<?xml version="1.0" encoding="UTF-8"?>
<!DOCTYPE article PUBLIC "-//NLM//DTD Journal Publishing with OASIS Tables v3.0 20080202//EN" "https://jats.nlm.nih.gov/nlm-dtd/publishing/3.0/journalpub-oasis3.dtd">
<article xmlns:xlink="http://www.w3.org/1999/xlink" xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:oasis="http://docs.oasis-open.org/ns/oasis-exchange/table" xml:lang="en" dtd-version="3.0" article-type="research-article">
  <front>
    <journal-meta><journal-id journal-id-type="publisher">AR</journal-id><journal-title-group>
    <journal-title>Aerosol Research</journal-title>
    <abbrev-journal-title abbrev-type="publisher">AR</abbrev-journal-title><abbrev-journal-title abbrev-type="nlm-ta">Aerosol Research</abbrev-journal-title>
  </journal-title-group><issn pub-type="epub">2940-3391</issn><publisher>
    <publisher-name>Copernicus Publications</publisher-name>
    <publisher-loc>Göttingen, Germany</publisher-loc>
  </publisher></journal-meta>
    <article-meta>
      <article-id pub-id-type="doi">10.5194/ar-4-255-2026</article-id><title-group><article-title>An intercomparison study of optical particle size spectrometers for aerosol number size  distribution measurements</article-title><alt-title>Optical particle size spectrometers for aerosol number size distribution measurements</alt-title>
      </title-group>
      <contrib-group>
        <contrib contrib-type="author" corresp="yes" rid="aff1">
          <name><surname>Bau</surname><given-names>Sébastien</given-names></name>
          <email>sebastien.bau@inrs.fr</email>
        <ext-link>https://orcid.org/0000-0003-0585-1931</ext-link></contrib>
        <contrib contrib-type="author" corresp="no" rid="aff2">
          <name><surname>Crenn</surname><given-names>Vincent</given-names></name>
          
        </contrib>
        <contrib contrib-type="author" corresp="no" rid="aff2">
          <name><surname>Leglise</surname><given-names>Joris</given-names></name>
          
        </contrib>
        <contrib contrib-type="author" corresp="no" rid="aff3">
          <name><surname>Jacquinot</surname><given-names>Sébastien</given-names></name>
          
        <ext-link>https://orcid.org/0000-0001-9625-0618</ext-link></contrib>
        <contrib contrib-type="author" corresp="no" rid="aff4">
          <name><surname>Debert</surname><given-names>Christophe</given-names></name>
          
        </contrib>
        <contrib contrib-type="author" corresp="no" rid="aff5">
          <name><surname>Petitprez</surname><given-names>Denis</given-names></name>
          
        </contrib>
        <contrib contrib-type="author" corresp="no" rid="aff5">
          <name><surname>Bizet</surname><given-names>Valentine</given-names></name>
          
        </contrib>
        <contrib contrib-type="author" corresp="no" rid="aff6">
          <name><surname>Leclerc</surname><given-names>Lara</given-names></name>
          
        <ext-link>https://orcid.org/0000-0002-3467-659X</ext-link></contrib>
        <contrib contrib-type="author" corresp="no" rid="aff7">
          <name><surname>Miffre</surname><given-names>Alain</given-names></name>
          
        <ext-link>https://orcid.org/0000-0003-1296-2349</ext-link></contrib>
        <contrib contrib-type="author" corresp="no" rid="aff7">
          <name><surname>Cholleton</surname><given-names>Danael</given-names></name>
          
        <ext-link>https://orcid.org/0000-0003-2358-3467</ext-link></contrib>
        <contrib contrib-type="author" corresp="no" rid="aff8">
          <name><surname>Rose</surname><given-names>Alec</given-names></name>
          
        </contrib>
        <contrib contrib-type="author" corresp="no" rid="aff9">
          <name><surname>Tomas</surname><given-names>Alexandre</given-names></name>
          
        </contrib>
        <contrib contrib-type="author" corresp="no" rid="aff10">
          <name><surname>Kort</surname><given-names>Amel</given-names></name>
          
        </contrib>
        <contrib contrib-type="author" corresp="no" rid="aff11">
          <name><surname>Hebert</surname><given-names>Didier</given-names></name>
          
        </contrib>
        <contrib contrib-type="author" corresp="no" rid="aff12">
          <name><surname>Joubert</surname><given-names>Aurélie</given-names></name>
          
        </contrib>
        <contrib contrib-type="author" corresp="no" rid="aff13">
          <name><surname>Deschamps</surname><given-names>Florence</given-names></name>
          
        </contrib>
        <contrib contrib-type="author" corresp="no" rid="aff14">
          <name><surname>Ritoux</surname><given-names>Sébastien</given-names></name>
          
        </contrib>
        <contrib contrib-type="author" corresp="no" rid="aff15">
          <name><surname>Ait Ali Yahia</surname><given-names>Lyes</given-names></name>
          
        </contrib>
        <contrib contrib-type="author" corresp="no" rid="aff16 aff17">
          <name><surname>Gaie-Levrel</surname><given-names>François</given-names></name>
          
        <ext-link>https://orcid.org/0000-0002-3960-1642</ext-link></contrib>
        <aff id="aff1"><label>1</label><institution>Institut national de recherche et de sécurité, INRS, Laboratoire de métrologie des aérosols,  54500 Vandoeuvre les Nancy, France</institution>
        </aff>
        <aff id="aff2"><label>2</label><institution>ADDAIR, 78530 Buc, France</institution>
        </aff>
        <aff id="aff3"><label>3</label><institution>Commissariat à l'énergie atomique et aux énergies alternatives, CEA, Laboratoire de mesures,  sécurisation et environnement, 38054 Grenoble CEDEX 9, France</institution>
        </aff>
        <aff id="aff4"><label>4</label><institution>Airparif, Laboratoire de métrologie et innovation, 75004 Paris, France</institution>
        </aff>
        <aff id="aff5"><label>5</label><institution>Université de Lille, CNRS, UMR8522 – Physico-chimie des processus de combustion  et de l'atmosphère, PC2A, 59000 Lille, France</institution>
        </aff>
        <aff id="aff6"><label>6</label><institution>Mines Saint-Etienne, Université Jean Monnet, INSERM, U1059 Sainbiose; Centre CIS,  42023 Saint-Etienne, France</institution>
        </aff>
        <aff id="aff7"><label>7</label><institution>Institut Lumière Matière, ILM, UMR 5306 CNRS/Université de Lyon, 69622 Villeurbanne CEDEX, France</institution>
        </aff>
        <aff id="aff8"><label>8</label><institution>Service des laboratoires de santé environnementale, Laboratoire polluants chimiques, 75013 Paris, France</institution>
        </aff>
        <aff id="aff9"><label>9</label><institution>Institut Mines-Télécom, Université de Lille, Center for energy and environment, 59000 Lille, France</institution>
        </aff>
        <aff id="aff10"><label>10</label><institution>Autorité de sûreté nucléaire et de radioprotection, ASNR, PSN-RES/SCA/LPMA, 91400 Saclay, France</institution>
        </aff>
        <aff id="aff11"><label>11</label><institution>Autorité de sûreté nucléaire et de radioprotection, ASNR, Laboratoire expérimental de recherche et d'expertise sur les transferts des radionucléides dans le milieu atmosphérique,   50130 Cherbourg En Cotentin, France</institution>
        </aff>
        <aff id="aff12"><label>12</label><institution>Institut Mines-Telecom Atlantique, Génie des procédés pour les écotechnologies et les bioressources, GEPEA, CNRS UMR 6144, BP 20722, 44307 Nantes CEDEX 3, France</institution>
        </aff>
        <aff id="aff13"><label>13</label><institution>Direction générale de l'armement, DGA, Maîtrise NRBC, 91710 Vert-le-Petit, France</institution>
        </aff>
        <aff id="aff14"><label>14</label><institution>Centre scientifique et technique du bâtiment, CSTB, Direction santé confort,  77447 Marne-la-Vallée CEDEX 2, France</institution>
        </aff>
        <aff id="aff15"><label>15</label><institution>Centre d'études et de recherche en thermique, environnement et systèmes, CERTES,  Université Paris-Est Créteil, 94010 Créteil, France</institution>
        </aff>
        <aff id="aff16"><label>16</label><institution>Laboratoire national de métrologie et d'essais, LNE, Direction de la métrologie scientifique et industrielle, 75724 Paris CEDEX 15, France</institution>
        </aff>
        <aff id="aff17"><label>a</label><institution>now at: Airparif, The air quality observatory for the Paris region, 7 rue Crillon, 75004, Paris, France</institution>
        </aff>
      </contrib-group>
      <author-notes><corresp id="corr1">Sébastien Bau (sebastien.bau@inrs.fr)</corresp></author-notes><pub-date><day>19</day><month>June</month><year>2026</year></pub-date>
      
      <volume>4</volume>
      <issue>1</issue>
      <fpage>255</fpage><lpage>264</lpage>
      <history>
        <date date-type="received"><day>14</day><month>November</month><year>2025</year></date>
           <date date-type="rev-request"><day>28</day><month>November</month><year>2025</year></date>
           <date date-type="rev-recd"><day>12</day><month>May</month><year>2026</year></date>
           <date date-type="accepted"><day>22</day><month>May</month><year>2026</year></date>
      </history>
      <permissions>
        <copyright-statement>Copyright: © 2026 Sébastien Bau et al.</copyright-statement>
        <copyright-year>2026</copyright-year>
      <license license-type="open-access"><license-p>This work is licensed under the Creative Commons Attribution 4.0 International License. To view a copy of this licence, visit <ext-link ext-link-type="uri" xlink:href="https://creativecommons.org/licenses/by/4.0/">https://creativecommons.org/licenses/by/4.0/</ext-link></license-p></license></permissions><self-uri xlink:href="https://ar.copernicus.org/articles/4/255/2026/ar-4-255-2026.html">This article is available from https://ar.copernicus.org/articles/4/255/2026/ar-4-255-2026.html</self-uri><self-uri xlink:href="https://ar.copernicus.org/articles/4/255/2026/ar-4-255-2026.pdf">The full text article is available as a PDF file from https://ar.copernicus.org/articles/4/255/2026/ar-4-255-2026.pdf</self-uri>
      <abstract><title>Abstract</title>

      <p id="d2e374">An inter-laboratory comparison (ILC) involving optical particle size spectrometers (OPSSs) was organised at the French national level. The aim of this study was to make an inventory of the metrological capabilities of particle number size distribution (PNSD) measurements using OPSSs. This laboratory study was conducted over an 18-month period and involved 16 partners and 35 OPSSs. This large number of instruments provides strong statistical weight to the dataset, offering robust insight into the overall instrumental capabilities of accurately and reliably measuring PNSD. For that, each partner applied the same pre-defined experimental protocol to the OPSS(s) to be tested, operated together with a common control OPSS. Three different test aerosols were involved, and their PNSDs were measured: (1) a monodisperse amorphous silica sample, (2) glass beads, and (3) a green cornstarch powder. This article presents the measured PNSD using the 35 OPSSs associated with the description of the experimental set-up, sample preparation protocol, and comparison with scanning electron microscopy measurements.</p>
  </abstract>
    </article-meta>
  </front>
<body>
      

<sec id="Ch1.S1" sec-type="intro">
  <label>1</label><title>Introduction</title>
      <p id="d2e386">Optical particle size spectrometers (OPSSs) are widely used to measure particle number size distributions. Their response is based on the light scattered by particles, which occurs when a laser beam of defined wavelength interacts with focused particles. Each resulting detected scattered laser pulse corresponds to the occurrence of a particle, which allows temporal monitoring of the particle number concentration. The intensity of the scattered light at a given scattering angle is then analysed for each pulse to evaluate particle size. The latter is therefore expressed as an optical equivalent diameter (<inline-formula><mml:math id="M1" display="inline"><mml:mrow><mml:msub><mml:mi>d</mml:mi><mml:mi mathvariant="normal">opt</mml:mi></mml:msub></mml:mrow></mml:math></inline-formula>) which corresponds to the diameter of a spherical particle that scatters the same light intensity as the one scattered by a particle of a given refractive index, thus applying the Mie theory. As a result, after calibration by applying the Mie theory, OPSSs allow particle number size distribution (PNSD) measurements in real-time for particle sizes ranging from <inline-formula><mml:math id="M2" display="inline"><mml:mo>∼</mml:mo></mml:math></inline-formula> 200 nm up to <inline-formula><mml:math id="M3" display="inline"><mml:mo>∼</mml:mo></mml:math></inline-formula> 10 <inline-formula><mml:math id="M4" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">µ</mml:mi></mml:mrow></mml:math></inline-formula>m. Their wide measurement range and fast response time make them well suited for ground-based measurements, as well as for aircraft measurements (Ortega et al., 2019). More recently, these instruments have also been increasingly used for workplace and indoor air quality monitoring (Maragkidou et al., 2018). However, these optical methods are dependent on particle size, shape, and refractive index. Accurate light-scattering theories do not exist for complex particles, for which the Mie theory appears as an approximation (Mishchenko et al., 2002). For this reason, downstream use of calibration factors is required, e.g. for converting number size distributions into mass concentrations.</p>
      <p id="d2e422">Accurate particle size distributions require careful calibration of the OPSS detection efficiency against primary standards for particle number concentration. Size calibration is typically performed using spherical, non-absorbing polystyrene particles with well-defined diameters and refractive indices (ISO 21501-1, 2025; ISO 21501-4, 2018). However, indoor, environmental and/or workplace aerosols consist of particles with varying shapes and sizes and complex refractive indices. Interestingly, very few OPSS inter-laboratory comparisons (ILCs) were performed over the last 50 years. In their work,  Hindman Ii et al. (1978) performed a field comparison of PNSD measurements involving six OPSSs. Systematic differences between the measurements from the various instruments were smallest for sub-micron particles by a factor of 1.5–2.5 and largest for micron particles by a factor of 8–15. More than 40 years later, Vasilatou et al. (2020) presented a first inter-laboratory comparison for low particle number concentrations dedicated to clean room facilities. Their study was conducted for particle sizes ranging from 300 nm up to 5 <inline-formula><mml:math id="M5" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">µ</mml:mi></mml:mrow></mml:math></inline-formula>m and for number concentrations up to 2 particles cm<sup>−3</sup> using polystyrene latex (PSL) spheres and sodium chloride and/or lactose monohydrate aerosols. Such ILCs involved non-transportable facilities for the use of primary methods for measuring particle number concentrations in accordance with the full requirements of the ISO 21501-4 standard (Horender et al., 2019; ISO 21501-4, 2018). For that reason, the authors used OPSSs as transfer standards that were shipped to all participants. They showed that all particle sizes agreed with the reference value within 7 % and were therefore compatible with the stated uncertainties. Meanwhile, Iida and Sakurai (2018) presented a new methodology for evaluating the OPSS counting efficiencies based on an ink jet aerosol generator, which allowed the production of monodisperse particles at a constant rate with lactose monohydrate, ionic liquid, and sodium chloride. Nevertheless, as also stated by Vasilatou et al. (2020), the metrological basis of this study remains incomplete since the degree of equivalence was investigated by means of inter-laboratory comparisons. As a result, to the best of our knowledge, no ILC exists involving OPSSs for measuring PNSD, while such optical size spectrometers are used every day worldwide, and precision is needed when precise air quality assessment is sought.</p>
      <p id="d2e445">In this context, the present work aims to present the methodology and the results of an ILC involving a large number of OPSSs (35) for measuring PNSD by focusing on the same three test aerosols. This work does not consist of instrument calibration, but this will be considered as a possible metrological control, accounting for the statistical weight provided by the large ensemble of instruments implied. This ILC was conducted as a continuation of a previous study carried out on electrical mobility spectrometers (Gaie-Levrel et al., 2020) in which we stated that “new intercomparison studies on aerosol particle size distribution measurements will be organised by involving optical, aerodynamic, and electrical mobility sizers using a common transportable control aerosol generator circulated among participants, following an approach similar to that proposed by Gaie-Levrel et al. (2018) for particle mass concentration measurements”. We seized the opportunity of the French network, built through previous cooperations and conferences, to carry out this ILC at a national scale, thus involving 16 research groups. The overall objective of this study was to make an inventory of the metrological capabilities of various OPSS measurement techniques, with the idea to provide robust insight into their instrumental accuracy and to establish both a methodology and a first dataset for improving their reliability. Since this work is not a calibration study, no reference devices (e.g. SMPS, APS, AAC-CPC) were used for validation, and no polystyrene standards were used. Indeed, experiments were carried out using three aerosol samples: (1) a monodisperse amorphous silica sample, (2) glass beads, and (3) a green cornstarch powder. There was no intention to generate test aerosols that would be representative of specific ones, e.g. a typical urban atmospheric aerosol. Instead, one of our objectives was to investigate the possibility of producing the same aerosols in the different laboratories involved by using an accessible generation set-up using a dry-based method as this seemed to make it easier to provide the powders to all partners. To minimise biases, the dry-based aerosol generator involved in this work was identical for each partner and was completed with a common running-control OPSS.</p>
</sec>
<sec id="Ch1.S2">
  <label>2</label><title>Materials and methods</title>
<sec id="Ch1.S2.SS1">
  <label>2.1</label><title>Experimental set-up</title>
      <p id="d2e463">Inter-laboratory comparisons are usually constrained by the difficulty of moving instruments at the same location at the same time. The strategy chosen in this study was to use a unique laboratory experimental set-up, involving a common dry-aerosol generator and a control OPSS, which were sent to each participant prior to the experiments. A total of 16 partners took part in this inter-comparison exercise and received every part in order to build the experimental set-up in their own laboratories, as presented in Fig. 1.</p>

      <fig id="F1"><label>Figure 1</label><caption><p id="d2e468">Experimental set-up used by each partner for this study.</p></caption>
          <graphic xlink:href="https://ar.copernicus.org/articles/4/255/2026/ar-4-255-2026-f01.png"/>

        </fig>

      <p id="d2e477">The aerosol generator is based on the principle of a vortex shaker (VS-1000, ADDAIR, patent WO2013092816; Leglise et al., 2022). Within the generator, the filtered and dried air is injected from the upper part directly into the vortex mixer receptacle containing the powder sample to be aerosolised. The injection rod internal dimension is selected such that the flow in the receptacle is turbulent. The whole structure is connected to a vibrating motor with an eccentric mass to ensure stable and efficient agitation. The second zone, conical in shape, is subjected to an upward flow where the particles are selected according to their size by vertical elutriation. The air injection flow rate was set to be 4 L min<sup>−1</sup> for this study, and the vibration frequency was set at 60 Hz (<inline-formula><mml:math id="M8" display="inline"><mml:mo lspace="0mm">∼</mml:mo></mml:math></inline-formula> 12 V). A homogenisation volume was coupled downstream of the generator in order to smooth temporal instabilities and to dilute the produced aerosols according to the total instrumental flow rate (Fig. 1). A four-way flow splitter (TSI model 3708) was involved to allow the use of multiple instruments in parallel, including the control OPSS. The latter was used as a common control measurement device (FIDAS Mobile, PALAS) in order to provide measurements with the same instrument in each laboratory in parallel to the OPSSs tested by each partner. Through the 16 partners involved, 35 optical instruments were included in this inter-laboratory comparison, involving OPSSs with different technical specifications, as presented in Table 1. The control instrument was freshly calibrated, and its performances were verified periodically throughout the ILC exercise. The choice of the control instrument mainly relied on its availability over the ILC period, as well as its high size resolution (64 channels), as stated in Table 1. Since there was no intention of including exclusively freshly calibrated instruments, the latter were categorised according to the time delay between their last calibration and the date of the experiments. A total of 40 % of the instruments had been calibrated less than 1 year prior to the experiments, 26 % had been conducted between 1 and 2 years prior to the experiments, and 34 % had been calibrated more than 2 years prior to the experiments. To limit coincidental measurement artefacts and to allow higher particle concentrations to be measured, a controlled sheath air flow can be included in the instrument design, as stated in Table 1.</p>

<table-wrap id="T1" specific-use="star"><label>Table 1</label><caption><p id="d2e503">OPSS types implicated in the present intercomparison study.</p></caption><oasis:table frame="topbot"><oasis:tgroup cols="10">
     <oasis:colspec colnum="1" colname="col1" align="left"/>
     <oasis:colspec colnum="2" colname="col2" align="right" colsep="1"/>
     <oasis:colspec colnum="3" colname="col3" align="right"/>
     <oasis:colspec colnum="4" colname="col4" align="right"/>
     <oasis:colspec colnum="5" colname="col5" align="right"/>
     <oasis:colspec colnum="6" colname="col6" align="right" colsep="1"/>
     <oasis:colspec colnum="7" colname="col7" align="right"/>
     <oasis:colspec colnum="8" colname="col8" align="right"/>
     <oasis:colspec colnum="9" colname="col9" align="right"/>
     <oasis:colspec colnum="10" colname="col10" align="right"/>
     <oasis:thead>
       <oasis:row rowsep="1">
         <oasis:entry colname="col1"/>
         <oasis:entry colname="col2">TSI</oasis:entry>
         <oasis:entry namest="col3" nameend="col6" align="center" colsep="1">GRIMM </oasis:entry>
         <oasis:entry namest="col7" nameend="col10" align="center">PALAS </oasis:entry>
       </oasis:row>
     </oasis:thead>
     <oasis:tbody>
       <oasis:row>
         <oasis:entry colname="col1"/>
         <oasis:entry colname="col2">OPS</oasis:entry>
         <oasis:entry colname="col3"/>
         <oasis:entry colname="col4"/>
         <oasis:entry colname="col5"/>
         <oasis:entry colname="col6">Mini-Wras</oasis:entry>
         <oasis:entry colname="col7">Fidas</oasis:entry>
         <oasis:entry colname="col8">Fidas</oasis:entry>
         <oasis:entry colname="col9"/>
         <oasis:entry colname="col10">Promo/</oasis:entry>
       </oasis:row>
       <oasis:row rowsep="1">
         <oasis:entry colname="col1">Model</oasis:entry>
         <oasis:entry colname="col2">3330</oasis:entry>
         <oasis:entry colname="col3">1.108</oasis:entry>
         <oasis:entry colname="col4">1.109</oasis:entry>
         <oasis:entry colname="col5">11D</oasis:entry>
         <oasis:entry colname="col6">(optical part)</oasis:entry>
         <oasis:entry colname="col7">Mobile</oasis:entry>
         <oasis:entry colname="col8">Frog</oasis:entry>
         <oasis:entry colname="col9">Fidas 200</oasis:entry>
         <oasis:entry colname="col10">Welas</oasis:entry>
       </oasis:row>
       <oasis:row rowsep="1">
         <oasis:entry colname="col1">Wavelength (nm)</oasis:entry>
         <oasis:entry colname="col2">660</oasis:entry>
         <oasis:entry colname="col3">780</oasis:entry>
         <oasis:entry colname="col4">655</oasis:entry>
         <oasis:entry colname="col5">655</oasis:entry>
         <oasis:entry colname="col6">660</oasis:entry>
         <oasis:entry namest="col7" nameend="col10" align="center">Polychromatic </oasis:entry>
       </oasis:row>
       <oasis:row rowsep="1">
         <oasis:entry colname="col1">Detection angle (°)</oasis:entry>
         <oasis:entry colname="col2">90 <inline-formula><mml:math id="M9" display="inline"><mml:mo>±</mml:mo></mml:math></inline-formula> 60</oasis:entry>
         <oasis:entry namest="col3" nameend="col6" align="center" colsep="1">90 <inline-formula><mml:math id="M10" display="inline"><mml:mo>±</mml:mo></mml:math></inline-formula> 30 </oasis:entry>
         <oasis:entry namest="col7" nameend="col10" align="center">90 <inline-formula><mml:math id="M11" display="inline"><mml:mo>±</mml:mo></mml:math></inline-formula> 5 </oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1">Number of channels</oasis:entry>
         <oasis:entry colname="col2">16</oasis:entry>
         <oasis:entry colname="col3">15</oasis:entry>
         <oasis:entry colname="col4">31</oasis:entry>
         <oasis:entry colname="col5">31</oasis:entry>
         <oasis:entry colname="col6">31</oasis:entry>
         <oasis:entry namest="col7" nameend="col9" align="center" colsep="1">64 </oasis:entry>
         <oasis:entry colname="col10">128</oasis:entry>
       </oasis:row>
       <oasis:row rowsep="1">
         <oasis:entry colname="col1">(size range, <inline-formula><mml:math id="M12" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">µ</mml:mi></mml:mrow></mml:math></inline-formula>m)</oasis:entry>
         <oasis:entry colname="col2">(0.3–10)</oasis:entry>
         <oasis:entry colname="col3">(0.3–20)</oasis:entry>
         <oasis:entry colname="col4">(0.25–32)</oasis:entry>
         <oasis:entry colname="col5">(0.25–35)</oasis:entry>
         <oasis:entry colname="col6">(0.25–35)</oasis:entry>
         <oasis:entry namest="col7" nameend="col9" align="center" colsep="1">(0.18–18) </oasis:entry>
         <oasis:entry colname="col10">(0.2–10/0.3–17)</oasis:entry>
       </oasis:row>
       <oasis:row rowsep="1">
         <oasis:entry colname="col1">Flow rate (L min<sup>−1</sup>)</oasis:entry>
         <oasis:entry colname="col2">1</oasis:entry>
         <oasis:entry namest="col3" nameend="col6" align="center" colsep="1">1.2 </oasis:entry>
         <oasis:entry namest="col7" nameend="col8" align="center" colsep="1">1.4 </oasis:entry>
         <oasis:entry colname="col9">4.8</oasis:entry>
         <oasis:entry colname="col10">5</oasis:entry>
       </oasis:row>
       <oasis:row rowsep="1">
         <oasis:entry colname="col1">Sheath flow (L min<sup>−1</sup>)</oasis:entry>
         <oasis:entry colname="col2">1</oasis:entry>
         <oasis:entry namest="col3" nameend="col6" align="center" colsep="1">0.4 </oasis:entry>
         <oasis:entry namest="col7" nameend="col10" align="center">NA </oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1">Maximum</oasis:entry>
         <oasis:entry colname="col2"/>
         <oasis:entry colname="col3"/>
         <oasis:entry colname="col4"/>
         <oasis:entry colname="col5"/>
         <oasis:entry colname="col6"/>
         <oasis:entry colname="col7"/>
         <oasis:entry colname="col8"/>
         <oasis:entry colname="col9"/>
         <oasis:entry colname="col10">10<sup>6</sup></oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1">concentration (no. cm<sup>−3</sup>)</oasis:entry>
         <oasis:entry colname="col2">3000</oasis:entry>
         <oasis:entry namest="col3" nameend="col4" align="center">2000 </oasis:entry>
         <oasis:entry namest="col5" nameend="col6" align="center">5300 </oasis:entry>
         <oasis:entry namest="col7" nameend="col9" align="center">20 000 </oasis:entry>
         <oasis:entry colname="col10">(*) 2100: 10<sup>5</sup>,</oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1"/>
         <oasis:entry colname="col2"/>
         <oasis:entry colname="col3"/>
         <oasis:entry colname="col4"/>
         <oasis:entry colname="col5"/>
         <oasis:entry colname="col6"/>
         <oasis:entry colname="col7"/>
         <oasis:entry colname="col8"/>
         <oasis:entry colname="col9"/>
         <oasis:entry colname="col10">2300: 8000,</oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1"/>
         <oasis:entry colname="col2"/>
         <oasis:entry colname="col3"/>
         <oasis:entry colname="col4"/>
         <oasis:entry colname="col5"/>
         <oasis:entry colname="col6"/>
         <oasis:entry colname="col7"/>
         <oasis:entry colname="col8"/>
         <oasis:entry colname="col9"/>
         <oasis:entry colname="col10">2500: 800</oasis:entry>
       </oasis:row>
     </oasis:tbody>
   </oasis:tgroup></oasis:table><table-wrap-foot><p id="d2e506">(*) Maximum concentration for 10 % coincidence error depending on measurement cell reference.</p></table-wrap-foot></table-wrap>

</sec>
<sec id="Ch1.S2.SS2">
  <label>2.2</label><title>Samples, preparation protocol, and data acquisition</title>
      <p id="d2e942">Three different test aerosols were investigated: <list list-type="bullet"><list-item>
      <p id="d2e947">A monodisperse amorphous silica (Angströmsphere), 0.5 <inline-formula><mml:math id="M18" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">µ</mml:mi></mml:mrow></mml:math></inline-formula>m in size, was used as a control sample, allowing us to verify the instrumental accuracy and to adjust measurements when required. This silica sample has already been studied in the past to determine its refractive index, i.e. 1.45 (Hubert et al., 2017). This sample is hereafter labelled as the <italic>A sample</italic> or <italic>sample A</italic>.</p></list-item><list-item>
      <p id="d2e965">Glass beads, which are named Spheriglass 5000CP00 (Potters), with a refractive index in the range of 1.9 to 2.2, were used as the second sample. This sample is hereafter labelled as the <italic>B sample</italic> or <italic>sample B</italic>.</p></list-item><list-item>
      <p id="d2e975">A coloured cornstarch powder, called green Holi powder (colour people), with a refractive index around 1.6, was used as the third sample. This sample is hereafter labelled as the <italic>C sample</italic> or <italic>sample C</italic>.</p></list-item></list> While sample A consists of calibrated monodisperse particles in the low particle size range of OPSSs, sample B consists of polydisperse spherical particles with a refractive index close to the one of calibration PSL particles (1.59). Sample C is the most complex test aerosol, with polydisperse particles with non-spherical morphology. About 0.5 L of each powder (commercially available) was acquired, subsampled, provided to each participant, and stored at room temperature and protected from light. The preparation protocols for powder samples to be analysed were deliberately basic to be performed as simply as possible.</p>
      <p id="d2e985">Figure 2 shows a typical scanning electron microscopy (SEM) image of airborne particles sampled on a carbon transmission electron microscopy (TEM) grid from each aerosol produced using the experimental set-up presented in Fig. 1 and using the Mini Particle Sampler (MPS) (R'Mili et al., 2013; Xiang et al., 2021) for these three samples.</p>

      <fig id="F2" specific-use="star"><label>Figure 2</label><caption><p id="d2e990">SEM images for the three powder samples, i.e. <bold>(A)</bold> monodisperse silica, <bold>(B)</bold> glass beads, and <bold>(C)</bold> Holi powder.</p></caption>
          <graphic xlink:href="https://ar.copernicus.org/articles/4/255/2026/ar-4-255-2026-f02.jpg"/>

        </fig>

      <p id="d2e1009">From these SEM images, particle sizes were found to be 0.486 <inline-formula><mml:math id="M19" display="inline"><mml:mo>±</mml:mo></mml:math></inline-formula> 0.015 <inline-formula><mml:math id="M20" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">µ</mml:mi></mml:mrow></mml:math></inline-formula>m for monodisperse amorphous silica, 4.06 <inline-formula><mml:math id="M21" display="inline"><mml:mo>±</mml:mo></mml:math></inline-formula> 2.792 <inline-formula><mml:math id="M22" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">µ</mml:mi></mml:mrow></mml:math></inline-formula>m for Spheriglass, and 4.117 <inline-formula><mml:math id="M23" display="inline"><mml:mo>±</mml:mo></mml:math></inline-formula> 0.899 <inline-formula><mml:math id="M24" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">µ</mml:mi></mml:mrow></mml:math></inline-formula>m for Holi powder. It is worth noting that SEM measurements correspond to the geometrical diameter of particles, which may be different from the equivalent optical diameter reported by OPSSs.</p>
      <p id="d2e1058">Regarding data acquisition, each partner was required to record PNSDs with a 10 s acquisition time per sample and a total duration of 10 min. A blank measurement was performed between samples. Each participant was responsible for the use of each OPSS under “good laboratory practice” conditions, particularly by ensuring (i) the absence of internal errors reported by the devices, including coincidence errors, and (ii) the lowest particle losses through tubing that was as short and as straight as possible between the flow splitter and the OPSSs involved.</p>
</sec>
</sec>
<sec id="Ch1.S3">
  <label>3</label><title>Results and discussion</title>
<sec id="Ch1.S3.SS1">
  <label>3.1</label><title>Reference number size distributions</title>
      <p id="d2e1077">For each of the three test aerosols, all PNSDs measured by each partner with the control OPSS were used to calculate the averaged PNSD resulting from all measurements. Figure 3 presents the corresponding averaged PNSD for the three test aerosols. The presence of submicron particles for samples B and C, also visible in the SEM pictures provided in Fig. 2, could be linked to powder synthesis process or physical frictions between grains (attrition).</p>

      <fig id="F3"><label>Figure 3</label><caption><p id="d2e1082">Average relative particle number size distributions measured by the control Fidas mobile instrument for the three powder samples. Error bars correspond to calculated standard deviations.</p></caption>
          <graphic xlink:href="https://ar.copernicus.org/articles/4/255/2026/ar-4-255-2026-f03.png"/>

        </fig>

      <p id="d2e1091">PNSDs were fitted with a lognormal law (OriginPro 2023), allowing the modal diameter and geometric standard deviation to be determined for each replicate; the characteristics of the PNSDs measured by the control OPSS are given in Table 2.</p>

<table-wrap id="T2"><label>Table 2</label><caption><p id="d2e1098">The 90 % confidence intervals of the measured PNSD from the control OPSS.</p></caption><oasis:table frame="topbot"><oasis:tgroup cols="3">
     <oasis:colspec colnum="1" colname="col1" align="left"/>
     <oasis:colspec colnum="2" colname="col2" align="right"/>
     <oasis:colspec colnum="3" colname="col3" align="right"/>
     <oasis:thead>
       <oasis:row>
         <oasis:entry colname="col1"/>
         <oasis:entry colname="col2">Modal optical</oasis:entry>
         <oasis:entry colname="col3">Geometric standard</oasis:entry>
       </oasis:row>
       <oasis:row rowsep="1">
         <oasis:entry colname="col1"/>
         <oasis:entry colname="col2">diameter (<inline-formula><mml:math id="M25" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">µ</mml:mi></mml:mrow></mml:math></inline-formula>m)</oasis:entry>
         <oasis:entry colname="col3">deviation (–)</oasis:entry>
       </oasis:row>
     </oasis:thead>
     <oasis:tbody>
       <oasis:row>
         <oasis:entry colname="col1">A sample</oasis:entry>
         <oasis:entry colname="col2">0.32–0.34</oasis:entry>
         <oasis:entry colname="col3">1.09–1.12</oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1">B sample</oasis:entry>
         <oasis:entry colname="col2">1.91–3.66</oasis:entry>
         <oasis:entry colname="col3">2.10–2.50</oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1">C sample</oasis:entry>
         <oasis:entry colname="col2">3.02–4.32</oasis:entry>
         <oasis:entry colname="col3">1.65–1.97</oasis:entry>
       </oasis:row>
     </oasis:tbody>
   </oasis:tgroup></oasis:table></table-wrap>

      <p id="d2e1184">It is important to note that the default of accordance between SEM-based (Fig. 2 and Sect. 2.2) and OPSS-based modal diameter measurements can be due to the fact that SEM images provide a geometric diameter, whereas OPSSs return an equivalent optical diameter, i.e. the diameter of a particle with given refractive index that diffuses the same light intensity as the particle.</p>
</sec>
<sec id="Ch1.S3.SS2">
  <label>3.2</label><title>PNSD comparison and <inline-formula><mml:math id="M26" display="inline"><mml:mi>Z</mml:mi></mml:math></inline-formula> scoring</title>
      <p id="d2e1203">Since the total flow rate in the set-up is dependent on the number and types of OPSSs involved by each partner, it was not possible to compare the total number concentrations. For that reason, data processing and interpretation are based on the relative number size distributions (i.e. <inline-formula><mml:math id="M27" display="inline"><mml:mrow><mml:mi mathvariant="normal">d</mml:mi><mml:mi>N</mml:mi><mml:mo>/</mml:mo><mml:msub><mml:mi>N</mml:mi><mml:mi mathvariant="normal">tot</mml:mi></mml:msub><mml:mi mathvariant="normal">d</mml:mi></mml:mrow></mml:math></inline-formula> log <inline-formula><mml:math id="M28" display="inline"><mml:mrow><mml:msub><mml:mi>d</mml:mi><mml:mi mathvariant="normal">opt</mml:mi></mml:msub></mml:mrow></mml:math></inline-formula>). In this study, modal diameters and geometric standard deviations (GSDs) obtained from lognormal fits were considered, along with the corresponding determination coefficients (<inline-formula><mml:math id="M29" display="inline"><mml:mrow><mml:msup><mml:mi>R</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msup></mml:mrow></mml:math></inline-formula>) characterising the goodness of fit of the lognormal model for three different aerosols. The results are present in Fig. 4 for silica, Fig. 5 for Spheriglass, and Fig. 6 for Holi. In these figures, the grey area represents the 90 % confidence interval of both the modal diameter and GSD given in Table 2, thus providing a reference range for assessing inter-instrument agreement. Error bars presented in Figs. 4–6 for each OPSS involved correspond to the 95 % confidence interval on modal diameters and GSDs stemming from the lognormal fitting procedure.</p>

      <fig id="F4"><label>Figure 4</label><caption><p id="d2e1249">PNSD parameters (mode, GSD) and lognormal model fit quality (<inline-formula><mml:math id="M30" display="inline"><mml:mrow><mml:msup><mml:mi>R</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msup></mml:mrow></mml:math></inline-formula>) for monodisperse silica for the different instruments involved in the ILC. The grey area corresponds to the 90 % confidence interval of the parameters obtained with the control instrument.</p></caption>
          <graphic xlink:href="https://ar.copernicus.org/articles/4/255/2026/ar-4-255-2026-f04.png"/>

        </fig>

      <fig id="F5"><label>Figure 5</label><caption><p id="d2e1272">PNSD parameters (mode, GSD) and lognormal model fit quality (<inline-formula><mml:math id="M31" display="inline"><mml:mrow><mml:msup><mml:mi>R</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msup></mml:mrow></mml:math></inline-formula>) for Spheriglass particles for the different instruments involved in the ILC. The grey area corresponds to the 90 % confidence interval of the parameters obtained with the control instrument.</p></caption>
          <graphic xlink:href="https://ar.copernicus.org/articles/4/255/2026/ar-4-255-2026-f05.png"/>

        </fig>

      <fig id="F6"><label>Figure 6</label><caption><p id="d2e1294">PNSD parameters (mode, GSD) and lognormal model fit quality (<inline-formula><mml:math id="M32" display="inline"><mml:mrow><mml:msup><mml:mi>R</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msup></mml:mrow></mml:math></inline-formula>) for aerosolised Holi powder for the different instruments involved in the ILC. The grey area corresponds to the 90 % confidence interval of the parameters obtained with the control instrument.</p></caption>
          <graphic xlink:href="https://ar.copernicus.org/articles/4/255/2026/ar-4-255-2026-f06.png"/>

        </fig>

      <p id="d2e1314">For monodisperse silica (Fig. 4), the results show a high level of consistency between instruments for both the modal diameter and the GSD. Most measurements fall within or very close to the confidence interval defined by the control instrument. This limited dispersion reflects the well-controlled and stable nature of the monodisperse aerosol, which is inherently easier to characterise. The generally high <inline-formula><mml:math id="M33" display="inline"><mml:mrow><mml:msup><mml:mi>R</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msup></mml:mrow></mml:math></inline-formula> values further indicate that the lognormal model accurately represents the particle number size distribution for this type of aerosol.</p>
      <p id="d2e1328">For Spheriglass (Fig. 5), a larger variability is observed across instruments. Although several measurements remain within the confidence interval provided by the control OPSS, noticeable deviations appear, particularly for the GSD. The latter is most frequently lower for candidate instruments than for the control OPSS. Nonetheless, lower determination coefficients are also observed, suggesting that some GSDs should be considered with caution. This increased spread suggests a higher sensitivity to instrumental differences, possibly related to variations in measurement principles or particle–instrument interactions.</p>
      <p id="d2e1332">For Holi powder (Fig. 6), the variability between instruments is even more pronounced. Significant differences are observed for both the modal diameter and the GSD, with several measurements lying outside the confidence interval of the control instrument. This behaviour is consistent with the complex and polydisperse nature of Holi powder aerosols, as mentioned earlier, which are more challenging to characterise accurately. The diversity in particle size, shape, and composition likely contributes to discrepancies between instruments as different measurement techniques may respond differently to such heterogeneity. As a result, the quality of the lognormal fit (<inline-formula><mml:math id="M34" display="inline"><mml:mrow><mml:msup><mml:mi>R</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msup></mml:mrow></mml:math></inline-formula>) is expected to be more variable, reflecting deviations from an ideal lognormal distribution.</p>
      <p id="d2e1347">Overall, the comparison across these results clearly highlights the influence of aerosol complexity on measurement reproducibility. While monodisperse silica yields highly consistent and reliable results across instruments, despite its low diameter range compared to the OPSS size detection limits, Spheriglass particles introduce moderate variability, and Holi powder – due to its polydisperse and heterogeneous nature – leads to the largest discrepancies and uncertainty in the derived parameters.</p>
      <p id="d2e1350">Most measurements cluster near the control instrument, though a few outliers occur at both lower and higher values, likely reflecting differences in calibration, measurement methods, or sample handling.</p>
      <p id="d2e1353">An analysis based on the <inline-formula><mml:math id="M35" display="inline"><mml:mi>Z</mml:mi></mml:math></inline-formula>-score performance criterion (ISO 13528, 2022; Thompson et al., 2006) was conducted in order to consider both the discrepancy between the modal diameters and the variability of the control measurement. <inline-formula><mml:math id="M36" display="inline"><mml:mi>Z</mml:mi></mml:math></inline-formula> is defined as follows:

            <disp-formula id="Ch1.E1" content-type="numbered"><label>1</label><mml:math id="M37" display="block"><mml:mrow><mml:mi>Z</mml:mi><mml:mo>=</mml:mo><mml:mstyle displaystyle="true"><mml:mfrac style="display"><mml:mrow><mml:msub><mml:mi>d</mml:mi><mml:mrow><mml:msub><mml:mi mathvariant="normal">mod</mml:mi><mml:mrow><mml:msub><mml:mi mathvariant="normal">OPSS</mml:mi><mml:mi>i</mml:mi></mml:msub></mml:mrow></mml:msub></mml:mrow></mml:msub><mml:mo>-</mml:mo><mml:msub><mml:mi>d</mml:mi><mml:mrow><mml:msub><mml:mi mathvariant="normal">mod</mml:mi><mml:mi mathvariant="normal">OPSS</mml:mi></mml:msub><mml:mo>∗</mml:mo></mml:mrow></mml:msub></mml:mrow><mml:mrow><mml:mn mathvariant="normal">2</mml:mn><mml:mi mathvariant="italic">σ</mml:mi><mml:mfenced close=")" open="("><mml:mrow><mml:msub><mml:mi>d</mml:mi><mml:mrow><mml:msub><mml:mi mathvariant="normal">mod</mml:mi><mml:mi mathvariant="normal">OPSS</mml:mi></mml:msub><mml:mo>∗</mml:mo></mml:mrow></mml:msub></mml:mrow></mml:mfenced></mml:mrow></mml:mfrac></mml:mstyle><mml:mo>,</mml:mo></mml:mrow></mml:math></disp-formula>

          where <inline-formula><mml:math id="M38" display="inline"><mml:mrow><mml:msub><mml:mi>d</mml:mi><mml:mrow><mml:msub><mml:mi mathvariant="normal">mod</mml:mi><mml:mrow><mml:msub><mml:mi mathvariant="normal">OPSS</mml:mi><mml:mi>i</mml:mi></mml:msub></mml:mrow></mml:msub></mml:mrow></mml:msub></mml:mrow></mml:math></inline-formula> and <inline-formula><mml:math id="M39" display="inline"><mml:mrow><mml:msub><mml:mi>d</mml:mi><mml:mrow><mml:msub><mml:mi mathvariant="normal">mod</mml:mi><mml:mrow><mml:msup><mml:mi mathvariant="normal">OPSS</mml:mi><mml:mo>∗</mml:mo></mml:msup></mml:mrow></mml:msub></mml:mrow></mml:msub></mml:mrow></mml:math></inline-formula> represent the modal diameters from the tested OPSS and from the control measurement, respectively, and <inline-formula><mml:math id="M40" display="inline"><mml:mrow><mml:mi mathvariant="italic">σ</mml:mi><mml:mo>(</mml:mo><mml:msub><mml:mi>d</mml:mi><mml:mrow><mml:msub><mml:mi mathvariant="normal">mod</mml:mi><mml:mrow><mml:msup><mml:mi mathvariant="normal">OPSS</mml:mi><mml:mo>∗</mml:mo></mml:msup></mml:mrow></mml:msub></mml:mrow></mml:msub><mml:mo>)</mml:mo></mml:mrow></mml:math></inline-formula> represents the repeatability standard deviation calculated from all of the control measurements. Depending on the <inline-formula><mml:math id="M41" display="inline"><mml:mi>Z</mml:mi></mml:math></inline-formula> value, the measurements can then be classified into performance zones: <list list-type="bullet"><list-item>
      <p id="d2e1502"><inline-formula><mml:math id="M42" display="inline"><mml:mrow><mml:mfenced close="|" open="|"><mml:mi>Z</mml:mi></mml:mfenced><mml:mo>&gt;</mml:mo><mml:mn mathvariant="normal">3</mml:mn></mml:mrow></mml:math></inline-formula> shows unsatisfactory values (“warning zone”),</p></list-item><list-item>
      <p id="d2e1518"><inline-formula><mml:math id="M43" display="inline"><mml:mrow><mml:mn mathvariant="normal">2</mml:mn><mml:mo>&lt;</mml:mo><mml:mfenced close="|" open="|"><mml:mi>Z</mml:mi></mml:mfenced><mml:mo>≤</mml:mo><mml:mn mathvariant="normal">3</mml:mn></mml:mrow></mml:math></inline-formula> shows questionable values (“surveillance zone”),</p></list-item><list-item>
      <p id="d2e1538"><inline-formula><mml:math id="M44" display="inline"><mml:mrow><mml:mn mathvariant="normal">1</mml:mn><mml:mo>&lt;</mml:mo><mml:mfenced close="|" open="|"><mml:mi>Z</mml:mi></mml:mfenced><mml:mo>≤</mml:mo><mml:mn mathvariant="normal">2</mml:mn></mml:mrow></mml:math></inline-formula> shows coherent values and corresponds to acceptable performance,</p></list-item><list-item>
      <p id="d2e1558"><inline-formula><mml:math id="M45" display="inline"><mml:mrow><mml:mfenced close="|" open="|"><mml:mi>Z</mml:mi></mml:mfenced><mml:mo>≤</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:math></inline-formula> shows values and corresponds to excellent performance.</p></list-item></list> A similar analysis was conducted on the GSDs. According to Eq. (1), <inline-formula><mml:math id="M46" display="inline"><mml:mi>Z</mml:mi></mml:math></inline-formula> scores are mainly affected by the repeatability standard deviation <inline-formula><mml:math id="M47" display="inline"><mml:mrow><mml:mi mathvariant="italic">σ</mml:mi><mml:mo>(</mml:mo><mml:msub><mml:mi>d</mml:mi><mml:mrow><mml:msub><mml:mi mathvariant="normal">mod</mml:mi><mml:mrow><mml:msup><mml:mi mathvariant="normal">OPSS</mml:mi><mml:mo>∗</mml:mo></mml:msup></mml:mrow></mml:msub></mml:mrow></mml:msub><mml:mo>)</mml:mo></mml:mrow></mml:math></inline-formula> and, to a lesser extent, depend slightly on the choice of the control OPSS.</p>
      <p id="d2e1606">In order to better understand the <inline-formula><mml:math id="M48" display="inline"><mml:mi>Z</mml:mi></mml:math></inline-formula> scoring, each OPSS involved in this inter-laboratory comparison was classified as a function of the technical specification associated with commercial type. The results are presented in Fig. 7 for each aerosol sample. The results are shown separately for the mode diameter and the GSD. The <inline-formula><mml:math id="M49" display="inline"><mml:mi>Z</mml:mi></mml:math></inline-formula> scores are grouped into the four categories represented by different colours, while the contribution of each manufacturer (GRIMM, PALAS, and TSI) is indicated by distinct bar patterns.</p>

      <fig id="F7"><label>Figure 7</label><caption><p id="d2e1625"><inline-formula><mml:math id="M50" display="inline"><mml:mi>Z</mml:mi></mml:math></inline-formula> score calculated for each OPSS tested in the inter-laboratory comparison for the three test aerosols (silica, Spheriglass, Holi powder) as a function of each manufacturer (TSI, PALAS, GRIMM).</p></caption>
          <graphic xlink:href="https://ar.copernicus.org/articles/4/255/2026/ar-4-255-2026-f07.png"/>

        </fig>

      <p id="d2e1641">Overall, optimal or acceptable performances (<inline-formula><mml:math id="M51" display="inline"><mml:mrow><mml:mo>|</mml:mo><mml:mi>Z</mml:mi><mml:msub><mml:mo>|</mml:mo><mml:mrow><mml:msub><mml:mi mathvariant="normal">d</mml:mi><mml:mi mathvariant="normal">mod</mml:mi></mml:msub></mml:mrow></mml:msub><mml:mo>≤</mml:mo><mml:mn mathvariant="normal">2</mml:mn></mml:mrow></mml:math></inline-formula>) are observed for 38 % of instruments involved for silica, 97 % for Spheriglass, and 80 % for the Holi powder samples. Regarding the GSDs (<inline-formula><mml:math id="M52" display="inline"><mml:mrow><mml:mo>|</mml:mo><mml:mi>Z</mml:mi><mml:msub><mml:mo>|</mml:mo><mml:mi mathvariant="normal">GSD</mml:mi></mml:msub><mml:mo>≤</mml:mo><mml:mn mathvariant="normal">2</mml:mn></mml:mrow></mml:math></inline-formula>), these proportions are 58 %, 63 %, and 80 %, respectively. These observations are interesting since the most complex sample, i.e. the Holi powder, does not yield the largest <inline-formula><mml:math id="M53" display="inline"><mml:mi>Z</mml:mi></mml:math></inline-formula> scores. This is due to a greater uncertainty stemming from the multiple measurements performed with the control OPSS <inline-formula><mml:math id="M54" display="inline"><mml:mrow><mml:mi mathvariant="italic">σ</mml:mi><mml:mfenced close=")" open="("><mml:mrow><mml:msub><mml:mi>d</mml:mi><mml:mrow><mml:msub><mml:mi mathvariant="normal">mod</mml:mi><mml:mi mathvariant="normal">OPSS</mml:mi></mml:msub><mml:mo>∗</mml:mo></mml:mrow></mml:msub></mml:mrow></mml:mfenced></mml:mrow></mml:math></inline-formula>, which leads to lower <inline-formula><mml:math id="M55" display="inline"><mml:mi>Z</mml:mi></mml:math></inline-formula> values. On the contrary, the highly repeatable PNSD obtained for monodisperse silica results in larger <inline-formula><mml:math id="M56" display="inline"><mml:mi>Z</mml:mi></mml:math></inline-formula> scores, with a large proportion (62 % for the modal diameter, 42 % for the GSDs) in the questionable and unsatisfactory (<inline-formula><mml:math id="M57" display="inline"><mml:mrow><mml:mo>|</mml:mo><mml:mi>Z</mml:mi><mml:mo>|</mml:mo><mml:mo>&gt;</mml:mo><mml:mn mathvariant="normal">2</mml:mn></mml:mrow></mml:math></inline-formula>) categories linked to the size detection limit of each involved OPSS (180 nm for PALAS and 250–300 nm for GRIMM and TSI; see Table 1). Because the number of specimens involved is not equivalent, the proportions of <inline-formula><mml:math id="M58" display="inline"><mml:mi>Z</mml:mi></mml:math></inline-formula> scores are specified by instrument manufacturer in Fig. 8 for each of the test aerosols considered.</p>

      <fig id="F8"><label>Figure 8</label><caption><p id="d2e1754">Repartition of <inline-formula><mml:math id="M59" display="inline"><mml:mi>Z</mml:mi></mml:math></inline-formula> scores (<inline-formula><mml:math id="M60" display="inline"><mml:mrow><mml:mo>≤</mml:mo><mml:mn mathvariant="normal">2</mml:mn></mml:mrow></mml:math></inline-formula> and <inline-formula><mml:math id="M61" display="inline"><mml:mrow><mml:mo>&gt;</mml:mo><mml:mn mathvariant="normal">2</mml:mn></mml:mrow></mml:math></inline-formula>) for each OPSS manufacturer for the three test aerosols (silica, Spheriglass, Holi powder) for both modal diameter and GSDs.</p></caption>
          <graphic xlink:href="https://ar.copernicus.org/articles/4/255/2026/ar-4-255-2026-f08.png"/>

        </fig>

      <p id="d2e1790">It can be seen from Fig. 8 that <inline-formula><mml:math id="M62" display="inline"><mml:mo>∼</mml:mo></mml:math></inline-formula> 71 % of TSI OPSSs involved in this ILC show optimal or acceptable performances (<inline-formula><mml:math id="M63" display="inline"><mml:mrow><mml:mo>|</mml:mo><mml:mi>Z</mml:mi><mml:msub><mml:mo>|</mml:mo><mml:mrow><mml:msub><mml:mi mathvariant="normal">d</mml:mi><mml:mi mathvariant="normal">mod</mml:mi></mml:msub></mml:mrow></mml:msub><mml:mo>≤</mml:mo><mml:mn mathvariant="normal">2</mml:mn></mml:mrow></mml:math></inline-formula>). This percentage is even better for PALAS devices, with 82 % to 86 % being in the same range of <inline-formula><mml:math id="M64" display="inline"><mml:mi>Z</mml:mi></mml:math></inline-formula> scores for modal diameter and GSDs, respectively. These proportions decrease to 60 % and 40 %, respectively, for the GRIMM instruments. Overall, PALAS OPSSs achieve the best agreement with the control device, whereas GRIMM and, to a lesser extent, TSI show larger deviations. These trends suggest that instrument design and measurement principles play a critical role in performance. Although this was not evident in the <inline-formula><mml:math id="M65" display="inline"><mml:mi>Z</mml:mi></mml:math></inline-formula>-score analysis, the deviations with regards to the control OPSS are particularly important when dealing with heterogeneous and polydisperse particle populations. </p>
      <p id="d2e1838">It was then the intention to seek the dependence between <inline-formula><mml:math id="M66" display="inline"><mml:mi>Z</mml:mi></mml:math></inline-formula> scores and instrumental characteristics. However, the correlation matrix did not reveal a significant effect of any parameter tested (number of size channels, time since last calibration, etc.). It is therefore believed that the biases between measured and control modal diameters are multi-factorial. One question arises regarding the choice of the mobile Fidas as a control instrument, which may have improved the performance evaluation of other PALAS devices. This choice was mainly motivated by the higher size channel resolutions of PALAS OPSSs compared to the other types (Table 1). The size dependence and variability of the scattered-light intensity in relation to particle morphology and refractive index influence the performances of OPSSs (Szymanski et al., 2009). Other parameters can also impact the measured pulse height spectrum of OPSSs, such as the coincidence due to the presence of more than one particle in the sensing volume and the inability of the electronic system to process such events. These limitations may affect the comparability of results between different OPSS types which are usually calibrated by the manufacturers or, less frequently, by users. Calibration of OPSSs can also be used to characterise the instrument correlation to particles with different refractive indices and morphologies from those of calibration particles (Szymanski and Liu, 1986). In terms of particle size and number concentration, Marple and Rubow (1976) calibrated an OPSS with respect to aerodynamic particle size using cascade impactors, which appears to be a time-consuming methodology. Other approaches were also developed using cyclones and filters on the OPSS inlet. Comparisons to aerodynamic particle sizers, scanning mobility particle sizers, and/or electron microscopy measurements were also performed (Binnig et al., 2007; Sousan et al., 2016). In that way,  Sang-Nourpour and Olfert (2019) developed a new calibration technique involving an aerodynamic aerosol classifier (AAC) coupled to an OPSS to be tested for the size calibration and to a condensation particle counter for the number concentration. Their protocol presents the advantage of not being limited to a specific particle material or aerosol generation method. Among the parameters that may be at the origin of the deviations observed in relation to the control measurement, the degree of expertise of the operator in charge of the tests and the time since the last calibration and/or maintenance of the device are to be considered. It is therefore difficult to pinpoint a single parameter responsible for the observed deviations between instruments and to propose a further set of good laboratory practices. Depending on the aerosol concentration used during the experiments carried out by each partner, coincidence effects can have disproportionately affected measurements. Instrument-specific factors, including differences in size channel resolution, calibration history, operator expertise, and time since last maintenance, further complicate comparability and interpretation. Because OPSS devices are typically calibrated with reference particles whose optical properties do not match those of the test aerosols, these differences likely introduce significant biases into the particle size measurement, highlighting the challenges of achieving precise inter-laboratory agreement.</p>
</sec>
</sec>
<sec id="Ch1.S4">
  <label>4</label><title>Discussion and perspectives</title>
      <p id="d2e1857">This inter-laboratory comparison provides a comprehensive assessment of the metrological performance of OPSSs for measuring particle number size distributions across a range of aerosols without the intention of generating specific test aerosols. This study provided an opportunity to bring together a large number of partners at the national level on a topic that still requires further scientific investigation, especially regarding the access to an affordable and widely deployable calibration bench for multiple laboratories. The standardisation framework associated with OPSS calibration is highly complex, involving stringent requirements with specialised and non-portable facilities. In this context, the present study aimed to develop a common experimental set-up that is straightforward to implement, easily transportable, and highly versatile. Indeed, the system was designed to accommodate a wide range of test aerosols, enabling the generation of polydisperse aerosols in the micron size range, including solid and spherical aerosols. Such flexibility is particularly challenging to achieve with wet-generation systems, which are typically less adaptable and more constrained in terms of aerosol type and operating conditions.</p>
      <p id="d2e1860">The study involved 16 research groups and 35 OPSSs of various types, tested on three aerosol samples: monodisperse amorphous silica, glass beads, and green Holi powder. This originality lies in the fact that, despite using the same aerosol, the same generator, the same control measurement device, the same experimental protocol, and the OPSS instruments from each participating laboratory, the reported results still differed in several cases. For the monodisperse silica sample, measurements were within <inline-formula><mml:math id="M67" display="inline"><mml:mrow><mml:mo>±</mml:mo><mml:mn mathvariant="normal">30</mml:mn></mml:mrow></mml:math></inline-formula> % of the control OPSS, reflecting the high comparability of instruments for narrow size distributions. However, greater variability was observed for the glass beads and Holi powder, which exhibited broader size distributions and complex particle morphologies. When looking at the modal diameter provided by the different OPSSs, 72 % of the instruments were in optimal or acceptable <inline-formula><mml:math id="M68" display="inline"><mml:mi>Z</mml:mi></mml:math></inline-formula>-score zones (71 %, 82 %, and 60 % for TSI, PALAS, and GRIMM devices, respectively). Two thirds of the GSDs obtained by means of lognormal fit were found in the same range of <inline-formula><mml:math id="M69" display="inline"><mml:mi>Z</mml:mi></mml:math></inline-formula> scores: 75 % for TSI, 86 % for PALAS, and 40 % for GRIMM instruments.</p>
      <p id="d2e1887">Although most measurements clustered near the control, outliers highlighted systematic deviations linked to factors such as calibration history, size channel resolution, particle morphology, and refractive index differences between calibration standards and test aerosols. Such properties are particularly difficult to determine, especially when complex particles are involved. Nonetheless, this study offers an essential starting point for future work that will need to address the more advanced calibration approaches and to further investigate how such methods could be implemented in practice. Coincidence effects due to higher aerosol concentrations during partner experiments were also identified as contributing to measurement variability, even if each participant was asked to make sure that each OPSS involved was used under “good laboratory practice” conditions, i.e. by ensuring the absence of internal errors reported by the devices, including coincidence errors.</p>
      <p id="d2e1890">These results confirm that, while OPSSs provide generally reliable PNSD measurements, the observed inter-instrument deviations emphasise the complexity of ensuring consistent performance across laboratories. This study establishes both a methodology and a first dataset for improving OPSS reliability at national and international scales. It underlines the need for strengthened robustness in aerosol measurements and for a clearer understanding of the sources of variability when instruments are deployed under routine monitoring conditions. Although the ISO 21501 standard provides essential requirements for the calibration and performance verification of optical particle counters under controlled laboratory conditions, it does not comprehensively address the influence of complex aerosol properties encountered during ambient or operational measurements, such as non-sphericity, particle agglomeration, variable refractive indices, or broad polydisperse size distributions. Therefore, future work focusing on harmonising calibration procedures using aerosols that better represent real-world optical properties, correcting for coincidence errors, and standardising best practices for instrument maintenance and data acquisition is still needed. Expanding inter-laboratory comparisons to include a broader range of particle types, sizes, and concentrations will further strengthen confidence in OPSS measurements, supporting more accurate and timely air quality monitoring.</p>
</sec>

      
      </body>
    <back><notes notes-type="codedataavailability"><title>Code and data availability</title>

      <p id="d2e1898">Experimental data can be made available upon request from the corresponding author. Due to confidentiality agreements involving several partners who contributed to this study as co-authors, the datasets generated and analysed during this study cannot be made publicly available. The data contain sensitive information subject to contractual and proprietary restrictions, and their disclosure could compromise partner confidentiality obligations. In addition, the processing and analysis of the dataset were performed using proprietary workflows developed in Origin software (OriginPro 2023), making the data structure and processing pipeline difficult to transfer, reproduce, or use outside the original working environment. Therefore, access to the data cannot be provided publicly or upon request.</p>
  </notes><notes notes-type="authorcontribution"><title>Author contributions</title>

      <p id="d2e1904">SB and FGL conceived and designed this study from scientific, technical, and partnership perspectives. SB was primarily involved in data processing, while FGL focused on the dissemination and valorisation of the results. All partners contributed to the work according to a defined timeline, including the provision and use of the generator, and the project was carried out without dedicated funding.</p>
  </notes><notes notes-type="competinginterests"><title>Competing interests</title>

      <p id="d2e1910">The contact author has declared that none of the authors has any competing interests.</p>
  </notes><notes notes-type="disclaimer"><title>Disclaimer</title>

      <p id="d2e1916">Publisher's note: Copernicus Publications remains neutral with regard to jurisdictional claims made in the text, published maps, institutional affiliations, or any other geographical representation in this paper. The authors bear the ultimate responsibility for providing appropriate place names. Views expressed in the text are those of the authors and do not necessarily reflect the views of the publisher.</p>
  </notes><ack><title>Acknowledgements</title><p id="d2e1922">The authors would like to acknowledge the ASFERA (Association française d'études et de recherches sur les aérosols) for its support and assistance in partner identification.</p></ack><notes notes-type="reviewstatement"><title>Review statement</title>

      <p id="d2e1927">This paper was edited by Christof Asbach and reviewed by three anonymous referees.</p>
  </notes><ref-list>
    <title>References</title>

      <ref id="bib1.bib1"><label>1</label><mixed-citation>Binnig, J., Meyer, J., and Kasper, G.: Calibration of an optical particle counter to provide PM<sub>2.5</sub> mass for well-defined particle materials, J. Aerosol Sci., 38, 325–332, <ext-link xlink:href="https://doi.org/10.1016/j.jaerosci.2006.12.001" ext-link-type="DOI">10.1016/j.jaerosci.2006.12.001</ext-link>, 2007. </mixed-citation></ref>
      <ref id="bib1.bib2"><label>2</label><mixed-citation>Gaie-Levrel, F., Bourrous, S., and Macé, T.: Development of a portable reference aerosol generator (PRAG) for calibration of particle mass concentration measurements, Particuology, 37, 134–142, <ext-link xlink:href="https://doi.org/10.1016/j.partic.2017.06.005" ext-link-type="DOI">10.1016/j.partic.2017.06.005</ext-link>, 2018.</mixed-citation></ref>
      <ref id="bib1.bib3"><label>3</label><mixed-citation>Gaie-Levrel, F., Bau, S., Bregonzio-Rozier, L., Payet, R., Artous, S., Jacquinot, S., Guiot, A., Ouf, F. X., Bourrous, S., Marpillat, A., Foulquier, C., Smith, G., Crenn, V., and Feltin, N.: An intercomparison exercise of good laboratory practices for nano-aerosol size measurements by mobility spectrometers, J. Nanopart. Res., 22, 103-, <ext-link xlink:href="https://doi.org/10.1007/s11051-020-04820-y" ext-link-type="DOI">10.1007/s11051-020-04820-y</ext-link>, 2020.</mixed-citation></ref>
      <ref id="bib1.bib4"><label>4</label><mixed-citation>Hindman Ii, E. E., Trusty, G. L., Hudson, J. G., Fitzgerald, J. W., and Rogersi, C. F.: Field comparison of optical particle counters, Atmo. Environ., 12,  1195–1200, <ext-link xlink:href="https://doi.org/10.1016/0004-6981(78)90367-0" ext-link-type="DOI">10.1016/0004-6981(78)90367-0</ext-link>, 1978.</mixed-citation></ref>
      <ref id="bib1.bib5"><label>5</label><mixed-citation>Horender, S., Auderset, K., and Vasilatou, K.: Facility for calibration of optical and condensation particle counters based on a turbulent aerosol mixing tube and a reference optical particle counter, Rev. Sci. Inst., 90, <ext-link xlink:href="https://doi.org/10.1063/1.5095853" ext-link-type="DOI">10.1063/1.5095853</ext-link>, 2019.</mixed-citation></ref>
      <ref id="bib1.bib6"><label>6</label><mixed-citation>Hubert, P., Herbin, H., Visez, N., Pujol, O., and Petitprez, D.: New approach for the determination of aerosol refractive indices – Part II: Experimental set-up and application to amorphous silica particles, J. Quant. Spectrosc. Ra., 200, 320–327, <ext-link xlink:href="https://doi.org/10.1016/j.jqsrt.2017.03.037" ext-link-type="DOI">10.1016/j.jqsrt.2017.03.037</ext-link>, 2017.</mixed-citation></ref>
      <ref id="bib1.bib7"><label>7</label><mixed-citation>Iida, K. and Sakurai, H.: Counting efficiency evaluation of optical particle counters in micrometer range by using an inkjet aerosol generator, Aerosol Sci. Technol., 52, 1156–1166, <ext-link xlink:href="https://doi.org/10.1080/02786826.2018.1505032" ext-link-type="DOI">10.1080/02786826.2018.1505032</ext-link>, 2018.</mixed-citation></ref>
      <ref id="bib1.bib8"><label>8</label><mixed-citation>ISO 13528: Statistical methods for use in proficiency testing by interlaboratory comparison, <uri>https://www.iso.org/standard/78879.html</uri> (last access: 10 June 2026),  2022.</mixed-citation></ref>
      <ref id="bib1.bib9"><label>9</label><mixed-citation>ISO 21501-1: Determination of particle size distribution – Single particle light interaction methods – Part 1: Light scattering aerosol spectrometer,  <uri>https://cobaz.afnor.org/notice/norme/iso-21501-12025/XS146596?rechercheID=44163013&amp;searchIndex=2&amp;activeTab=all</uri> (last access: 10 June 2026), 2025.</mixed-citation></ref>
      <ref id="bib1.bib10"><label>10</label><mixed-citation>ISO 21501-4: Determination of Particle Size Distribution – Single Particle Light Interaction Methods – Part 4: Light Scattering Airborne Particle Counter for Clean Spaces,  <uri>https://cobaz.afnor.org/notice/norme/iso-21501-42018/XS127973?rechercheID=27531797&amp;searchIndex=1&amp;activeTab=all</uri> (last access: 10 June 2026), 2018.</mixed-citation></ref>
      <ref id="bib1.bib11"><label>11</label><mixed-citation>Leglise, J., Crenn, V., Le Dur, D., and Gensdarmes, F.: Vers un passage au TRL 8 d'un disperseur de poudre de type vortex shaker, ASFERA, <ext-link xlink:href="https://doi.org/10.25576/ASFERA-CFA2022-28366" ext-link-type="DOI">10.25576/ASFERA-CFA2022-28366</ext-link>, 2022.</mixed-citation></ref>
      <ref id="bib1.bib12"><label>12</label><mixed-citation>Maragkidou, A., Jaghbeir, O., Hämeri, K., and Hussein, T.: Aerosol particles (0.3–10 <inline-formula><mml:math id="M71" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">µ</mml:mi></mml:mrow></mml:math></inline-formula>m) inside an educational workshop – Emission rate and inhaled deposited dose, Build. Environ., 140, 80–89, <ext-link xlink:href="https://doi.org/10.1016/j.buildenv.2018.05.031" ext-link-type="DOI">10.1016/j.buildenv.2018.05.031</ext-link>, 2018.</mixed-citation></ref>
      <ref id="bib1.bib13"><label>13</label><mixed-citation>Marple, V. A. and Rubow, K. L.: Aerodynamic particle size calibration of optical particle counters, J. Aerosol Sci.,  7, 425–433, <ext-link xlink:href="https://doi.org/10.1016/0021-8502(76)90028-8" ext-link-type="DOI">10.1016/0021-8502(76)90028-8</ext-link>, 1976.</mixed-citation></ref>
      <ref id="bib1.bib14"><label>14</label><mixed-citation>Mishchenko, M. I., Travis, L. D., and Lacis, A. A.: Scattering, Absorption, and Emission of Light by Small Particles, Cambridge University Press, <uri>https://books.google.com/books/about/Scattering_Absorption_and_Emission_of_Li.html?hl=fr&amp;id=i6r1YFyK_g8C</uri> (last access:  10 June 2026), 2002.</mixed-citation></ref>
      <ref id="bib1.bib15"><label>15</label><mixed-citation>Ortega, J., Snider, J. R., Smith, J. N., and Reeves, J. M.: Comparison of aerosol measurement systems during the 2016 airborne ARISTO campaign, Aerosol Sci. Technol., 53, 871–885, <ext-link xlink:href="https://doi.org/10.1080/02786826.2019.1610554" ext-link-type="DOI">10.1080/02786826.2019.1610554</ext-link>, 2019.</mixed-citation></ref>
      <ref id="bib1.bib16"><label>16</label><mixed-citation>R'Mili, B., Le Bihan, O. L. C., Dutouquet, C., Aguerre-Charriol, O., and Frejafon, E.: Particle sampling by TEM grid filtration, Aerosol Sci. Technol., 47, 767–775, <ext-link xlink:href="https://doi.org/10.1080/02786826.2013.789478" ext-link-type="DOI">10.1080/02786826.2013.789478</ext-link>, 2013.</mixed-citation></ref>
      <ref id="bib1.bib17"><label>17</label><mixed-citation>Sang-Nourpour, N. and Olfert, J. S.: Calibration of optical particle counters with an aerodynamic aerosol classifier, J. Aerosol Sci., 138, <ext-link xlink:href="https://doi.org/10.1016/j.jaerosci.2019.105452" ext-link-type="DOI">10.1016/j.jaerosci.2019.105452</ext-link>, 2019.</mixed-citation></ref>
      <ref id="bib1.bib18"><label>18</label><mixed-citation>Sousan, S., Koehler, K., Hallett, L., and Peters, T. M.: Evaluation of the Alphasense optical particle counter (OPC-N2) and the Grimm portable aerosol spectrometer (PAS-1.108), Aerosol Sci. Technol., 50, 1352–1365, <ext-link xlink:href="https://doi.org/10.1080/02786826.2016.1232859" ext-link-type="DOI">10.1080/02786826.2016.1232859</ext-link>, 2016.</mixed-citation></ref>
      <ref id="bib1.bib19"><label>19</label><mixed-citation>Szymanski, W. W. and Liu, B. Y. H.: On the Sizing Accuracy of Laser Optical Particle Counters, Particle &amp; Particle Systems Characterization, 3, 1–7, <ext-link xlink:href="https://doi.org/10.1002/ppsc.19860030102" ext-link-type="DOI">10.1002/ppsc.19860030102</ext-link>,  1986.</mixed-citation></ref>
      <ref id="bib1.bib20"><label>20</label><mixed-citation>Szymanski, W. W., Nagy, A., and Czitrovszky, A.: Optical particle spectrometry-Problems and prospects, J. Quant. Spectrosc. Ra., 110, 918–929, <ext-link xlink:href="https://doi.org/10.1016/j.jqsrt.2009.02.024" ext-link-type="DOI">10.1016/j.jqsrt.2009.02.024</ext-link>, July 2009.</mixed-citation></ref>
      <ref id="bib1.bib21"><label>21</label><mixed-citation>Thompson, M., Ellison, S. L. R., and Wood, R.: The International Harmonized Protocol for the proficiency testing of analytical chemistry laboratories: (IUPAC technical report), Pure Appl. Chem., 78, 145–196, <ext-link xlink:href="https://doi.org/10.1351/pac200678010145" ext-link-type="DOI">10.1351/pac200678010145</ext-link>, 2006.</mixed-citation></ref>
      <ref id="bib1.bib22"><label>22</label><mixed-citation>Vasilatou, K., Dirscherl, K., Iida, K., Sakurai, H., Horender, S., and Auderset, K.: Calibration of optical particle counters: First comprehensive inter-comparison for particle sizes up to 5 <inline-formula><mml:math id="M72" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">µ</mml:mi></mml:mrow></mml:math></inline-formula>m and number concentrations up to 2 cm<sup>−3</sup>, Metrologia, 57, <ext-link xlink:href="https://doi.org/10.1088/1681-7575/ab5c84" ext-link-type="DOI">10.1088/1681-7575/ab5c84</ext-link>, 2020.</mixed-citation></ref>
      <ref id="bib1.bib23"><label>23</label><mixed-citation>Xiang, M., Morgeneyer, M., Aguerre-Chariol, O., Philippe, F., and Bressot, C.: Airborne nanoparticle collection efficiency of a TEM grid-equipped sampling system, Aerosol Sci. Technol., 55, 526–538, <ext-link xlink:href="https://doi.org/10.1080/02786826.2020.1870923" ext-link-type="DOI">10.1080/02786826.2020.1870923</ext-link>, 2021.</mixed-citation></ref>

  </ref-list></back>
    <!--<article-title-html>An intercomparison study of optical particle size spectrometers for aerosol number size  distribution measurements</article-title-html>
<abstract-html/>
<ref-html id="bib1.bib1"><label>1</label><mixed-citation>
      
Binnig, J., Meyer, J., and Kasper, G.: Calibration of an optical particle
counter to provide PM<sub>2.5</sub> mass for well-defined particle materials, J.
Aerosol Sci., 38, 325–332, <a href="https://doi.org/10.1016/j.jaerosci.2006.12.001" target="_blank">https://doi.org/10.1016/j.jaerosci.2006.12.001</a>,
2007.


    </mixed-citation></ref-html>
<ref-html id="bib1.bib2"><label>2</label><mixed-citation>
      
Gaie-Levrel, F., Bourrous, S., and Macé, T.: Development of a portable
reference aerosol generator (PRAG) for calibration of particle mass
concentration measurements, Particuology, 37, 134–142,
<a href="https://doi.org/10.1016/j.partic.2017.06.005" target="_blank">https://doi.org/10.1016/j.partic.2017.06.005</a>, 2018.

    </mixed-citation></ref-html>
<ref-html id="bib1.bib3"><label>3</label><mixed-citation>
      
Gaie-Levrel, F., Bau, S., Bregonzio-Rozier, L., Payet, R., Artous, S.,
Jacquinot, S., Guiot, A., Ouf, F. X., Bourrous, S., Marpillat, A.,
Foulquier, C., Smith, G., Crenn, V., and Feltin, N.: An intercomparison
exercise of good laboratory practices for nano-aerosol size measurements by
mobility spectrometers, J. Nanopart. Res., 22,
103-, <a href="https://doi.org/10.1007/s11051-020-04820-y" target="_blank">https://doi.org/10.1007/s11051-020-04820-y</a>, 2020.

    </mixed-citation></ref-html>
<ref-html id="bib1.bib4"><label>4</label><mixed-citation>
      
Hindman Ii, E. E., Trusty, G. L., Hudson, J. G., Fitzgerald, J. W., and
Rogersi, C. F.: Field comparison of optical particle counters, Atmo. Environ., 12,  1195–1200, <a href="https://doi.org/10.1016/0004-6981(78)90367-0" target="_blank">https://doi.org/10.1016/0004-6981(78)90367-0</a>, 1978.

    </mixed-citation></ref-html>
<ref-html id="bib1.bib5"><label>5</label><mixed-citation>
      
Horender, S., Auderset, K., and Vasilatou, K.: Facility for calibration of
optical and condensation particle counters based on a turbulent aerosol
mixing tube and a reference optical particle counter, Rev. Sci.
Inst., 90, <a href="https://doi.org/10.1063/1.5095853" target="_blank">https://doi.org/10.1063/1.5095853</a>, 2019.

    </mixed-citation></ref-html>
<ref-html id="bib1.bib6"><label>6</label><mixed-citation>
      
Hubert, P., Herbin, H., Visez, N., Pujol, O., and Petitprez, D.: New
approach for the determination of aerosol refractive indices – Part II:
Experimental set-up and application to amorphous silica particles, J. Quant.
Spectrosc. Ra., 200, 320–327,
<a href="https://doi.org/10.1016/j.jqsrt.2017.03.037" target="_blank">https://doi.org/10.1016/j.jqsrt.2017.03.037</a>, 2017.

    </mixed-citation></ref-html>
<ref-html id="bib1.bib7"><label>7</label><mixed-citation>
      
Iida, K. and Sakurai, H.: Counting efficiency evaluation of optical particle
counters in micrometer range by using an inkjet aerosol generator, Aerosol
Sci. Technol., 52, 1156–1166,
<a href="https://doi.org/10.1080/02786826.2018.1505032" target="_blank">https://doi.org/10.1080/02786826.2018.1505032</a>, 2018.

    </mixed-citation></ref-html>
<ref-html id="bib1.bib8"><label>8</label><mixed-citation>
      
ISO 13528: Statistical methods for use in proficiency testing by
interlaboratory comparison, <a href="https://www.iso.org/standard/78879.html" target="_blank"/> (last access: 10 June 2026),  2022.

    </mixed-citation></ref-html>
<ref-html id="bib1.bib9"><label>9</label><mixed-citation>
      
ISO 21501-1: Determination of particle size distribution – Single particle light interaction methods – Part 1: Light scattering aerosol spectrometer,  <a href="https://cobaz.afnor.org/notice/norme/iso-21501-12025/XS146596?rechercheID=44163013&amp;searchIndex=2&amp;activeTab=all" target="_blank"/> (last access: 10 June 2026), 2025.

    </mixed-citation></ref-html>
<ref-html id="bib1.bib10"><label>10</label><mixed-citation>
      
ISO 21501-4: Determination of Particle Size Distribution – Single Particle
Light Interaction Methods – Part 4: Light Scattering Airborne Particle
Counter for Clean Spaces,  <a href="https://cobaz.afnor.org/notice/norme/iso-21501-42018/XS127973?rechercheID=27531797&amp;searchIndex=1&amp;activeTab=all" target="_blank"/> (last access: 10 June 2026), 2018.

    </mixed-citation></ref-html>
<ref-html id="bib1.bib11"><label>11</label><mixed-citation>
      
Leglise, J., Crenn, V., Le Dur, D., and Gensdarmes, F.: Vers un passage au
TRL 8 d'un disperseur de poudre de type vortex shaker, ASFERA,
<a href="https://doi.org/10.25576/ASFERA-CFA2022-28366" target="_blank">https://doi.org/10.25576/ASFERA-CFA2022-28366</a>, 2022.

    </mixed-citation></ref-html>
<ref-html id="bib1.bib12"><label>12</label><mixed-citation>
      
Maragkidou, A., Jaghbeir, O., Hämeri, K., and Hussein, T.: Aerosol
particles (0.3–10&thinsp;µm) inside an educational workshop – Emission rate
and inhaled deposited dose, Build. Environ., 140, 80–89,
<a href="https://doi.org/10.1016/j.buildenv.2018.05.031" target="_blank">https://doi.org/10.1016/j.buildenv.2018.05.031</a>, 2018.

    </mixed-citation></ref-html>
<ref-html id="bib1.bib13"><label>13</label><mixed-citation>
      
Marple, V. A. and Rubow, K. L.: Aerodynamic particle size calibration of optical particle counters, J. Aerosol Sci.,  7, 425–433, <a href="https://doi.org/10.1016/0021-8502(76)90028-8" target="_blank">https://doi.org/10.1016/0021-8502(76)90028-8</a>,
1976.

    </mixed-citation></ref-html>
<ref-html id="bib1.bib14"><label>14</label><mixed-citation>
      
Mishchenko, M. I., Travis, L. D., and Lacis, A. A.: Scattering, Absorption,
and Emission of Light by Small Particles, Cambridge University Press, <a href="https://books.google.com/books/about/Scattering_Absorption_and_Emission_of_Li.html?hl=fr&amp;id=i6r1YFyK_g8C" target="_blank"/> (last access:  10 June 2026), 2002.

    </mixed-citation></ref-html>
<ref-html id="bib1.bib15"><label>15</label><mixed-citation>
      
Ortega, J., Snider, J. R., Smith, J. N., and Reeves, J. M.: Comparison of
aerosol measurement systems during the 2016 airborne ARISTO campaign,
Aerosol Sci. Technol., 53, 871–885,
<a href="https://doi.org/10.1080/02786826.2019.1610554" target="_blank">https://doi.org/10.1080/02786826.2019.1610554</a>, 2019.

    </mixed-citation></ref-html>
<ref-html id="bib1.bib16"><label>16</label><mixed-citation>
      
R'Mili, B., Le Bihan, O. L. C., Dutouquet, C., Aguerre-Charriol, O., and
Frejafon, E.: Particle sampling by TEM grid filtration, Aerosol Sci.
Technol., 47, 767–775, <a href="https://doi.org/10.1080/02786826.2013.789478" target="_blank">https://doi.org/10.1080/02786826.2013.789478</a>,
2013.

    </mixed-citation></ref-html>
<ref-html id="bib1.bib17"><label>17</label><mixed-citation>
      
Sang-Nourpour, N. and Olfert, J. S.: Calibration of optical particle
counters with an aerodynamic aerosol classifier, J. Aerosol Sci., 138,
<a href="https://doi.org/10.1016/j.jaerosci.2019.105452" target="_blank">https://doi.org/10.1016/j.jaerosci.2019.105452</a>, 2019.

    </mixed-citation></ref-html>
<ref-html id="bib1.bib18"><label>18</label><mixed-citation>
      
Sousan, S., Koehler, K., Hallett, L., and Peters, T. M.: Evaluation of the
Alphasense optical particle counter (OPC-N2) and the Grimm portable aerosol
spectrometer (PAS-1.108), Aerosol Sci. Technol., 50, 1352–1365,
<a href="https://doi.org/10.1080/02786826.2016.1232859" target="_blank">https://doi.org/10.1080/02786826.2016.1232859</a>, 2016.

    </mixed-citation></ref-html>
<ref-html id="bib1.bib19"><label>19</label><mixed-citation>
      
Szymanski, W. W. and Liu, B. Y. H.: On the Sizing Accuracy of Laser Optical
Particle Counters, Particle &amp; Particle Systems Characterization, 3, 1–7, <a href="https://doi.org/10.1002/ppsc.19860030102" target="_blank">https://doi.org/10.1002/ppsc.19860030102</a>,  1986.

    </mixed-citation></ref-html>
<ref-html id="bib1.bib20"><label>20</label><mixed-citation>
      
Szymanski, W. W., Nagy, A., and Czitrovszky, A.: Optical particle
spectrometry-Problems and prospects, J. Quant. Spectrosc. Ra., 110, 918–929,
<a href="https://doi.org/10.1016/j.jqsrt.2009.02.024" target="_blank">https://doi.org/10.1016/j.jqsrt.2009.02.024</a>, July 2009.

    </mixed-citation></ref-html>
<ref-html id="bib1.bib21"><label>21</label><mixed-citation>
      
Thompson, M., Ellison, S. L. R., and Wood, R.: The International Harmonized
Protocol for the proficiency testing of analytical chemistry laboratories:
(IUPAC technical report), Pure Appl. Chem., 78, 145–196,
<a href="https://doi.org/10.1351/pac200678010145" target="_blank">https://doi.org/10.1351/pac200678010145</a>, 2006.

    </mixed-citation></ref-html>
<ref-html id="bib1.bib22"><label>22</label><mixed-citation>
      
Vasilatou, K., Dirscherl, K., Iida, K., Sakurai, H., Horender, S., and
Auderset, K.: Calibration of optical particle counters: First comprehensive
inter-comparison for particle sizes up to 5&thinsp;µm and number
concentrations up to 2&thinsp;cm<sup>−3</sup>, Metrologia, 57,
<a href="https://doi.org/10.1088/1681-7575/ab5c84" target="_blank">https://doi.org/10.1088/1681-7575/ab5c84</a>, 2020.

    </mixed-citation></ref-html>
<ref-html id="bib1.bib23"><label>23</label><mixed-citation>
      
Xiang, M., Morgeneyer, M., Aguerre-Chariol, O., Philippe, F., and Bressot,
C.: Airborne nanoparticle collection efficiency of a TEM grid-equipped
sampling system, Aerosol Sci. Technol., 55, 526–538,
<a href="https://doi.org/10.1080/02786826.2020.1870923" target="_blank">https://doi.org/10.1080/02786826.2020.1870923</a>, 2021.