Articles | Volume 4, issue 1
https://doi.org/10.5194/ar-4-121-2026
https://doi.org/10.5194/ar-4-121-2026
Research article
 | 
03 Mar 2026
Research article |  | 03 Mar 2026

Evaluation of mass measurement techniques for soot with different size distributions and OC ∕ TC contents

Benoît Sagot, Guillaume Pailloux, and Amel Kort

Download

Interactive discussion

Status: closed

Comment types: AC – author | RC – referee | CC – community | EC – editor | CEC – chief editor | : Report abuse
  • RC1: 'Comment on ar-2025-15', Anonymous Referee #1, 11 Jun 2025
    • AC1: 'Reply on RC1', Benoit Sagot, 06 Aug 2025
  • RC2: 'Comment on ar-2025-15', Anonymous Referee #2, 26 Jun 2025
    • AC2: 'Reply on RC2', Benoit Sagot, 06 Aug 2025
  • RC3: 'Comment on ar-2025-15', Anonymous Referee #3, 27 Jun 2025
    • AC3: 'Reply on RC3', Benoit Sagot, 06 Aug 2025

Peer review completion

AR – Author's response | RR – Referee report | ED – Editor decision | EF – Editorial file upload
AR by Benoit Sagot on behalf of the Authors (06 Aug 2025)  Author's response 
EF by Polina Shvedko (26 Aug 2025)  Manuscript   Author's tracked changes 
ED: Referee Nomination & Report Request started (08 Sep 2025) by Attila Nagy
RR by Anonymous Referee #2 (25 Sep 2025)
RR by Anonymous Referee #3 (26 Sep 2025)
RR by Anonymous Referee #1 (10 Nov 2025)
ED: Reconsider after major revisions (10 Nov 2025) by Attila Nagy
AR by Benoit Sagot on behalf of the Authors (19 Dec 2025)  Author's response   Author's tracked changes   Manuscript 
ED: Referee Nomination & Report Request started (03 Jan 2026) by Attila Nagy
RR by Anonymous Referee #3 (20 Jan 2026)
ED: Publish subject to minor revisions (review by editor) (23 Jan 2026) by Attila Nagy
AR by Benoit Sagot on behalf of the Authors (30 Jan 2026)  Author's response   Author's tracked changes 
EF by Polina Shvedko (30 Jan 2026)  Manuscript 
ED: Publish as is (10 Feb 2026) by Attila Nagy
AR by Benoit Sagot on behalf of the Authors (11 Feb 2026)  Author's response   Manuscript 
Download
Short summary
The measurement of particle mass concentrations in gases is essential for monitoring emissions from engine exhaust or atmospheric pollutants. Various instruments allow for real-time concentration monitoring, but few studies have evaluated the accuracy and reliability of these measurements. We present the results of an intercomparison between several mass concentration measurement instruments to assess their ranges of validity, providing valuable guidance for future users of these devices.
Share
Altmetrics
Final-revised paper
Preprint