D., Beyersdorf, A. J., Chan, K., Crumeyrolle, S., Raymond, T. M., Thornhill, K. L., Winstead, E. L., and Anderson, B. E.: Mapping the operation of the miniature combustion aerosol standard (Mini-CAST) soot generator, Aerosol Science and Technology, 48, 467–479, <ext-link xlink:href="https://doi.org/10.1080/02786826.2014.890694" ext-link-type="DOI">10.1080/02786826.2014.890694</ext-link>, 2014.</mixed-citation></ref>
      <ref id="bib1.bib24"><label>24</label><mixed-citation>Ntziachristos, L., Giechaskiel, B., Ristimäki, J., and Keskinen, J.: Use of a corona charger for the characterisation of automotive exhaust aerosol, J. Aerosol Sci., 35, 943–963, <ext-link xlink:href="https://doi.org/10.1016/j.jaerosci.2004.02.005" ext-link-type="DOI">10.1016/j.jaerosci.2004.02.005</ext-link>, 2004.</mixed-citation></ref>
      <ref id="bib1.bib25"><label>25</label><mixed-citation>Ntziachristos, L., Amanatidis, S., Samaras, Z., Janka, K., and Tikkanen, J.: Application of the Pegasor Particle Sensor for the Measurement of Mass and Particle Number Emissions, SAE Int. J. Fuels Lubr., 6, 521–531, <ext-link xlink:href="https://doi.org/10.4271/2013-01-1561" ext-link-type="DOI">10.4271/2013-01-1561</ext-link>, 2013.</mixed-citation></ref>
      <ref id="bib1.bib26"><label>26</label><mixed-citation>Olfert, J. and Rogak, S.: Universal relations between soot effective density and primary particle size for common combustion sources, Aerosol Sci. Tech., 53, 485–492, <ext-link xlink:href="https://doi.org/10.1080/02786826.2019.1577949" ext-link-type="DOI">10.1080/02786826.2019.1577949</ext-link>, 2019.</mixed-citation></ref>
      <ref id="bib1.bib27"><label>27</label><mixed-citation>Ouf, F. X., Parent, P., Laffon, C., Marhaba, I., Ferry, D., Marcillaud, B., Antonsson, E., Benkoula, S., Liu, X. J., Nicolas, C., Robert, E., Patanen, M., Barreda, F. A., Sublemontier, O., Coppalle, A., Yon, J., Miserque, F., Mostefaoui, T., Regier, T. Z., Mitchell, J. B. A., and Miron, C.: First in-flight synchrotron X-ray absorption and photoemission study of carbon soot nanoparticles, Sci. Rep., 6, <ext-link xlink:href="https://doi.org/10.1038/srep36495" ext-link-type="DOI">10.1038/srep36495</ext-link>, 2016. </mixed-citation></ref>
      <ref id="bib1.bib28"><label>28</label><mixed-citation>Ouf, F. X., Bourrous, S., Fauvel, S., Kort, A., Lintis, L., Nuvoli, J., and Yon, J.: True density of combustion emitted particles: A comparison of results highlighting the influence of the organic contents, J. Aerosol Sci., 134, 1–13, <ext-link xlink:href="https://doi.org/10.1016/j.jaerosci.2019.04.007" ext-link-type="DOI">10.1016/j.jaerosci.2019.04.007</ext-link>, 2019.</mixed-citation></ref>
      <ref id="bib1.bib29"><label>29</label><mixed-citation>Pandis, S. N., Baltensperger, U., Wolfenbarger, J. K., and Seinfeld, J. H.: Inversion of aerosol data from the epiphaniometer, J. Aerosol Sci., 22, 417–428, <ext-link xlink:href="https://doi.org/10.1016/0021-8502(91)90002-Y" ext-link-type="DOI">10.1016/0021-8502(91)90002-Y</ext-link>, 1991.</mixed-citation></ref>
      <ref id="bib1.bib30"><label>30</label><mixed-citation>Park, K., Kittelson, D. B., and McMurry, P. H.: Structural properties of diesel exhaust particles measured by Transmission Electron Microscopy (TEM): Relationships to particle mass and mobility, Aerosol Science and Technology, 38, 881–889, <ext-link xlink:href="https://doi.org/10.1080/027868290505189" ext-link-type="DOI">10.1080/027868290505189</ext-link>, 2004.</mixed-citation></ref>
      <ref id="bib1.bib31"><label>31</label><mixed-citation>Rostedt, A., Arffman, A., Janka, K., Yli-Ojanperä, J., and Keskinen, J.: Characterization and response model of the PPS-M aerosol sensor, Aerosol Science and Technology, 48, 1022–1030, <ext-link xlink:href="https://doi.org/10.1080/02786826.2014.951023" ext-link-type="DOI">10.1080/02786826.2014.951023</ext-link>, 2014.</mixed-citation></ref>
      <ref id="bib1.bib32"><label>32</label><mixed-citation>Sipkens, T. A., Corbin, J. C., Chen, K., Rivellini, L.-H., Abbatt, J., and Olfert, J. S.: Quantitative uncertainty and post-processing for micro-aethalometers measuring black carbon, EGUsphere [preprint], <ext-link xlink:href="https://doi.org/10.5194/egusphere-2025-4209" ext-link-type="DOI">10.5194/egusphere-2025-4209</ext-link>, 2025.</mixed-citation></ref>
      <ref id="bib1.bib33"><label>33</label><mixed-citation>Tavakoli, F. and Olfert, J. S.: Determination of particle mass, effective density, mass-mobility exponent, and dynamic shape factor using an aerodynamic aerosol classifier and a differential mobility analyzer in tandem, J. Aerosol Sci., 75, 35–42, <ext-link xlink:href="https://doi.org/10.1016/j.jaerosci.2014.04.010" ext-link-type="DOI">10.1016/j.jaerosci.2014.04.010</ext-link>, 2014.</mixed-citation></ref>
      <ref id="bib1.bib34"><label>34</label><mixed-citation>Virkkula, A., Mäkelä, T., Hillamo, R., Yli-Tuomi, T., Hirsikko, A., Hämeri, K., and Koponen, I. K.: A simple procedure for correcting loading effects of aethalometer data, J. Air Waste Manage. Assoc., 57, 1214–1222, <ext-link xlink:href="https://doi.org/10.3155/1047-3289.57.10.1214" ext-link-type="DOI">10.3155/1047-3289.57.10.1214</ext-link>, 2007.</mixed-citation></ref>
      <ref id="bib1.bib35"><label>35</label><mixed-citation>Weingartner, E., Saathoff, H., Schnaiter, M., Streit, N., Bitnar, B., and Baltensperger, U.: Absorption of light by soot particles: Determination of the absorption coefficient by means of aethalometers, J. Aerosol Sci., 34, 1445–1463, <ext-link xlink:href="https://doi.org/10.1016/S0021-8502(03)00359-8" ext-link-type="DOI">10.1016/S0021-8502(03)00359-8</ext-link>, 2003.</mixed-citation></ref>
      <ref id="bib1.bib36"><label>36</label><mixed-citation>Wu, L., Shen, Y., Che, F., Zhang, Y., Gao, J., and Wang, C.: Evaluating the performance and influencing factors of three portable black carbon monitors for field measurement, J. Environ. Sci. (China), 139, 320–333, <ext-link xlink:href="https://doi.org/10.1016/j.jes.2023.05.044" ext-link-type="DOI">10.1016/j.jes.2023.05.044</ext-link>, 2024.</mixed-citation></ref>
      <ref id="bib1.bib37"><label>37</label><mixed-citation>Yon, J., Bescond, A., and Ouf, F. X.: A simple semi-empirical model for effective density measurements of fractal aggregates, J. Aerosol Sci., 87, 28–37, <ext-link xlink:href="https://doi.org/10.1016/j.jaerosci.2015.05.003" ext-link-type="DOI">10.1016/j.jaerosci.2015.05.003</ext-link>, 2015.</mixed-citation></ref>

  </ref-list></back>
    <!--<article-title-html>Evaluation of mass measurement techniques for soot with different size distributions and OC&thinsp;∕&thinsp;TC contents</article-title-html>
<abstract-html/>
<ref-html id="bib1.bib1"><label>1</label><mixed-citation>
      
Aakko-Saksa, P., Kuittinen, N., Murtonen, T., Koponen, P., Aurela, M., Järvinen, A., Teinilä, K., Saarikoski, S., Barreira, L. M. F., Salo, L., Karjalainen, P., Ortega, I. K., Delhaye, D., Lehtoranta, K., Vesala, H., Jalava, P., Rönkkö, T., and Timonen, H.:
Suitability of different methods for measuring black carbon emissions from marine engines, Atmosphere (Basel), 13, <a href="https://doi.org/10.3390/atmos13010031" target="_blank">https://doi.org/10.3390/atmos13010031</a>, 2022.

    </mixed-citation></ref-html>
<ref-html id="bib1.bib2"><label>2</label><mixed-citation>
      
Allen, G., Sioutas, C., Koutrakis, P., Reiss, R., Lurmann, F. W., and Roberts, P. T.:
Evaluation of the TEOM<span style="position:relative; bottom:0.5em; " class="text">®</span> Method for Measurement of Ambient Particulate Mass in Urban Areas, J. Air Waste Manage. Assoc., 47, 682–689, <a href="https://doi.org/10.1080/10473289.1997.10463923" target="_blank">https://doi.org/10.1080/10473289.1997.10463923</a>, 1997.

    </mixed-citation></ref-html>
<ref-html id="bib1.bib3"><label>3</label><mixed-citation>
      
Arnott, W. P., Hamasha, K., Moosmüller, H., Sheridan, P. J., and Ogren, J. A.: Towards Aerosol Light-Absorption Measurements with a 7-Wavelength Aethalometer: Evaluation with a Photoacoustic Instrument and 3-Wavelength Nephelometer, Aerosol Sci. Tech., 39, 17–29, <a href="https://doi.org/10.1080/027868290901972" target="_blank">https://doi.org/10.1080/027868290901972</a>, 2005.

    </mixed-citation></ref-html>
<ref-html id="bib1.bib4"><label>4</label><mixed-citation>
      
Bescond, A., Yon, J., Ouf, F. X., Rozé, C., Coppalle, A., Parent, P., Ferry, D., and Laffon, C.:
Soot optical properties determined by analyzing extinction spectra in the visible near-UV: Toward an optical speciation according to constituents and structure, J. Aerosol Sci., 101, 118–132, <a href="https://doi.org/10.1016/j.jaerosci.2016.08.001" target="_blank">https://doi.org/10.1016/j.jaerosci.2016.08.001</a>, 2016.

    </mixed-citation></ref-html>
<ref-html id="bib1.bib5"><label>5</label><mixed-citation>
      
Blanco-Donado, E. P., Schneider, I. L., Artaxo, P., Lozano-Osorio, J., Portz, L., and Oliveira, M. L. S.:
Source identification and global implications of black carbon, Geoscience Frontiers, 13, 101149, <a href="https://doi.org/10.1016/J.GSF.2021.101149" target="_blank">https://doi.org/10.1016/J.GSF.2021.101149</a>, 2022.

    </mixed-citation></ref-html>
<ref-html id="bib1.bib6"><label>6</label><mixed-citation>
      
Chakraborty, M., Giang, A., and Zimmerman, N.:
Performance evaluation of portable dual-spot micro-aethalometers for source identification of black carbon aerosols: application to wildfire smoke and traffic emissions in the Pacific Northwest, Atmos. Meas. Tech., 16, 2333–2352, <a href="https://doi.org/10.5194/amt-16-2333-2023" target="_blank">https://doi.org/10.5194/amt-16-2333-2023</a>, 2023.

    </mixed-citation></ref-html>
<ref-html id="bib1.bib7"><label>7</label><mixed-citation>
      
Chow, J. C., Watson, J. G., Crow, D., Lowenthal, D. H., and Merrifield, T.:
Comparison of IMPROVE and NIOSH Carbon Measurements, Aerosol Science and Technology, 34, 23–34, <a href="https://doi.org/10.1080/02786820119073" target="_blank">https://doi.org/10.1080/02786820119073</a>, 2001.

    </mixed-citation></ref-html>
<ref-html id="bib1.bib8"><label>8</label><mixed-citation>
      
Collaud Coen, M., Weingartner, E., Apituley, A., Ceburnis, D., Fierz-Schmidhauser, R., Flentje, H., Henzing, J. S., Jennings, S. G., Moerman, M., Petzold, A., Schmid, O., and Baltensperger, U.:
Minimizing light absorption measurement artifacts of the Aethalometer: evaluation of five correction algorithms, Atmos. Meas. Tech., 3, 457–474, <a href="https://doi.org/10.5194/amt-3-457-2010" target="_blank">https://doi.org/10.5194/amt-3-457-2010</a>, 2010.

    </mixed-citation></ref-html>
<ref-html id="bib1.bib9"><label>9</label><mixed-citation>
      
Drinovec, L., Močnik, G., Zotter, P., Prévôt, A. S. H., Ruckstuhl, C., Coz, E., Rupakheti, M., Sciare, J., Müller, T., Wiedensohler, A., and Hansen, A. D. A.:
The “dual-spot” Aethalometer: an improved measurement of aerosol black carbon with real-time loading compensation, Atmos. Meas. Tech., 8, 1965–1979, <a href="https://doi.org/10.5194/amt-8-1965-2015" target="_blank">https://doi.org/10.5194/amt-8-1965-2015</a>, 2015.

    </mixed-citation></ref-html>
<ref-html id="bib1.bib10"><label>10</label><mixed-citation>
      
Elomaa, J. T., Luoma, K., Harni, S. D., Virkkula, A., Timonen, H., and Petäjä, T.:
The applicability and challenges of black carbon sensors in monitoring networks, Aerosol Research, 3, 293–314, <a href="https://doi.org/10.5194/ar-3-293-2025" target="_blank">https://doi.org/10.5194/ar-3-293-2025</a>, 2025.

    </mixed-citation></ref-html>
<ref-html id="bib1.bib11"><label>11</label><mixed-citation>
      
Favez, O., Cachier, H., Sciare, J., and Le Moullec, Y.:
Characterization and contribution to PM<sub>2.5</sub> of semi-volatile aerosols in Paris (France), Atmos. Environ., 41, 7969–7976, <a href="https://doi.org/10.1016/j.atmosenv.2007.09.031" target="_blank">https://doi.org/10.1016/j.atmosenv.2007.09.031</a>, 2007.

    </mixed-citation></ref-html>
<ref-html id="bib1.bib12"><label>12</label><mixed-citation>
      
Ghazi, R., Tjong, H., Soewono, A., Rogak, S. N., and Olfert, J. S.:
Mass, mobility, volatility, and morphology of soot particles generated by a mckenna and inverted burner, Aerosol Science and Technology, 47, 395–405, <a href="https://doi.org/10.1080/02786826.2012.755259" target="_blank">https://doi.org/10.1080/02786826.2012.755259</a>, 2013.

    </mixed-citation></ref-html>
<ref-html id="bib1.bib13"><label>13</label><mixed-citation>
      
Gren, L., Krais, A. M., Assarsson, E., Broberg, K., Engfeldt, M., Lindh, C., Strandberg, B., Pagels, J., and Hedmer, M.:
Underground emissions and miners' personal exposure to diesel and renewable diesel exhaust in a Swedish iron ore mine, Int. Arch. Occup. Environ. Health, 95, 1369–1388, <a href="https://doi.org/10.1007/s00420-022-01843-x" target="_blank">https://doi.org/10.1007/s00420-022-01843-x</a>, 2022.

    </mixed-citation></ref-html>
<ref-html id="bib1.bib14"><label>14</label><mixed-citation>
      
Gundel, L. A., Dod, R. L., Rosen, H., and Novakov, T.:
The relationship between optical attenuation and black carbon concentration for ambient and source particles, Science of The Total Environment, 36, 197–202, <a href="https://doi.org/10.1016/0048-9697(84)90266-3" target="_blank">https://doi.org/10.1016/0048-9697(84)90266-3</a>, 1984.

    </mixed-citation></ref-html>
<ref-html id="bib1.bib15"><label>15</label><mixed-citation>
      
Hansen, A. D. A., Rosen, H., and Novakov, T.:
The aethalometer — An instrument for the real-time measurement of optical absorption by aerosol particles, Science of The Total Environment, 36, 191–196, <a href="https://doi.org/10.1016/0048-9697(84)90265-1" target="_blank">https://doi.org/10.1016/0048-9697(84)90265-1</a>, 1984.

    </mixed-citation></ref-html>
<ref-html id="bib1.bib16"><label>16</label><mixed-citation>
      
Jung, H. and Kittelson, D. B.:
Characterization of aerosol surface instruments in transition regime, Aerosol Science and Technology, 39, 902–911, <a href="https://doi.org/10.1080/02786820500295701" target="_blank">https://doi.org/10.1080/02786820500295701</a>, 2005.

    </mixed-citation></ref-html>
<ref-html id="bib1.bib17"><label>17</label><mixed-citation>
      
Kort, A., Ouf, F. X., Gelain, T., Malet, J., Lakhmi, R., Breuil, P., and Viricelle, J. P.:
Quantification of soot deposit on a resistive sensor: Proposal of an experimental calibration protocol, J. Aerosol Sci., 156, <a href="https://doi.org/10.1016/j.jaerosci.2021.105783" target="_blank">https://doi.org/10.1016/j.jaerosci.2021.105783</a>, 2021.

    </mixed-citation></ref-html>
<ref-html id="bib1.bib18"><label>18</label><mixed-citation>
      
Kort, A., Ouf, F. X., Lakhmi, R., Gelain, T., Malet, J., Breuil, P., and Viricelle, J. P.: An Innovative Method for Soot Deposit Quantification Using a CO2 Sensor: Application to Fire Studies in Research Facilities, J. Aerosol Sci., 164, <a href="https://doi.org/10.1016/j.jaerosci.2022.106005" target="_blank">https://doi.org/10.1016/j.jaerosci.2022.106005</a>, 2022.

    </mixed-citation></ref-html>
<ref-html id="bib1.bib19"><label>19</label><mixed-citation>
      
Marhaba, I., Ferry, D., Laffon, C., Regier, T. Z., Ouf, F. X., and Parent, P.:
Aircraft and MiniCAST soot at the nanoscale, Combust. Flame, 204, 278–289, <a href="https://doi.org/10.1016/j.combustflame.2019.03.018" target="_blank">https://doi.org/10.1016/j.combustflame.2019.03.018</a>, 2019.

    </mixed-citation></ref-html>
<ref-html id="bib1.bib20"><label>20</label><mixed-citation>
      
Maricq, M. M.:
Monitoring Motor vehicle pm emissions: An evaluation of three portable low-cost aerosol instruments, Aerosol Science and Technology, 47, 564–573, <a href="https://doi.org/10.1080/02786826.2013.773394" target="_blank">https://doi.org/10.1080/02786826.2013.773394</a>, 2013.

    </mixed-citation></ref-html>
<ref-html id="bib1.bib21"><label>21</label><mixed-citation>
      
Maricq, M. M. and Xu, N.:
The effective density and fractal dimension of soot particles from premixed flames and motor vehicle exhaust, J. Aerosol Sci., 35, 1251–1274, <a href="https://doi.org/10.1016/j.jaerosci.2004.05.002" target="_blank">https://doi.org/10.1016/j.jaerosci.2004.05.002</a>, 2004.

    </mixed-citation></ref-html>
<ref-html id="bib1.bib22"><label>22</label><mixed-citation>
      
Mendoza, D. L., Hill, L. D., Blair, J., and Crosman, E. T.:
A Long-Term Comparison between the AethLabs MA350 and Aerosol Magee Scientific AE33 Black Carbon Monitors in the Greater Salt Lake City Metropolitan Area, Sensors, 24, <a href="https://doi.org/10.3390/s24030965" target="_blank">https://doi.org/10.3390/s24030965</a>, 2024.

    </mixed-citation></ref-html>
<ref-html id="bib1.bib23"><label>23</label><mixed-citation>
      
Moore, R. H., Ziemba, L. D., Dutcher, D., Beyersdorf, A. J., Chan, K., Crumeyrolle, S., Raymond, T. M., Thornhill, K. L., Winstead, E. L., and Anderson, B. E.:
Mapping the operation of the miniature combustion aerosol standard (Mini-CAST) soot generator, Aerosol Science and Technology, 48, 467–479, <a href="https://doi.org/10.1080/02786826.2014.890694" target="_blank">https://doi.org/10.1080/02786826.2014.890694</a>, 2014.

    </mixed-citation></ref-html>
<ref-html id="bib1.bib24"><label>24</label><mixed-citation>
      
Ntziachristos, L., Giechaskiel, B., Ristimäki, J., and Keskinen, J.:
Use of a corona charger for the characterisation of automotive exhaust aerosol, J. Aerosol Sci., 35, 943–963, <a href="https://doi.org/10.1016/j.jaerosci.2004.02.005" target="_blank">https://doi.org/10.1016/j.jaerosci.2004.02.005</a>, 2004.

    </mixed-citation></ref-html>
<ref-html id="bib1.bib25"><label>25</label><mixed-citation>
      
Ntziachristos, L., Amanatidis, S., Samaras, Z., Janka, K., and Tikkanen, J.:
Application of the Pegasor Particle Sensor for the Measurement of Mass and Particle Number Emissions, SAE Int. J. Fuels Lubr., 6, 521–531, <a href="https://doi.org/10.4271/2013-01-1561" target="_blank">https://doi.org/10.4271/2013-01-1561</a>, 2013.

    </mixed-citation></ref-html>
<ref-html id="bib1.bib26"><label>26</label><mixed-citation>
      
Olfert, J. and Rogak, S.:
Universal relations between soot effective density and primary particle size for common combustion sources, Aerosol Sci. Tech., 53, 485–492, <a href="https://doi.org/10.1080/02786826.2019.1577949" target="_blank">https://doi.org/10.1080/02786826.2019.1577949</a>, 2019.

    </mixed-citation></ref-html>
<ref-html id="bib1.bib27"><label>27</label><mixed-citation>
      
Ouf, F. X., Parent, P., Laffon, C., Marhaba, I., Ferry, D., Marcillaud, B., Antonsson, E., Benkoula, S., Liu, X. J., Nicolas, C., Robert, E., Patanen, M., Barreda, F. A., Sublemontier, O., Coppalle, A., Yon, J., Miserque, F., Mostefaoui, T., Regier, T. Z., Mitchell, J. B. A., and Miron, C.:
First in-flight synchrotron X-ray absorption and photoemission study of carbon soot nanoparticles, Sci. Rep., 6, <a href="https://doi.org/10.1038/srep36495" target="_blank">https://doi.org/10.1038/srep36495</a>, 2016.


    </mixed-citation></ref-html>
<ref-html id="bib1.bib28"><label>28</label><mixed-citation>
      
Ouf, F. X., Bourrous, S., Fauvel, S., Kort, A., Lintis, L., Nuvoli, J., and Yon, J.:
True density of combustion emitted particles: A comparison of results highlighting the influence of the organic contents, J. Aerosol Sci., 134, 1–13, <a href="https://doi.org/10.1016/j.jaerosci.2019.04.007" target="_blank">https://doi.org/10.1016/j.jaerosci.2019.04.007</a>, 2019.

    </mixed-citation></ref-html>
<ref-html id="bib1.bib29"><label>29</label><mixed-citation>
      
Pandis, S. N., Baltensperger, U., Wolfenbarger, J. K., and Seinfeld, J. H.:
Inversion of aerosol data from the epiphaniometer, J. Aerosol Sci., 22, 417–428, <a href="https://doi.org/10.1016/0021-8502(91)90002-Y" target="_blank">https://doi.org/10.1016/0021-8502(91)90002-Y</a>, 1991.

    </mixed-citation></ref-html>
<ref-html id="bib1.bib30"><label>30</label><mixed-citation>
      
Park, K., Kittelson, D. B., and McMurry, P. H.:
Structural properties of diesel exhaust particles measured by Transmission Electron Microscopy (TEM): Relationships to particle mass and mobility, Aerosol Science and Technology, 38, 881–889, <a href="https://doi.org/10.1080/027868290505189" target="_blank">https://doi.org/10.1080/027868290505189</a>, 2004.

    </mixed-citation></ref-html>
<ref-html id="bib1.bib31"><label>31</label><mixed-citation>
      
Rostedt, A., Arffman, A., Janka, K., Yli-Ojanperä, J., and Keskinen, J.:
Characterization and response model of the PPS-M aerosol sensor, Aerosol Science and Technology, 48, 1022–1030, <a href="https://doi.org/10.1080/02786826.2014.951023" target="_blank">https://doi.org/10.1080/02786826.2014.951023</a>, 2014.

    </mixed-citation></ref-html>
<ref-html id="bib1.bib32"><label>32</label><mixed-citation>
      
Sipkens, T. A., Corbin, J. C., Chen, K., Rivellini, L.-H., Abbatt, J., and Olfert, J. S.:
Quantitative uncertainty and post-processing for micro-aethalometers measuring black carbon, EGUsphere [preprint], <a href="https://doi.org/10.5194/egusphere-2025-4209" target="_blank">https://doi.org/10.5194/egusphere-2025-4209</a>, 2025.

    </mixed-citation></ref-html>
<ref-html id="bib1.bib33"><label>33</label><mixed-citation>
      
Tavakoli, F. and Olfert, J. S.:
Determination of particle mass, effective density, mass-mobility exponent, and dynamic shape factor using an aerodynamic aerosol classifier and a differential mobility analyzer in tandem, J. Aerosol Sci., 75, 35–42, <a href="https://doi.org/10.1016/j.jaerosci.2014.04.010" target="_blank">https://doi.org/10.1016/j.jaerosci.2014.04.010</a>, 2014.

    </mixed-citation></ref-html>
<ref-html id="bib1.bib34"><label>34</label><mixed-citation>
      
Virkkula, A., Mäkelä, T., Hillamo, R., Yli-Tuomi, T., Hirsikko, A., Hämeri, K., and Koponen, I. K.:
A simple procedure for correcting loading effects of aethalometer data, J. Air Waste Manage. Assoc., 57, 1214–1222, <a href="https://doi.org/10.3155/1047-3289.57.10.1214" target="_blank">https://doi.org/10.3155/1047-3289.57.10.1214</a>, 2007.

    </mixed-citation></ref-html>
<ref-html id="bib1.bib35"><label>35</label><mixed-citation>
      
Weingartner, E., Saathoff, H., Schnaiter, M., Streit, N., Bitnar, B., and Baltensperger, U.:
Absorption of light by soot particles: Determination of the absorption coefficient by means of aethalometers, J. Aerosol Sci., 34, 1445–1463, <a href="https://doi.org/10.1016/S0021-8502(03)00359-8" target="_blank">https://doi.org/10.1016/S0021-8502(03)00359-8</a>, 2003.

    </mixed-citation></ref-html>
<ref-html id="bib1.bib36"><label>36</label><mixed-citation>
      
Wu, L., Shen, Y., Che, F., Zhang, Y., Gao, J., and Wang, C.:
Evaluating the performance and influencing factors of three portable black carbon monitors for field measurement, J. Environ. Sci. (China), 139, 320–333, <a href="https://doi.org/10.1016/j.jes.2023.05.044" target="_blank">https://doi.org/10.1016/j.jes.2023.05.044</a>, 2024.

    </mixed-citation></ref-html>
<ref-html id="bib1.bib37"><label>37</label><mixed-citation>
      
Yon, J., Bescond, A., and Ouf, F. X.:
A simple semi-empirical model for effective density measurements of fractal aggregates, J. Aerosol Sci., 87, 28–37, <a href="https://doi.org/10.1016/j.jaerosci.2015.05.003" target="_blank">https://doi.org/10.1016/j.jaerosci.2015.05.003</a>, 2015.